Flexible Antenna Sensor in Thumb Spica Splint for Noninvasive Monitoring of Fluctuating Blood Glucose Levels

被引:4
|
作者
Sindhuja, S. [1 ]
Kanniga, E. [2 ,3 ]
机构
[1] Bharath Inst Higher Educ & Res, Dept Elect & Commun Engn, Chennai 600126, India
[2] Bharath Inst Higher Educ & Res, Dept Elect & Commun Engn CMERME, Chennai 600126, India
[3] Bharath Inst Higher Educ & Res, CEDSE EIE, Chennai 600126, India
关键词
Glucose; Sensors; Antenna measurements; Blood; Antennas; Thumb; Dielectrics; Blood glucose; noninvasive glucose monitoring; passive antenna sensors; regression modeling; RESONATOR;
D O I
10.1109/JSEN.2022.3223948
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Antenna is used as a sensor in wearable technology because of its small size. Reduced flexible antenna size avoids mounting problems and crumbling effects on the human skin region during signal acquisition. Moreover, continuous diabetes monitoring needs an efficient antenna sensor design. In this article, we develop a continuous glucose monitoring device using a flexible antenna sensor planted inside the thumb spica splint glove. The flexible antenna sensor comprises polyimide substrate with ?r = 3.5, tand = 0.0027, and a thickness of 0.1 mm. The proposed flexible antenna sensor senses dielectric radiations from glucose in the blood and improves the accuracy of glucose-level prediction. Traditional antenna sensor methods use skin layers and muscles as sources of permittivity, resulting in errors in diabetic value measurement. The acquired antenna sensor signal from the designed thumb spica splint glove is processed using the tunable Q-factor wavelet transform (TQWT) algorithm. It differentiates the dielectric properties of glucose in the blood, skin, and muscle through subband energy levels. The subband energy level of glucose from the proposed antenna sensor and the quadratic regression algorithm is used to predict the human glucose level. The predicted glucose levels using the proposed flexible antenna are validated through Accu-Chek Active Glucometer. From experimental results, the proposed method-based glucose prediction-level accuracy achieved about 96.8% compared to traditional methods.
引用
收藏
页码:544 / 551
页数:8
相关论文
共 50 条
  • [1] A Noninvasive Method of Monitoring Blood Glucose Levels by Using Triple-Band Monopole Antenna
    Sharaf, Faten
    Elsheakh, Dalia N.
    Eldamak, Angie R.
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2025, 67 (01)
  • [2] Flexible Microwave Plasmonic Sensor for Noninvasive Measurement of Blood Glucose
    Zhou, Yong Jin
    Xu, Jian
    Dai, Li Hui
    2021 13TH GLOBAL SYMPOSIUM ON MILLIMETER-WAVES & TERAHERTZ (GSMM), 2021,
  • [3] Monitoring of glucose levels in mouse blood with noninvasive optical methods
    Ullah, H.
    Ahmed, E.
    Ikram, M.
    LASER PHYSICS, 2014, 24 (02)
  • [4] Noninvasive blood glucose monitoring
    Klonoff, DC
    DIABETES CARE, 1997, 20 (03) : 433 - 437
  • [5] Noninvasive Blood Pressure Monitoring via a Flexible and Wearable Piezoresistive Sensor
    Bijender
    Kumar, Shubham
    Soni, Amit
    Yadav, Rimjhim
    Singh, Surinder P.
    Kumar, Ashok
    ACS OMEGA, 2024, 9 (06): : 6355 - 6365
  • [6] Development of noninvasive procedure for monitoring blood glucose levels using saliva
    Yamaguchi, M
    Mitsumori, M
    Kano, Y
    PROCEEDINGS OF THE 20TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 20, PTS 1-6: BIOMEDICAL ENGINEERING TOWARDS THE YEAR 2000 AND BEYOND, 1998, 20 : 1763 - 1766
  • [7] Design of a noninvasive blood glucose Sensor
    Nguyen, D.
    Wang-Roveda, Janet Meiling
    NANOTECHNOLOGY 2012, VOL 3: BIO SENSORS, INSTRUMENTS, MEDICAL, ENVIRONMENT AND ENERGY, 2012, : 56 - 59
  • [8] Noninvasive optical glucose monitoring at physiological levels using a functionalized plasmonic sensor
    Mesch, Martin
    Zhang, Chunjie
    Braun, Paul V.
    Rapp, Philipp
    Tarin, Cristina
    Giessen, Harald
    2013 CONFERENCE ON LASERS AND ELECTRO-OPTICS EUROPE AND INTERNATIONAL QUANTUM ELECTRONICS CONFERENCE (CLEO EUROPE/IQEC), 2013,
  • [9] Design and In Vitro Interference Test of Microwave Noninvasive Blood Glucose Monitoring Sensor
    Choi, Heungjae
    Naylon, Jack
    Luzio, Steve
    Beutler, Jan
    Birchall, James
    Martin, Chris
    Porch, Adrian
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2015, 63 (10) : 3016 - 3025
  • [10] Microwave Noninvasive Blood Glucose Monitoring Sensor: Penetration Depth and Sensitivity Analysis
    Choi, Heungjae
    Luzio, Steve
    Beutler, Jan
    Porch, Adrian
    PROCEEDINGS OF THE 2018 IEEE/MTT-S INTERNATIONAL MICROWAVE BIOMEDICAL CONFERENCE (IMBIOC), 2018, : 52 - 54