The effects of various penalty parameter values in Q.Clear algorithm for rectal cancer detection on 18F-FDG images using a BGO-based PET/CT scanner: a phantom and clinical study

被引:3
|
作者
Sadeghi, Fatemeh [1 ,2 ]
Sheikhzadeh, Peyman [1 ,3 ]
Farzanehfar, Saeed [3 ]
Ghafarian, Pardis [4 ,5 ]
Moafpurian, Yalda [6 ]
Ay, Mohammadreza [1 ,2 ]
机构
[1] Univ Tehran Med Sci, Dept Med Phys & Biomed Engn, Tehran, Iran
[2] Univ Tehran Med Sci, Adv Med Technol & Equipment Inst AMTEI, Res Ctr Mol & Cellular Imaging RCMCI, Tehran, Iran
[3] Univ Tehran Med Sci, Imam Khomeini Hosp Complex, Dept Nucl Med, Tehran, Iran
[4] Shahid Beheshti Univ Med Sci, Natl Res Inst TB & Lung Dis NRITLD, Chron Resp Dis Res Ctr, Tehran, Iran
[5] Shahid Beheshti Univ Med Sci, Masih Daneshvari Hosp, PET CT & Cyclotron Ctr, Tehran, Iran
[6] Shiraz Univ Med Sci, Dept Nucl Med, Shiraz 7134814336, Iran
关键词
Bayesian method; F-18-FDG; PET-CT; Image reconstruction; RECONSTRUCTION ALGORITHM; OSEM;
D O I
10.1186/s40658-023-00587-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: The Q.Clear algorithm is a fully convergent iterative image reconstruction technique. We hypothesize that different PET/CT scanners with distinct crystal properties will require different optimal settings for the Q.Clear algorithm. Many studies have investigated the improvement of the Q.Clear reconstruction algorithm on PET/CT scanner with LYSO crystals and SiPM detectors. We propose an optimum penalization factor (beta) for the detection of rectal cancer and its metastases using a BGO-based detector PET/CT system which obtained via accurate and comprehensive phantom and clinical studies.Methods: F-18-FDG PET-CT scans were acquired from NEMA phantom with lesion-to-background ratio (LBR) of 2:1, 4:1, 8:1, and 15 patients with rectal cancer. Clinical lesions were classified into two size groups. OSEM and Q.Clear (beta value of 100-500) reconstruction was applied. In Q.Clear, background variability (BV), contrast recovery (CR), signal-to-noise ratio (SNR), SUVmax, and signal-to-background ratio (SBR) were evaluated and compared to OSEM.Results: OSEM had 11.5-18.6% higher BV than Q.Clear using beta value of 500. Conversely, RC from OSEM to Q.Clear using beta value of 500 decreased by 3.3-7.7% for a sphere with a diameter of 10 mm and 2.5-5.1% for a sphere with a diameter of 37 mm. Furthermore, the increment of contrast using a beta value of 500 was 5.2-8.1% in the smallest spheres compared to OSEM. When the beta value was increased from 100 to 500, the SNR increased by 49.1% and 30.8% in the smallest and largest spheres at LBR 2:1, respectively. At LBR of 8:1, the relative difference of SNR between beta value of 100 and 500 was 43.7% and 44.0% in the smallest and largest spheres, respectively. In the clinical study, as beta increased from 100 to 500, the SUVmax decreased by 47.7% in small and 31.1% in large lesions. OSEM demonstrated the least SUVmax, SBR, and contrast. The decrement of SBR and contrast using OSEM were 13.6% and 12.9% in small and 4.2% and 3.4%, respectively, in large lesions.Conclusions: Implementing Q.Clear enhances quantitative accuracies through a fully convergent voxel-based image approach, employing a penalization factor. In the BGO-based scanner, the optimal beta value for small lesions ranges from 200 for LBR 2:1 to 300 for LBR 8:1. For large lesions, the optimal beta value is between 400 for LBR 2:1 and 500 for LBR 8:1. We recommended beta value of 300 for small lesions and beta value of 500 for large lesions in clinical study.
引用
收藏
页数:17
相关论文
共 28 条
  • [1] The effects of various penalty parameter values in Q.Clear algorithm for rectal cancer detection on 18F-FDG images using a BGO-based PET/CT scanner: a phantom and clinical study
    Fatemeh Sadeghi
    Peyman Sheikhzadeh
    Saeed Farzanehfar
    Pardis Ghafarian
    Yalda Moafpurian
    Mohammadreza Ay
    EJNMMI Physics, 10
  • [2] Effects of Q.Clear reconstruction algorithm on predicting distant metastasis of non-small cell lung cancer from 18F-FDG PET/CT images
    Liu, J.
