Flexible Antenna Sensor in Thumb Spica Splint for Noninvasive Monitoring of Fluctuating Blood Glucose Levels

被引:4
|
作者
Sindhuja, S. [1 ]
Kanniga, E. [2 ,3 ]
机构
[1] Bharath Inst Higher Educ & Res, Dept Elect & Commun Engn, Chennai 600126, India
[2] Bharath Inst Higher Educ & Res, Dept Elect & Commun Engn CMERME, Chennai 600126, India
[3] Bharath Inst Higher Educ & Res, CEDSE EIE, Chennai 600126, India
关键词
Glucose; Sensors; Antenna measurements; Blood; Antennas; Thumb; Dielectrics; Blood glucose; noninvasive glucose monitoring; passive antenna sensors; regression modeling; RESONATOR;
D O I
10.1109/JSEN.2022.3223948
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Antenna is used as a sensor in wearable technology because of its small size. Reduced flexible antenna size avoids mounting problems and crumbling effects on the human skin region during signal acquisition. Moreover, continuous diabetes monitoring needs an efficient antenna sensor design. In this article, we develop a continuous glucose monitoring device using a flexible antenna sensor planted inside the thumb spica splint glove. The flexible antenna sensor comprises polyimide substrate with ?r = 3.5, tand = 0.0027, and a thickness of 0.1 mm. The proposed flexible antenna sensor senses dielectric radiations from glucose in the blood and improves the accuracy of glucose-level prediction. Traditional antenna sensor methods use skin layers and muscles as sources of permittivity, resulting in errors in diabetic value measurement. The acquired antenna sensor signal from the designed thumb spica splint glove is processed using the tunable Q-factor wavelet transform (TQWT) algorithm. It differentiates the dielectric properties of glucose in the blood, skin, and muscle through subband energy levels. The subband energy level of glucose from the proposed antenna sensor and the quadratic regression algorithm is used to predict the human glucose level. The predicted glucose levels using the proposed flexible antenna are validated through Accu-Chek Active Glucometer. From experimental results, the proposed method-based glucose prediction-level accuracy achieved about 96.8% compared to traditional methods.
引用
收藏
页码:544 / 551
页数:8
相关论文
共 50 条
  • [31] Increased intestinal permeability as a cause of fluctuating blood glucose levels
    Damci, T
    Nuhoglu, I
    Devranoglu, G
    Osar, Z
    Demir, M
    Ilkova, H
    DIABETOLOGIA, 2001, 44 : A293 - A293
  • [32] Modern noninvasive methods for monitoring glucose levels in patients: a review
    Dziergowska, Katarzyna
    Labowska, Magdalena Beata
    Gasior-Glogowska, Marlena
    Kmiecik, Barbara
    Detyna, Jerzy
    BIO-ALGORITHMS AND MED-SYSTEMS, 2019, 15 (04)
  • [33] A flexible optoacoustic blood 'stethoscope' for noninvasive multiparametric cardiovascular monitoring
    Jin, Haoran
    Zheng, Zesheng
    Cui, Zequn
    Jiang, Ying
    Chen, Geng
    Li, Wenlong
    Wang, Zhimin
    Wang, Jilei
    Yang, Chuanshi
    Song, Weitao
    Chen, Xiaodong
    Zheng, Yuanjin
    NATURE COMMUNICATIONS, 2023, 14 (01)
  • [34] A flexible optoacoustic blood ‘stethoscope’ for noninvasive multiparametric cardiovascular monitoring
    Haoran Jin
    Zesheng Zheng
    Zequn Cui
    Ying Jiang
    Geng Chen
    Wenlong Li
    Zhimin Wang
    Jilei Wang
    Chuanshi Yang
    Weitao Song
    Xiaodong Chen
    Yuanjin Zheng
    Nature Communications, 14
  • [35] Noninvasive Blood Glucose Detection Using Near Infrared Sensor
    Hotmartua, Rolamjaya
    Pangestu, Pujianto Wira
    Zakaria, Hasballah
    Irawan, Yoke Saadia
    5TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING AND INFORMATICS 2015, 2015, : 687 - 692
  • [36] Initial validation of optical coherence tomography based sensor for monitoring of blood glucose levels
    Schurman, M
    Shakespeare, W
    Wilkins, RG
    Merkle, L
    Herr, D
    Wilson, R
    CRITICAL CARE MEDICINE, 2005, 33 (12) : A73 - A73
  • [37] Specificity of noninvasive blood glucose monitoring with optical coherence tomography
    Larin, KV
    Ashitkov, TV
    Motamedi, M
    Esenaliev, RO
    OPTICAL DIAGNOSTICS AND SENSING IN BIOMEDICINE III, 2003, 4965 : 25 - 31
  • [38] Phantoms for Development of Microwave Sensors for Noninvasive Blood Glucose Monitoring
    Vrba, Jan
    Karch, Jakub
    Vrba, David
    INTERNATIONAL JOURNAL OF ANTENNAS AND PROPAGATION, 2015, 2015
  • [39] Body metabolism provides a foundation for noninvasive blood glucose monitoring
    Ko, JB
    Cho, OK
    Kim, YO
    Yasuda, K
    DIABETES CARE, 2004, 27 (05) : 1211 - 1212
  • [40] Cutaneous Blood Perfusion as a Perturbing Factor for Noninvasive Glucose Monitoring
    Caduff, Andreas
    Talary, Mark S.
    Zakharov, Pavel