High Spatial-Resolution Skull Base Imaging With Photon-Counting Computed Tomography and Energy-Integrating Computed Tomography: A Comparative Phantom Study

被引:4
|
作者
Rajagopal, Jayasai R. [1 ,2 ]
Schwartz, Fides R. [3 ]
Solomon, Justin B. [1 ]
Enterline, David S. [3 ]
Samei, Ehsan [1 ,4 ]
机构
[1] Duke Univ Med Ctr, Dept Radiol, Med Phys Grad Program, Carl E Ravin Adv Imaging Labs, Durham, NC USA
[2] NIH, Clin Ctr, Radiol & Imaging Sci, Bethesda, MD USA
[3] Duke Univ Med Ctr, Duke Univ Hlth Syst, Dept Radiol, Durham, NC USA
[4] Carl E Ravin Adv Imaging Labs, Hock Plaza,Suite 302,2424 Erwin Rd, Durham, NC 27710 USA
基金
美国国家卫生研究院;
关键词
computed tomography; high-resolution; photon-counting; skull base; CT; SYSTEM; RECONSTRUCTION; HEIGHT; NOISE;
D O I
10.1097/RCT.0000000000001464
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Photon-counting computed tomography (PCCT) offers better high-resolution and noise performance than energy integrating detector (EID) CT. In this work, we compared both technologies for imaging of the temporal bone and skull base. A clinical PCCT system and 3 clinical EID CT scanners were used to image the American College of Radiology image quality phantom using a clinical imaging protocol with matched CTDIvol (CT dose index-volume) of 25 mGy. Images were used to characterize the image quality of each system across a series of high-resolution reconstruction options. Noise was calculated from the noise power spectrum, whereas resolution was quantified with a bone insert by calculating a task transfer function. Images of an anthropomorphic skull phantom and 2 patient cases were examined for visualization of small anatomical structures. Across measured conditions, PCCT had a comparable or smaller average noise magnitude (120 Hounsfield units [HU]) to the EID systems (144-326 HU). Photon-counting CT also had comparable resolution (task transfer function f(25): 1.60 mm(-1)) to the EID systems (1.34-1.77 mm(-1)). Imaging results supported quantitative findings as PCCT more clearly showed the 12-lp/cm bars from the fourth section of the American College of Radiology phantom and better represented the vestibular aqueduct and oval and round windows when compared with the EID scanners. A clinical PCCT system was able to image the temporal bone and skull base with improved spatial resolution and lower noise than clinical EID CT systems at matched dose.
引用
收藏
页码:613 / 620
页数:8
相关论文
共 50 条
  • [41] Multicolor spectral photon-counting computed tomography: in vivo dual contrast imaging with a high count rate scanner
    David P. Cormode
    Salim Si-Mohamed
    Daniel Bar-Ness
    Monica Sigovan
    Pratap C. Naha
    Joelle Balegamire
    Franck Lavenne
    Philippe Coulon
    Ewald Roessl
    Matthias Bartels
    Michal Rokni
    Ira Blevis
    Loic Boussel
    Philippe Douek
    Scientific Reports, 7
  • [42] Photon-Counting Computed Tomography for Vascular Imaging of the Head and Neck First In Vivo Human Results
    Symons, Rolf
    Reich, Daniel S.
    Bagheri, Mohammadhadi
    Cork, Tyler E.
    Krauss, Bernhard
    Ulzheimer, Stefan
    Kappler, Steffen
    Bluemke, David A.
    Pourmorteza, Amir
    INVESTIGATIVE RADIOLOGY, 2018, 53 (03) : 135 - 142
  • [43] Photon-Counting Computed Tomography for Coronary Stent Imaging In Vitro Evaluation of 28 Coronary Stents
    Petritsch, Bernhard
    Petri, Nils
    Weng, Andreas M.
    Petersilka, Martin
    Allmendinger, Thomas
    Bley, Thorsten A.
    Gassenmaier, Tobias
    INVESTIGATIVE RADIOLOGY, 2021, 56 (10) : 653 - 660
  • [44] Multicolor spectral photon-counting computed tomography: in vivo dual contrast imaging with a high count rate scanner
    Cormode, David P.
    Si-Mohamed, Salim
    Bar-Ness, Daniel
    Sigovan, Monica
    Naha, Pratap C.
    Balegamire, Joelle
    Lavenne, Franck
    Coulon, Philippe
    Roessl, Ewald
    Bartels, Matthias
    Rokni, Michal
    Blevis, Ira
    Boussel, Loic
    Douek, Philippe
    SCIENTIFIC REPORTS, 2017, 7
  • [45] Feasibility of photon-counting computed tomography as a novel imaging modality for challenging endodontic diagnostic tasks
    Fontenele, Rocharles Cavalcante
    Picoli, Fernando Fortes
    Pinto, Jader Camilo
    Coudyzer, Walter
    Vasconcelos, Karla de Faria
    Gomes, Amanda Farias
    Binst, Joke
    Jacobs, Reinhilde
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [46] Feasibility of photon-counting computed tomography as a novel imaging modality for challenging endodontic diagnostic tasks
    Rocharles Cavalcante Fontenele
    Fernando Fortes Picoli
    Jader Camilo Pinto
    Walter Coudyzer
    Karla de Faria Vasconcelos
    Amanda Farias Gomes
    Joke Binst
    Reinhilde Jacobs
    Scientific Reports, 13
  • [47] Dedicated Breast Computed Tomography With a Photon-Counting Detector Initial Results of Clinical In Vivo Imaging
    Berger, Nicole
    Marcon, Magda
    Saltybaeva, Natalia
    Kalender, Willi A.
    Alkadhi, Hatem
    Frauenfelder, Thomas
    Boss, Andreas
    INVESTIGATIVE RADIOLOGY, 2019, 54 (07) : 409 - 418
  • [48] Clinical Utility of Multi-Energy Spectral Photon-Counting Computed Tomography in Crystal Arthritis
    Stamp, Lisa K.
    Anderson, Nigel G.
    Becce, Fabio
    Rajeswari, Maya
    Polson, Matthew
    Guyen, Olivier
    Viry, Anais
    Choi, Chloe
    Kirkbride, Tracy E.
    Raja, Aamir Y.
    ARTHRITIS & RHEUMATOLOGY, 2019, 71 (07) : 1158 - 1162
  • [49] ChromAIX: Fast energy resolved photon-counting readout electronics for Future Human Computed Tomography
    Herrmann, Christoph
    Steadman, Roger
    Muelhens, Oliver
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 1996 - 1999
  • [50] Evaluation of Energy Loss and Charge Sharing in Cadmium Telluride Detectors for Photon-Counting Computed Tomography
    Xu, Cheng
    Danielsson, Mats
    Bornefalk, Hans
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2011, 58 (03) : 614 - 625