Comparison of 3 different bone-borne type expansion appliances used in surgically-assisted rapid palatal expansion: A finite element analysis

被引:2
|
作者
Koc, Osman [1 ]
Pamukcu, Hande [2 ]
Kocabalkan, Azize Atakan [2 ]
机构
[1] Yildiz Tech Univ, Fac Mech Engn, Istanbul, Turkiye
[2] Baskent Univ, Sch Dent, Dept Orthodont, Ankara, Turkiye
关键词
MAXILLARY EXPANSION; MINI-IMPLANTS; TOOTH-BORNE; EXPANDERS; STABILITY; SKELETAL; ANCHORAGE;
D O I
10.1016/j.ajodo.2022.12.001
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: This study aimed to compare the effects of 3 different bone-borne type expansion appliances used in the surgically-assisted rapid palatal expansion (SARPE) by finite element analysis. Methods: Three different miniscrew-supported palatal expansion appliances were modeled. Median and lateral osteotomies were performed without pterygomaxillary suture separation. Model I consisted of a palatal expander with 2 miniscrews placed 4 mm far from the midpalatal suture. In model II, 2 miniscrews were located at the alveolar ridge between the first molar and the second premolar. In model III, 4 miniscrews were placed as a combination of the first and second models. Stress distributions and amount of displacements were evaluated with Ansys software (version 19.2; Ansys, Canonsburg, Pa) for 5-mm expansion in a symmetrical finite element analysis model to reflect the clinical situation. Results: SARPE simulation using miniscrew-assisted maxillary expanders for all models showed a rotation and tipping of the maxilla. The largest displacement was found for the anterior part of the palate in model II and the posterior part in model III. Although a wedge-shaped expansion pattern was observed in all models, this form was more prominent in model II. The highest stress value (0.91 MPa) was measured in model I, and the lowest value (0.004 MPa) was measured in model II for the anterior nasal spine region. The highest stress value (0.51 MPa) was measured in model III, and the lowest value (0.12 MPa) was measured in model II for the posterior nasal spine region. The lowest stress values were measured in model II for all the craniofacial and maxillofacial structures. Conclusions: Among the models, the lowest stress distribution conditions for craniofacial and maxil-lofacial structures were found in model II. The largest displacement was found at the incisors and anterior part of the maxilla for model II. The greatest displacement was found at the posterior region for model III.
引用
收藏
页码:e23 / e33
页数:11
相关论文
共 50 条
  • [41] Three-dimensional evaluation of soft tissue changes in the orofacial region after tooth-borne and bone-borne surgically assisted rapid maxillary expansion
    Nada, Rania M.
    van Loon, Bram
    Maal, Thomas J. J.
    Berge, Stefaan J.
    Mostafa, Yehya A.
    Kuijpers-Jagtman, Anne Marie
    Schols, Jan G. J. H.
    CLINICAL ORAL INVESTIGATIONS, 2013, 17 (09) : 2017 - 2024
  • [42] Direct bone placement of the hyrax fixation screw for surgically assisted rapid palatal expansion (SARPE)
    Harzer, Winfried
    Schneider, Matthias
    Gedrange, Tomasz
    Tausche, Eve
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2006, 64 (08) : 1313 - 1317
  • [43] Biomechanical Analysis of Orthodontic Miniscrew-Assisted Rapid Palatal Expansion on Dental and Bone Tissues: A Finite-Element Study
    Mamboleo, Egon
    Ouldyerou, Abdelhak
    Alsharif, Khaled
    Ngan, Peter
    Merdji, Ali
    Roy, Sandipan
    Mukdadi, Osama M.
    Journal of Engineering and Science in Medical Diagnostics and Therapy, 2024, 7 (04)
  • [44] Is There a Difference in Mid-Palatal Suture Density after Rapid Maxillary Expansion, Surgically Assisted Rapid Maxillary Expansion, and Miniscrew-Assisted Rapid Palatal Expansion? A Systematic Review and Meta-Analysis
    Mello Figueiredo, Laura
    Mascarenhas Calixto Barros, Daniella
    Costa Veloso, Natalia
    Oliveira Lisboa, Cinthia
    Mourao, Carlos Fernando
    Cury-Saramago, Adriana de Alcantara
    Trindade Mattos, Claudia
    de Albuquerque Calasans-Maia, Jose
    APPLIED SCIENCES-BASEL, 2023, 13 (19):
  • [45] The Hyrax appliance with tooth anchorage variations in surgically assisted rapid maxillary expansion: a finite element analysis
    Silveira Tomazi, Flavio Henrique
    Conci, Ricardo Augusto
    Heitz, Claiton
    Noritomi, Pedro Yoshito
    de Menezes, Luciane Macedo
    Santayana de Lima, Eduardo Martinelli
    Teixeira, Eduardo Rolim
    ORAL AND MAXILLOFACIAL SURGERY-HEIDELBERG, 2023, 27 (04): : 647 - 654
  • [46] The Hyrax appliance with tooth anchorage variations in surgically assisted rapid maxillary expansion: a finite element analysis
    Flavio Henrique Silveira Tomazi
    Ricardo Augusto Conci
    Claiton Heitz
    Pedro Yoshito Noritomi
    Luciane Macedo de Menezes
    Eduardo Martinelli Santayana de Lima
    Eduardo Rolim Teixeira
    Oral and Maxillofacial Surgery, 2023, 27 : 647 - 654
  • [47] Comparison of root resorption after bone-borne and tooth-borne rapid maxillary expansion evaluated with the use of microtomography
    Yildirim, Mucahid
    Akin, Mehmet
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2019, 155 (02) : 182 - 190
  • [48] Effects of miniscrew location on biomechanical performances of bone-borne rapid palatal expander to midpalatal suture: A finite element study
    Sermboonsang, Chayapa
    Benjakul, Sutiwa
    Chantarapanich, Nattapon
    Inglam, Samroeng
    Insee, Kanlaya
    MEDICAL ENGINEERING & PHYSICS, 2022, 107
  • [49] Bone density of the midpalatal suture 7 months after surgically assisted rapid palatal expansion in adults
    Petrick, Silvia
    Hothan, Thorsten
    Hietschold, Volker
    Schneider, Matthias
    Harzer, Winfried
    Tausche, Eve
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2011, 139 (04) : S109 - S116
  • [50] Evaluation and Comparison of Root Resorption Resulting from Traditional and Bone-borne Rapid Maxillary Expansion Appliances Using Cone-beam Computed Tomography
    Akin, Mehmet
    Ozturk, Onur
    MEANDROS MEDICAL AND DENTAL JOURNAL, 2021, 22 (01): : 77 - 84