Evaluation of Wrist-Worn Photoplethysmography Trackers with an Electrocardiogram in Patients with Ischemic Heart Disease: A Validation Study

被引:3
|
作者
Ibrahim, Nur Syazwani [1 ]
Rampal, Sanjay [2 ]
Lee, Wan Ling [3 ]
Pek, Eu Way [1 ]
Suhaimi, Anwar [1 ]
机构
[1] Univ Malaya, Fac Med, Dept Rehabil Med, Kuala Lumpur 50603, Malaysia
[2] Univ Malaya, Fac Med, Ctr Epidemiol & Evidence based Practice, Dept Social & Prevent Med, Kuala Lumpur 50603, Malaysia
[3] Univ Malaya, Fac Med, Dept Nursing Sci, Kuala Lumpur 50603, Malaysia
关键词
Fitness tracker; Smartwatch; EKG; Exercise stress test; Validation; VARIABLE ACCURACY; ACTIVITY MONITORS; VALIDITY; WEARABLES; HEALTH;
D O I
10.1007/s13239-023-00693-z
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
PurposePhotoplethysmography measurement of heart rate with wrist-worn trackers has been introduced in healthy individuals. However, additional consideration is necessary for patients with ischemic heart disease, and the available evidence is limited. The study aims to evaluate the validity and reliability of heart rate measures by a wrist-worn photoplethysmography (PPG) tracker compared to an electrocardiogram (ECG) during incremental treadmill exercise among patients with ischemic heart disease.MethodsFifty-one participants performed the standard incremental treadmill exercise in a controlled laboratory setting with 12-lead ECG attached to the patient's body and wearing wrist-worn PPG trackers.ResultsAt each stage, the absolute percentage error of the PPG was within 10% of the standard acceptable range. Further analysis using a linear mixed model, which accounts for individual variations, revealed that PPG yielded the best performance at the baseline low-intensity exercise. As the stages progressed, heart rate validity decreased but was regained during recovery. The reliability was moderate to excellent.ConclusionsLow-cost trackers AMAZFIT Cor and Bip validity and reliability were within acceptable ranges, especially during low-intensity exercise among patients with ischemic heart disease recovering from cardiac procedures. Though using the tracker as part of the diagnosis tool still requires more supporting studies, it can potentially be used as a self-monitoring tool with precautions.
引用
收藏
页码:12 / 21
页数:10
相关论文
共 50 条
  • [41] DIFFERENTIATED EVALUATION OF CHANGES OF REPOLARIZATION PHASE OF THE ELECTROCARDIOGRAM IN PATIENTS WITH ISCHEMIC-HEART-DISEASE
    YANOVSKY, GV
    KOVTUN, LI
    STADNIUK, LA
    VYSOTSKAYA, JM
    GOLUB, NS
    VRACHEBNOE DELO, 1991, (04): : 69 - 70
  • [42] Wrist-worn actigraphy in agitated late-stage dementia patients: A feasibility study on digital inclusion
    Guu, Ta-Wei
    Brem, Anna-Katharine
    Albertyn, Christopher P.
    Kandangwa, Pooja
    Aarsland, Dag
    Ffytche, Dominic
    ALZHEIMERS & DEMENTIA, 2024, 20 (05) : 3211 - 3218
  • [43] Associations Between Heart Rate Variability Measured With a Wrist-Worn Sensor and Older Adults' Physical Function: Observational Study
    Graham, Sarah Anne
    Jest, Dilip, V
    Lee, Ellen E.
    Wu, Tsung-Chin
    Tu, Xin
    Kim, Ho-Cheol
    Depp, Cohn A.
    JMIR MHEALTH AND UHEALTH, 2019, 7 (10):
  • [44] Validation of open-source step-counting algorithms for wrist-worn tri-axial accelerometers in cardiovascular patients
    Femiano, Riccardo
    Werner, Charlotte
    Wilhelm, Matthias
    Eser, Prisca
    GAIT & POSTURE, 2022, 92 : 206 - 211
  • [45] Accuracy of Wrist-Worn Activity Monitors During Common Daily Physical Activities and Types of Structured Exercise: Evaluation Study
    Reddy, Ravi Kondama
    Pooni, Rubin
    Zaharieva, Dessi P.
    Senf, Brian
    El Youssef, Joseph
    Dassau, Eyal
    Doyle, Francis J., III
    Clements, Mark A.
    Rickels, Michael R.
    Patton, Susana R.
    Castle, Jessica R.
    Riddell, Michael C.
    Jacobs, Peter G.
    JMIR MHEALTH AND UHEALTH, 2018, 6 (12):
  • [46] A validation study of the use of smartphones and wrist-worn ActiGraphs to measure physical activity at different levels of intensity and step rates in older people
    Kwan, Rick Yiu Cho
    Liu, Justina Yat Wa
    Lee, Deborah
    Tse, Choi Yeung Andy
    Lee, Paul Hong
    GAIT & POSTURE, 2020, 82 : 306 - 312
  • [47] Electrocardiogram Changes of Donepezil Administration in Elderly Patients with Ischemic Heart Disease
    Wang, Deguo
    Wu, Yong
    Wang, Ancai
    Chen, Yueyun
    Zhang, Ting
    Hu, Nengwei
    CARDIOLOGY RESEARCH AND PRACTICE, 2018, 2018
  • [48] Wrist-worn accelerometer as innovative tool for longitudinal follow-up of idiopathic inflammatory myopathy patients: A pilot study
    Allenbach, Y.
    Foucher, A.
    Champtiaux, N.
    Gilardin, L.
    Hervier, B.
    Benveniste, O.
    Hogrel, J. Y.
    NEUROMUSCULAR DISORDERS, 2015, 25 : S310 - S310
  • [49] Validation and Acceptability of a Cuffless Wrist-Worn Wearable Blood Pressure Monitoring Device Among Users and Health Care Professionals: Mixed Methods Study
    Islam, Sheikh Mohammed Shariful
    Cartledge, Susie
    Karmakar, Chandan
    Rawstorn, Jonathan Charles
    Fraser, Steve F.
    Chow, Clara
    Maddison, Ralph
    JMIR MHEALTH AND UHEALTH, 2019, 7 (10):
  • [50] RESTING AND POSTEXERCISE DIGITAL PLETHYSMOGRAM AND ELECTROCARDIOGRAM IN PATIENTS WITH ISCHEMIC HEART-DISEASE
    YASUE, H
    MORITA, M
    TANAKA, S
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1974, 38 (03): : 215 - 225