    Wang, R.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 : S762 - S762
  • [3] Implementation of quadratic dose protocol for 18F-FDG whole-body PET imaging using a BGO-based PET/CT scanner, GE Discovery ST
    Musarudin, Marianie
    Selvam, Haniff Shazwan Muhammad Safwan
    Said, Mohamad Aminudin
    IRANIAN JOURNAL OF NUCLEAR MEDICINE, 2019, 27 (02): : 73 - 80
  • [4] Image Registration of 18F-FDG PET/CT Using the MotionFree Algorithm and CT Protocols through Phantom Study and Clinical Evaluation
    Kim, Deok-Hwan
    Yoo, Eun-Hye
    Hong, Ui-Seong
    Kim, Jun-Hyeok
    Ko, Young-Heon
    Moon, Seung-Cheol
    Cheon, Miju
    Yoo, Jang
    HEALTHCARE, 2021, 9 (06)
  • [5] Radiomics in vulvar cancer: first clinical experience using 18F-FDG PET/CT images
    Collarino, A.
    Garganese, G.
    Fragomeni, S. M.
    Arias-Bouda, L. M. Pereira
    Ieria, F. P.
    Barbante, E.
    Boellaard, R.
    Rufini, V.
    de Geus-Oei, L.
    Scambia, G.
    Olmos, R. A. Valdes
    Giordano, A.
    Grootjans, W.
    Van Velden, F. H. P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S218 - S219
  • [6] Radiomics in Vulvar Cancer: First Clinical Experience Using 18F-FDG PET/CT Images
    Collarino, Angela
    Garganese, Giorgia
    Fragomeni, Simona M.
    Arias-Bouda, Lenka M. Pereira
    Ieria, Francesco P.
    Boellaard, Ronald
    Rufini, Vittoria
    de Geus-Oei, Lioe-Fee
    Scambia, Giovanni
    Olmos, Renato A. Valdes
    Giordano, Alessandro
    Grootjans, Willem
    van Velden, Floris H. P.
    JOURNAL OF NUCLEAR MEDICINE, 2019, 60 (02) : 199 - 206
  • [7] Optimization of a Bayesian penalized likelihood algorithm (Q.Clear) for 18F-NaF bone PET/CT images acquired over shorter durations using a custom-designed phantom
    Tokiya Yoshii
    Kenta Miwa
    Masashi Yamaguchi
    Kai Shimada
    Kei Wagatsuma
    Tensho Yamao
    Yuto Kamitaka
    Seiya Hiratsuka
    Rinya Kobayashi
    Hajime Ichikawa
    Noriaki Miyaji
    Tsuyoshi Miyazaki
    Kenji Ishii
    EJNMMI Physics, 7
  • [8] Optimization of a Bayesian penalized likelihood algorithm (Q.Clear) for 18F-NaF bone PET/CT images acquired over shorter durations using a custom-designed phantom
    Yoshii, Tokiya
    Miwa, Kenta
    Yamaguchi, Masashi
    Shimada, Kai
    Wagatsuma, Kei
    Yamao, Tensho
    Kamitaka, Yuto
    Hiratsuka, Seiya
    Kobayashi, Rinya
    Ichikawa, Hajime
    Miyaji, Noriaki
    Miyazaki, Tsuyoshi
    Ishii, Kenji
    EJNMMI PHYSICS, 2020, 7 (01)
  • [9] Diagnostic and prognostic value of time- of-flight 18F-FDG PET/CT in staging of patients with pancreatic ductal adenocarcinoma using TrueX and Q.Clear reconstruction
    Stanzel, S.
    Nazerani-Zemann, T.
    Aigner, R. M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S491 - S491
  • [10] Molecular subtype classification of breast cancer using established radiomic signature models based on 18F-FDG PET/CT images
    Liu, Jianjing
    Bian, Haiman
    Zhang, Yufan
    Gao, Yongchang
    Yin, Guotao
    Wang, Ziyang
    Li, Xiaofeng
    Ma, Wenjuan
    Xu, Wengui
    FRONTIERS IN BIOSCIENCE-LANDMARK, 2021, 26 (09): : 475 - 484