Evaluation of Wrist-Worn Photoplethysmography Trackers with an Electrocardiogram in Patients with Ischemic Heart Disease: A Validation Study

被引:3
|
作者
Ibrahim, Nur Syazwani [1 ]
Rampal, Sanjay [2 ]
Lee, Wan Ling [3 ]
Pek, Eu Way [1 ]
Suhaimi, Anwar [1 ]
机构
[1] Univ Malaya, Fac Med, Dept Rehabil Med, Kuala Lumpur 50603, Malaysia
[2] Univ Malaya, Fac Med, Ctr Epidemiol & Evidence based Practice, Dept Social & Prevent Med, Kuala Lumpur 50603, Malaysia
[3] Univ Malaya, Fac Med, Dept Nursing Sci, Kuala Lumpur 50603, Malaysia
关键词
Fitness tracker; Smartwatch; EKG; Exercise stress test; Validation; VARIABLE ACCURACY; ACTIVITY MONITORS; VALIDITY; WEARABLES; HEALTH;
D O I
10.1007/s13239-023-00693-z
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
PurposePhotoplethysmography measurement of heart rate with wrist-worn trackers has been introduced in healthy individuals. However, additional consideration is necessary for patients with ischemic heart disease, and the available evidence is limited. The study aims to evaluate the validity and reliability of heart rate measures by a wrist-worn photoplethysmography (PPG) tracker compared to an electrocardiogram (ECG) during incremental treadmill exercise among patients with ischemic heart disease.MethodsFifty-one participants performed the standard incremental treadmill exercise in a controlled laboratory setting with 12-lead ECG attached to the patient's body and wearing wrist-worn PPG trackers.ResultsAt each stage, the absolute percentage error of the PPG was within 10% of the standard acceptable range. Further analysis using a linear mixed model, which accounts for individual variations, revealed that PPG yielded the best performance at the baseline low-intensity exercise. As the stages progressed, heart rate validity decreased but was regained during recovery. The reliability was moderate to excellent.ConclusionsLow-cost trackers AMAZFIT Cor and Bip validity and reliability were within acceptable ranges, especially during low-intensity exercise among patients with ischemic heart disease recovering from cardiac procedures. Though using the tracker as part of the diagnosis tool still requires more supporting studies, it can potentially be used as a self-monitoring tool with precautions.
引用
收藏
页码:12 / 21
页数:10
相关论文
共 50 条
  • [31] Feasibility characteristics of wrist-worn fitness trackers in health status monitoring for post-COVID patients in remote and rural areas
    Wiebe, Madeleine
    Mackay, Marnie
    Krishnan, Ragur
    Tian, Julie
    Larsson, Jakob
    Modanloo, Setayesh
    Mcintosh, Christiane Job
    Sztym, Melissa
    Elton-Smith, Gail
    Rose, Alyssa
    Ho, Chester
    Greenshaw, Andrew
    Cao, Bo
    Chan, Andrew
    Hayward, Jake
    PLOS DIGITAL HEALTH, 2024, 3 (08):
  • [32] Wrist-worn optical and chest strap heart rate comparison in a heterogeneous sample of healthy individuals and in coronary artery disease patients
    Francesco Sartor
    Jos Gelissen
    Ralph van Dinther
    David Roovers
    Gabriele B. Papini
    Giuseppe Coppola
    BMC Sports Science, Medicine and Rehabilitation, 10
  • [33] Wrist-worn optical and chest strap heart rate comparison in a heterogeneous sample of healthy individuals and in coronary artery disease patients
    Sartor, Francesco
    Gelissen, Jos
    Van Dinther, Ralph
    Roovers, David
    Papini, Gabriele B.
    Coppola, Giuseppe
    BMC SPORTS SCIENCE MEDICINE AND REHABILITATION, 2018, 10
  • [34] Design Rationale and Performance Evaluation of the Wavelet Health Wristband: Benchtop Validation of a Wrist-Worn Physiological Signal Recorder
    Dur, Onur
    Rhoades, Colleen
    Ng, Man Suen
    Elsayed, Ragwa
    van Mourik, Reinier
    Majmudar, Maulik D.
    JMIR MHEALTH AND UHEALTH, 2018, 6 (10):
  • [35] Comparison of Time-Domain Short-Term Heart Interval Variability Analysis Using a Wrist-Worn Heart Rate Monitor and the Conventional Electrocardiogram
    Grossi Porto, Luiz Guilherme
    Junqueira, Luiz F., Jr.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2009, 32 (01): : 43 - 51
  • [36] Accuracy of a Wrist-Worn Wearable Device for Monitoring Heart Rates in Hospital Inpatients: A Prospective Observational Study
    Kroll, Ryan R.
    Boyd, Gordon
    Maslove, David M.
    JOURNAL OF MEDICAL INTERNET RESEARCH, 2016, 18 (09)
  • [37] Influence of Skin Tone on Accuracy of Wrist-Worn Photoplethysmographic Heart Rate During Exercise: A Pilot Study
    Mulholland, Anne M.
    MacDonald, Hayley V.
    Reuben, Garrett
    Zelhart, Preston
    Aguiar, Elroy J.
    Wingo, Jonathan E.
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2024, 56 (10) : 965 - 965
  • [38] Wrist-worn devices for the measurement of heart rate and energy expenditure: A validation study for the Apple Watch 6, Polar Vantage V and Fitbit Sense
    Hajj-Boutros, Guy
    Landry-Duval, Marie-Anne
    Comtois, Alain Steve
    Gouspillou, Gilles
    Karelis, Antony D.
    EUROPEAN JOURNAL OF SPORT SCIENCE, 2023, 23 (02) : 165 - 177
  • [39] Wrist-Worn Wearables for Monitoring Heart Rate and Energy Expenditure While Sitting or Performing Light-to-Vigorous Physical Activity: Validation Study
    Dueking, Peter
    Giessing, Laura
    Frenkel, Marie Ottilie
    Koehler, Karsten
    Holmberg, Hans-Christer
    Sperlich, Billy
    JMIR MHEALTH AND UHEALTH, 2020, 8 (05):
  • [40] Predicting Wearing-Off of Parkinson's Disease Patients Using a Wrist-Worn Fitness Tracker and a Smartphone: A Case Study
    Victorino, John Noel
    Shibata, Yuko
    Inoue, Sozo
    Shibata, Tomohiro
    APPLIED SCIENCES-BASEL, 2021, 11 (16):