Flexible Antenna Sensor in Thumb Spica Splint for Noninvasive Monitoring of Fluctuating Blood Glucose Levels

被引:4
|
作者
Sindhuja, S. [1 ]
Kanniga, E. [2 ,3 ]
机构
[1] Bharath Inst Higher Educ & Res, Dept Elect & Commun Engn, Chennai 600126, India
[2] Bharath Inst Higher Educ & Res, Dept Elect & Commun Engn CMERME, Chennai 600126, India
[3] Bharath Inst Higher Educ & Res, CEDSE EIE, Chennai 600126, India
关键词
Glucose; Sensors; Antenna measurements; Blood; Antennas; Thumb; Dielectrics; Blood glucose; noninvasive glucose monitoring; passive antenna sensors; regression modeling; RESONATOR;
D O I
10.1109/JSEN.2022.3223948
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Antenna is used as a sensor in wearable technology because of its small size. Reduced flexible antenna size avoids mounting problems and crumbling effects on the human skin region during signal acquisition. Moreover, continuous diabetes monitoring needs an efficient antenna sensor design. In this article, we develop a continuous glucose monitoring device using a flexible antenna sensor planted inside the thumb spica splint glove. The flexible antenna sensor comprises polyimide substrate with ?r = 3.5, tand = 0.0027, and a thickness of 0.1 mm. The proposed flexible antenna sensor senses dielectric radiations from glucose in the blood and improves the accuracy of glucose-level prediction. Traditional antenna sensor methods use skin layers and muscles as sources of permittivity, resulting in errors in diabetic value measurement. The acquired antenna sensor signal from the designed thumb spica splint glove is processed using the tunable Q-factor wavelet transform (TQWT) algorithm. It differentiates the dielectric properties of glucose in the blood, skin, and muscle through subband energy levels. The subband energy level of glucose from the proposed antenna sensor and the quadratic regression algorithm is used to predict the human glucose level. The predicted glucose levels using the proposed flexible antenna are validated through Accu-Chek Active Glucometer. From experimental results, the proposed method-based glucose prediction-level accuracy achieved about 96.8% compared to traditional methods.
引用
收藏
页码:544 / 551
页数:8
相关论文
共 50 条
  • [41] Experimental Based Blood Glucose Monitoring with a Noninvasive Cylindrical Biosensor
    Rahayu Y.
    Nugraha W.N.
    Praludi T.
    Alaydrus M.
    Anhar
    Masdar H.
    Progress In Electromagnetics Research M, 2023, 115 : 71 - 81
  • [42] THE STRUCTURE OPTIMIZATION ABOUT NONINVASIVE BLOOD GLUCOSE MONITORING DEVICES
    Chen, N.
    Chen, Z. B.
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2016, 118 : 98 - 98
  • [43] Noninvasive blood glucose monitoring by novel optical fiber probe
    Maruo, K
    Chin, J
    Tamura, M
    OPTICAL DIAGNOSTICS AND SENSING OF BIOLOGICAL FLUIDS AND GLUCOSE AND CHOLESTEROL MONITORING II, 2002, 4624 : 20 - 27
  • [44] Experimental Based Blood Glucose Monitoring with a Noninvasive Cylindrical Biosensor
    Rahayu, Yusnita
    Nugraha, Wahid N.
    Praludi, Teguh
    Alaydrus, Mudrik
    Anhar
    Masdar, Huriatul
    PROGRESS IN ELECTROMAGNETICS RESEARCH M, 2023, 115 : 71 - 81
  • [45] Investigation of Resonant Frequency and Impedance for Noninvasive Blood Glucose Monitoring
    Li, Jingzhen
    Yang, Dardei
    Nie, Zedong
    Liu, Yuhang
    Wang, Lei
    2017 IEEE 7TH ANNUAL INTERNATIONAL CONFERENCE ON CYBER TECHNOLOGY IN AUTOMATION, CONTROL, AND INTELLIGENT SYSTEMS (CYBER), 2017, : 1649 - 1652
  • [46] Sweet Future: Fluctuating Blood Glucose Levels Affect Future Discounting
    Wang, X. T.
    Dvorak, Robert D.
    PSYCHOLOGICAL SCIENCE, 2010, 21 (02) : 183 - 188
  • [47] Miniature Implantable Antenna Design for Blood Glucose Monitoring
    Ahmed, Ayesha
    Ur-Rehman, Masood
    Abbasi, Qammer Hussain
    2018 INTERNATIONAL APPLIED COMPUTATIONAL ELECTROMAGNETICS SOCIETY SYMPOSIUM (ACES), 2018,
  • [48] Simulation of a device concept for noninvasive sensing of blood glucose levels
    Handapangoda, Chintha C.
    Premaratne, Malin
    Paganin, David M.
    2007 THIRD INTERNATIONAL CONFERENCE ON INFORMATION AND AUTOMATION FOR SUSTAINABILITY, 2007, : 31 - +
  • [49] Hybrid integrated optical sensor for noninvasive blood flow monitoring
    Higurashi, E
    Sawada, R
    Ito, T
    2002 IEEE/LEOS INTERNATIONAL CONFERENCE ON OPTICAL MEMS, CONFERENCE DIGEST, 2002, : 33 - 34
  • [50] Optical sensor technology for a noninvasive continuous monitoring of blood components
    Kraitl, Jens
    Timm, Ulrich
    Lewis, Elfed
    Ewald, Hartmut
    OPTICAL DIAGNOSTICS AND SENSING X: TOWARD POINT-OF-CARE DIAGNOSTICS, 2010, 7572