High Spatial-Resolution Skull Base Imaging With Photon-Counting Computed Tomography and Energy-Integrating Computed Tomography: A Comparative Phantom Study

被引:4
|
作者
Rajagopal, Jayasai R. [1 ,2 ]
Schwartz, Fides R. [3 ]
Solomon, Justin B. [1 ]
Enterline, David S. [3 ]
Samei, Ehsan [1 ,4 ]
机构
[1] Duke Univ Med Ctr, Dept Radiol, Med Phys Grad Program, Carl E Ravin Adv Imaging Labs, Durham, NC USA
[2] NIH, Clin Ctr, Radiol & Imaging Sci, Bethesda, MD USA
[3] Duke Univ Med Ctr, Duke Univ Hlth Syst, Dept Radiol, Durham, NC USA
[4] Carl E Ravin Adv Imaging Labs, Hock Plaza,Suite 302,2424 Erwin Rd, Durham, NC 27710 USA
基金
美国国家卫生研究院;
关键词
computed tomography; high-resolution; photon-counting; skull base; CT; SYSTEM; RECONSTRUCTION; HEIGHT; NOISE;
D O I
10.1097/RCT.0000000000001464
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Photon-counting computed tomography (PCCT) offers better high-resolution and noise performance than energy integrating detector (EID) CT. In this work, we compared both technologies for imaging of the temporal bone and skull base. A clinical PCCT system and 3 clinical EID CT scanners were used to image the American College of Radiology image quality phantom using a clinical imaging protocol with matched CTDIvol (CT dose index-volume) of 25 mGy. Images were used to characterize the image quality of each system across a series of high-resolution reconstruction options. Noise was calculated from the noise power spectrum, whereas resolution was quantified with a bone insert by calculating a task transfer function. Images of an anthropomorphic skull phantom and 2 patient cases were examined for visualization of small anatomical structures. Across measured conditions, PCCT had a comparable or smaller average noise magnitude (120 Hounsfield units [HU]) to the EID systems (144-326 HU). Photon-counting CT also had comparable resolution (task transfer function f(25): 1.60 mm(-1)) to the EID systems (1.34-1.77 mm(-1)). Imaging results supported quantitative findings as PCCT more clearly showed the 12-lp/cm bars from the fourth section of the American College of Radiology phantom and better represented the vestibular aqueduct and oval and round windows when compared with the EID scanners. A clinical PCCT system was able to image the temporal bone and skull base with improved spatial resolution and lower noise than clinical EID CT systems at matched dose.
引用
收藏
页码:613 / 620
页数:8
相关论文
共 50 条
  • [31] Ultra-High Spatial Resolution Images of the Temporal Bone Obtained With a Newly Released Photon-Counting Detector Computed Tomography
    Sakaida, Hiroshi
    Ichikawa, Yasutaka
    Yamazaki, Akio
    Sakuma, Hajime
    Takeuchi, Kazuhiko
    ENT-EAR NOSE & THROAT JOURNAL, 2024,
  • [32] Coronary stent imaging in photon counting computed Tomography: Optimization of reconstruction kernels in a phantom
    Michael, Arwed Elias
    Schoenbeck, Denise
    Becker-Assmann, Jendrik
    Niehoff, Julius Henning
    Flohr, Thomas
    Schmidt, Bernhard
    Panknin, Christoph
    Baer-Beck, Matthias
    Hickethier, Tilman
    Maintz, David
    Bunck, Alexander Christian
    Borggrefe, Jan
    Wiemer, Marcus
    Rudolph, Volker
    Kroeger, Jan Robert
    EUROPEAN JOURNAL OF RADIOLOGY, 2023, 166
  • [33] Quantitative cartilage imaging using spectral photon-counting detector based computed tomography
    Endran, Kishore Raj
    Tao, Shengzhen
    Benike, Amy
    Leng, Shuai
    McCollough, Cynthia
    MEDICAL IMAGING 2019: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2019, 10953
  • [34] Review of Technical Advancements and Clinical Applications of Photon-counting Computed Tomography in Imaging of the Thorax
    Farhadi, Faraz
    Rajagopal, Jayasai R.
    Nikpanah, Moozhan
    Sahbaee, Pooyan
    Malayeri, Ashkan A.
    Pritchard, William F.
    Samei, Ehsan
    Jones, Elizabeth C.
    Chen, Marcus Y.
    JOURNAL OF THORACIC IMAGING, 2021, 36 (02) : 84 - 94
  • [35] Spiral breast computed tomography with a photon-counting detector (SBCT): The future of breast imaging?
    Wetzl, Matthias
    Dietzel, Matthias
    Ohlmeyer, Sabine
    Uder, Michael
    Wenkel, Evelyn
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 157
  • [36] Assessment of Bone Mineral Density From a Computed Tomography Topogram of Photon-Counting Detector Computed Tomography-Effect of Phantom Size and Tube Voltage
    Euler, Andre
    Nowak, Tristan
    Bucher, Brian
    Eberhard, Matthias
    Schmidt, Bernhard
    Flohr, Thomas G.
    Frey, Diana
    Distler, Oliver
    Alkadhi, Hatem
    INVESTIGATIVE RADIOLOGY, 2021, 56 (10) : 614 - 620
  • [37] Spatial resolution of pinhole single photon emission computed tomography imaging
    Dai Qiu-Sheng
    Qi Yu-Jin
    ACTA PHYSICA SINICA, 2010, 59 (02) : 1357 - 1365
  • [38] ChromAIX: A high-rate energy-resolving photon-counting ASIC for Spectral Computed Tomography
    Steadman, Roger
    Herrmann, Christoph
    Muelhens, Oliver
    Maeding, Dale G.
    Colley, James
    Firlit, Ted
    Luhta, Randy
    Chappo, Marc
    Harwood, Brian
    Kosty, Doug
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [39] Prediction of pulmonary function after lung lobectomy by subsegments counting, computed tomography, single photon emission computed tomography and computed tomography: a comparative study
    Yoshimoto, Kentaro
    Nomori, Hiroaki
    Mori, Takeshi
    Kobayashi, Hironori
    Ohba, Yasuomi
    Shibata, Hidekatsu
    Shiraishi, Shinya
    Kobayashi, Toshiaki
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2009, 35 (03) : 408 - 413
  • [40] Photon-counting spectral computed tomography using silicon strip detectors: a feasibility study
    Bornefalk, Hans
    Danielsson, Mats
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (07): : 1999 - 2022