Comparison of 3 different bone-borne type expansion appliances used in surgically-assisted rapid palatal expansion: A finite element analysis

被引:2
|
作者
Koc, Osman [1 ]
Pamukcu, Hande [2 ]
Kocabalkan, Azize Atakan [2 ]
机构
[1] Yildiz Tech Univ, Fac Mech Engn, Istanbul, Turkiye
[2] Baskent Univ, Sch Dent, Dept Orthodont, Ankara, Turkiye
关键词
MAXILLARY EXPANSION; MINI-IMPLANTS; TOOTH-BORNE; EXPANDERS; STABILITY; SKELETAL; ANCHORAGE;
D O I
10.1016/j.ajodo.2022.12.001
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: This study aimed to compare the effects of 3 different bone-borne type expansion appliances used in the surgically-assisted rapid palatal expansion (SARPE) by finite element analysis. Methods: Three different miniscrew-supported palatal expansion appliances were modeled. Median and lateral osteotomies were performed without pterygomaxillary suture separation. Model I consisted of a palatal expander with 2 miniscrews placed 4 mm far from the midpalatal suture. In model II, 2 miniscrews were located at the alveolar ridge between the first molar and the second premolar. In model III, 4 miniscrews were placed as a combination of the first and second models. Stress distributions and amount of displacements were evaluated with Ansys software (version 19.2; Ansys, Canonsburg, Pa) for 5-mm expansion in a symmetrical finite element analysis model to reflect the clinical situation. Results: SARPE simulation using miniscrew-assisted maxillary expanders for all models showed a rotation and tipping of the maxilla. The largest displacement was found for the anterior part of the palate in model II and the posterior part in model III. Although a wedge-shaped expansion pattern was observed in all models, this form was more prominent in model II. The highest stress value (0.91 MPa) was measured in model I, and the lowest value (0.004 MPa) was measured in model II for the anterior nasal spine region. The highest stress value (0.51 MPa) was measured in model III, and the lowest value (0.12 MPa) was measured in model II for the posterior nasal spine region. The lowest stress values were measured in model II for all the craniofacial and maxillofacial structures. Conclusions: Among the models, the lowest stress distribution conditions for craniofacial and maxil-lofacial structures were found in model II. The largest displacement was found at the incisors and anterior part of the maxilla for model II. The greatest displacement was found at the posterior region for model III.
引用
收藏
页码:e23 / e33
页数:11
相关论文
共 50 条
  • [21] Stability and surgical complications of tooth-borne and bone-borne appliances in surgical assisted rapid maxillary expansion: a systematic review
    Munoz-Pereira, M. E.
    Haas-Junior, O. L.
    Meirelles, L. Da Silva
    Machado-Fernandez, A.
    Guijarro-Martinez, R.
    Hernandez-Alfaro, F.
    de Oliveira, R. B.
    Pagnoncelli, R. M.
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2021, 59 (02): : E29 - E47
  • [22] Three-dimensional evaluation of surgically assisted implant bone-borne rapid maxillary expansion:: A pilot study
    Tausche, Eve
    Hansen, Lars
    Hietschold, Volker
    Lagravere, Manuel O.
    Harzer, Winfried
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2007, 131 (04) : S92 - S99
  • [23] Resident Commentary: Is There a Significant Difference in Relapse and Complication Rate of Surgically Assisted Rapid Palatal Expansion Using Tooth-Borne, Bone-Borne, and Orthodontic Mini-Implant-Borne Appliances (Ploder et al, 2020)?
    Akbari, Maryam
    Prabhu, Rohan
    Khanna, Sagar
    Turner, Michael D.
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2021, 79 (01) : E1 - E3
  • [24] A systematic review of the effects of bone-borne surgical assisted rapid maxillary expansion
    Verstraaten, Jeroen
    Kuijpers-Jagtman, Anne M.
    Mommaerts, Maurice Y.
    Berge, Stefaan J.
    Nada, Rania M.
    Schols, Jan G. J. H.
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2010, 38 (03) : 166 - 174
  • [25] Displacement and stress distribution by different bone-borne palatal expanders with facemask: A 3-dimensional finite element analysis
    Park, Jae Hyun
    Bayome, Mohamed
    Zahrowski, James J.
    Kook, Yoon-Ah
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2017, 151 (01) : 105 - 117
  • [26] Esthetic smile analysis after surgically assisted rapid palatal expansion
    Carvalho, A.
    Goldenberg, F.
    Kanashiro, L.
    Goldenberg, D.
    CRANIOFACIAL SURGERY: PROCEEDINGS OF THE TWELFTH INTERNATIONAL CONGRESS OF THE INTERNATIONAL SOCIETY OF CRANIOFACIAL SURGERY, 2007, : 157 - 160
  • [27] Effect of microimplant assisted rapid palatal expansion on bone-anchored maxillary protraction: A finite element analysis
    Suresh, Sugitha
    Sundareswaran, Shobha
    Sathyanadhan, Sreehari
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2021, 160 (04) : 523 - 532
  • [28] Comparison of the effects of sedation and general anesthesia in surgically assisted rapid palatal expansion
    Kim, Yong H.
    Jeon, Sang Y.
    Park, Jae H.
    Choe, Ji H.
    SAUDI MEDICAL JOURNAL, 2011, 32 (12) : 1316 - 1316
  • [29] Comparison of the effects of sedation and general anesthesia in surgically assisted rapid palatal expansion
    Satilmis, Tulin
    Ugurlu, Faysal
    Garip, Hasan
    Sener, Bedrettin C.
    Goker, Kamil
    SAUDI MEDICAL JOURNAL, 2011, 32 (06) : 593 - 597
  • [30] CT Analysis of Nasal Volume Changes after Surgically-assisted Rapid Maxillary Expansion
    Tausche, Eve
    Deeb, Wayel
    Hansen, Lars
    Hietschold, Volker
    Harzer, Winfried
    Schneider, Matthias