The detection instrumentation and geometric design of clinical PET scanner: towards better performance and broader clinical applications

被引:0
|
作者
El Ouaridi, Abdallah [1 ]
Elcadi, Zakaria Ait [1 ,2 ]
Mkimel, Mounir [1 ]
Bougteb, Mustapha [1 ]
El Baydaoui, Redouane [1 ]
机构
[1] Hassan First Univ Settat, High Inst Hlth Sci, Lab Hlth Sci & Technol, Settat, Morocco
[2] Texas A&M Univ Qatar, Elect & Comp Engn, Doha 23874, Qatar
关键词
positron emission tomography; PET instrumentation; PET performance; clinical application; TIME-OF-FLIGHT; POSITRON-EMISSION-TOMOGRAPHY; MONTE-CARLO-SIMULATION; COUNT-RATE PERFORMANCE; EXTENDED AXIAL-FIELD; SILICON-PHOTOMULTIPLIER; TOF-PET; SCINTILLATION PROPERTIES; IMAGING PERFORMANCE; BISMUTH-GERMANATE;
D O I
10.1088/2057-1976/ad2d61
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Positron emission tomography (PET) is a powerful medical imaging modality used in nuclear medicine to diagnose and monitor various clinical diseases in patients. It is more sensitive and produces a highly quantitative mapping of the three-dimensional biodistribution of positron-emitting radiotracers inside the human body. The underlying technology is constantly evolving, and recent advances in detection instrumentation and PET scanner design have significantly improved the medical diagnosis capabilities of this imaging modality, making it more efficient and opening the way to broader, innovative, and promising clinical applications. Some significant achievements related to detection instrumentation include introducing new scintillators and photodetectors as well as developing innovative detector designs and coupling configurations. Other advances in scanner design include moving towards a cylindrical geometry, 3D acquisition mode, and the trend towards a wider axial field of view and a shorter diameter. Further research on PET camera instrumentation and design will be required to advance this technology by improving its performance and extending its clinical applications while optimising radiation dose, image acquisition time, and manufacturing cost. This article comprehensively reviews the various parameters of detection instrumentation and PET system design. Firstly, an overview of the historical innovation of the PET system has been presented, focusing on instrumental technology. Secondly, we have characterised the main performance parameters of current clinical PET and detailed recent instrumental innovations and trends that affect these performances and clinical practice. Finally, prospects for this medical imaging modality are presented and discussed. This overview of the PET system's instrumental parameters enables us to draw solid conclusions on achieving the best possible performance for the different needs of different clinical applications.
引用
收藏
页数:23
相关论文
共 38 条
  • [31] Clinical performance of 68Ga-PSMA-11 PET/MRI for the detection of recurrent prostate cancer following radical prostatectomy
    Benedikt Kranzbühler
    Hannes Nagel
    Anton S. Becker
    Julian Müller
    Martin Huellner
    Paul Stolzmann
    Urs Muehlematter
    Matthias Guckenberger
    Philipp A. Kaufmann
    Daniel Eberli
    Irene A. Burger
    European Journal of Nuclear Medicine and Molecular Imaging, 2018, 45 : 20 - 30
  • [32] SERS immuno- and apta-assays in biosensing/bio-detection: Performance comparison, clinical applications, challenges
    Ilyas, Aisha
    Dyussupova, Aigerim
    Sultangaziyev, Alisher
    Shevchenko, Yegor
    Filchakova, Olena
    Bukasov, Rostislav
    TALANTA, 2023, 265
  • [33] Clinical performance and utility: A microsimulation model to inform the design of screening trials for a multi-cancer early detection test
    Dai, James Y.
    Zhang, Jing
    Braun, Jerome, V
    Simon, Noah
    Hubbell, Earl
    Zhang, Nan
    JOURNAL OF MEDICAL SCREENING, 2024, 31 (03) : 140 - 149
  • [34] Performance of Copy Number Variant Detection from ShortRead Whole-Genome Sequencing for Clinical Gene-Panel Applications
    De La Vega, F.
    Anur, P.
    Han, J.
    Han, S.
    Irvine, S.
    Kang, P.
    Kraft, L.
    Lee, Y.
    Onuchic, V.
    Potts, K.
    Torres, R.
    Truong, S.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2023, 25 (11): : S147 - S147
  • [35] Design and Performance of a 1 mm3 Resolution Clinical PET System Comprising 3-D Position Sensitive Scintillation Detectors
    Hsu, David F. C.
    Freese, David L.
    Reynolds, Paul D.
    Innes, Derek R.
    Levin, Craig S.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2018, 37 (04) : 1058 - 1066
  • [36] The effects of various penalty parameter values in Q.Clear algorithm for rectal cancer detection on 18F-FDG images using a BGO-based PET/CT scanner: a phantom and clinical study
    Sadeghi, Fatemeh
    Sheikhzadeh, Peyman
    Farzanehfar, Saeed
    Ghafarian, Pardis
    Moafpurian, Yalda
    Ay, Mohammadreza
    EJNMMI PHYSICS, 2023, 10 (01)
  • [37] The effects of various penalty parameter values in Q.Clear algorithm for rectal cancer detection on 18F-FDG images using a BGO-based PET/CT scanner: a phantom and clinical study
    Fatemeh Sadeghi
    Peyman Sheikhzadeh
    Saeed Farzanehfar
    Pardis Ghafarian
    Yalda Moafpurian
    Mohammadreza Ay
    EJNMMI Physics, 10
  • [38] American College of Medical Genetics recommendations for the design and performance expectations for clinical genomic copy number microarrays intended for use in the postnatal setting for detection of constitutional abnormalities
    Kearney, Hutton M.
    South, Sarah T.
    Wolff, Daynna J.
    Lamb, Allen
    Hamosh, Ada
    Rao, Kathleen W.
    GENETICS IN MEDICINE, 2011, 13 (07) : 676 - 679