Rapid prototyping Lab-on-Chip devices for the future: A numerical optimisation of bulk optical parameters in microfluidic systems

被引:0
|
作者
Lu, Sarah E. [1 ,5 ]
Morris, Andrew [2 ]
Clinton-Bailey, Geraldine [2 ]
Namiq, Medya [3 ]
Gow, Paul C. [3 ]
Birchill, Antony [2 ,4 ]
Steigenberger, Sebastian [2 ]
Wyatt, James [2 ]
Forrester, Reuben [2 ]
Mowlem, Matthew C. [2 ]
Warwick, Phillip E. [1 ]
机构
[1] Univ Southampton, Natl Oceanog Ctr, European Way, Southampton SO14 3ZH, England
[2] Natl Oceanog Ctr, Ocean Technol & Engn Grp, Southampton SO14 3ZH, England
[3] Univ Southampton, Optoelect Res Ctr, Southampton SO17 1BJ, England
[4] Univ Portsmouth, Sch Environm Geog & Geosci, Portsmouth PO1 2UP, England
[5] Univ Southampton, Fac Environm & Life Sci, Sch Ocean & Earth Sci, Natl Oceanog Ctr, European Way, Southampton S014 3ZH, England
关键词
Lab on Chip; Ray tracing; Optical modelling; Global warming; Radionuclides; Nuclear industry; MINIATURIZED QUALITY-CONTROL; HYDROGEN-PEROXIDE; BETA PARTICLES; PET; RADIONUCLIDES; MANGANESE; WATER; CELL; RADIOCHEMISTRY; SEPARATION;
D O I
10.1016/j.sna.2023.114496
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Nuclear reactor process control is typically monitored for pure & beta;-emitting radionuclides via manual sampling followed by laboratory analysis, leading to delays in data availability and response times. The development of an in situ microfluidic Lab on Chip (LoC) system with integrated detection capable of measuring pure & beta;-emitting radionuclides presents a promising solution, enabling a reduction in occupational exposure and cost of monitoring whilst providing improved temporal resolution through near real-time data acquisition. However, testing prototypes with radioactive sources is time-consuming, requires specialist facilities/equipment, generates contaminated waste, and cannot rapidly evaluate a wide range of designs or configurations. Despite this, modelling multiple design parameters and testing their impact on detection with non-radioactive substitutes has yet to be adopted as best practice. The measurement of pure & beta; emitters in aqueous media relies on the efficient transport of photons generated by the Cherenkov effect or liquid scintillators to the detector. Here we explore the role of numerical modelling to assess the impact of optical cell geometry and design on photon transmission and detection through the microfluidic system, facilitating improved designs to realise better efficiency of integrated detectors and overall platform design. Our results demonstrate that theoretical modelling and an experimental evaluation using non-radiogenic chemiluminescence are viable for system testing design parameters and their impact on photon transport. These approaches enable reduced material consumption and requirement for specialist facilities for handling radioactive materials during the prototyping process. This method establishes proof of concept and the first step towards numerical modelling approaches for the design optimisation of microfluidic LoC systems with integrated detectors for the measurement of pure & beta; emitting radionuclides via scintillation-based detection.
引用
收藏
页数:10
相关论文
共 39 条
  • [31] Comparison of roll-to-roll replication approaches for microfluidic and optical functions in lab-on-a-chip diagnostic devices
    Brecher, Christian
    Baum, Christoph
    Bastuck, Thomas
    MICROFLUIDICS, BIOMEMS, AND MEDICAL MICROSYSTEMS XIII, 2015, 9320
  • [32] Numerical investigation on the effect of external varying magnetic field on the mixing of ferrofluid with deionized water inside a microchannel for lab-on-chip systems
    Saadat, Milad
    Ghassemi, Majid
    Shafii, Mohammad Behshad
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2024, 46 (01) : 5000 - 5012
  • [33] Miniaturization of environmental chemical assays in flowing systems:: The lab-on-a-valve approach vis-a-vis lab-on-a-chip microfluidic devices
    Miro, Manuel
    Hansen, Elo Harald
    ANALYTICA CHIMICA ACTA, 2007, 600 (1-2) : 46 - 57
  • [34] Machine learning microfluidic based platform: Integration of Lab-on-Chip devices and data analysis algorithms for red blood cell plasticity evaluation in Pyruvate Kinase Disease monitoring
    Mencattini, A.
    Rizzuto, V.
    Antonelli, G.
    Di Giuseppe, D.
    D'Orazio, M.
    Filippi, J.
    Comes, M. C.
    Casti, P.
    Corrons, J. L. Vives
    Garcia-Bravo, M.
    Segovia, J. C.
    Manu-Pereira, Maria del Mar
    Lopez-Martinez, M. J.
    Samitier, J.
    Martinelli, E.
    SENSORS AND ACTUATORS A-PHYSICAL, 2023, 351
  • [35] Characterization of four functional biocompatible pressure-sensitive adhesives for rapid prototyping of cell-based lab-on-a-chip and organ-on-a-chip systems
    S. R. A. Kratz
    C. Eilenberger
    P. Schuller
    B. Bachmann
    S. Spitz
    P. Ertl
    M. Rothbauer
    Scientific Reports, 9
  • [36] Characterization of four functional biocompatible pressure-sensitive adhesives for rapid prototyping of cell-based lab-on-a-chip and organ-on-a-chip systems
    Kratz, S. R. A.
    Eilenberger, C.
    Schuller, P.
    Bachmann, B.
    Spitz, S.
    Ertl, P.
    Rothbauer, M.
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [37] Numerical investigation on mixing intensification of ferrofluid and deionized water inside a microchannel using magnetic actuation generated by embedded microcoils for lab-on-chip systems
    Saadat, Milad
    Shafii, Mohammad Behshad
    Ghassemi, Majid
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2020, 147
  • [38] Flat fibre and femtosecond laser technology as a novel photonic integration platform for optofluidic based biosensing devices and lab-on-chip applications: Current results and future perspectives
    Kalli, Kyriacos
    Riziotis, Christos
    Posporis, Andreas
    Markos, Christos
    Koutsides, Charalambos
    Ambran, Sumiaty
    Webb, Andrew S.
    Holmes, Christopher
    Gates, James C.
    Sahu, Jayanta K.
    Smith, Peter G. R.
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 209 : 1030 - 1040
  • [39] The way to high volume fabrication of lab-on-a-chip devices - A technological approach for polymer based microfluidic systems with integrated active valves and pumps
    Microsystem Technologies, 70839 Gerlingen, Germany
    不详
    不详
    J. Microelectron. Electron. Packag., 2009, 4 (198-204):