Rapid prototyping Lab-on-Chip devices for the future: A numerical optimisation of bulk optical parameters in microfluidic systems

被引:0
|
作者
Lu, Sarah E. [1 ,5 ]
Morris, Andrew [2 ]
Clinton-Bailey, Geraldine [2 ]
Namiq, Medya [3 ]
Gow, Paul C. [3 ]
Birchill, Antony [2 ,4 ]
Steigenberger, Sebastian [2 ]
Wyatt, James [2 ]
Forrester, Reuben [2 ]
Mowlem, Matthew C. [2 ]
Warwick, Phillip E. [1 ]
机构
[1] Univ Southampton, Natl Oceanog Ctr, European Way, Southampton SO14 3ZH, England
[2] Natl Oceanog Ctr, Ocean Technol & Engn Grp, Southampton SO14 3ZH, England
[3] Univ Southampton, Optoelect Res Ctr, Southampton SO17 1BJ, England
[4] Univ Portsmouth, Sch Environm Geog & Geosci, Portsmouth PO1 2UP, England
[5] Univ Southampton, Fac Environm & Life Sci, Sch Ocean & Earth Sci, Natl Oceanog Ctr, European Way, Southampton S014 3ZH, England
关键词
Lab on Chip; Ray tracing; Optical modelling; Global warming; Radionuclides; Nuclear industry; MINIATURIZED QUALITY-CONTROL; HYDROGEN-PEROXIDE; BETA PARTICLES; PET; RADIONUCLIDES; MANGANESE; WATER; CELL; RADIOCHEMISTRY; SEPARATION;
D O I
10.1016/j.sna.2023.114496
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Nuclear reactor process control is typically monitored for pure & beta;-emitting radionuclides via manual sampling followed by laboratory analysis, leading to delays in data availability and response times. The development of an in situ microfluidic Lab on Chip (LoC) system with integrated detection capable of measuring pure & beta;-emitting radionuclides presents a promising solution, enabling a reduction in occupational exposure and cost of monitoring whilst providing improved temporal resolution through near real-time data acquisition. However, testing prototypes with radioactive sources is time-consuming, requires specialist facilities/equipment, generates contaminated waste, and cannot rapidly evaluate a wide range of designs or configurations. Despite this, modelling multiple design parameters and testing their impact on detection with non-radioactive substitutes has yet to be adopted as best practice. The measurement of pure & beta; emitters in aqueous media relies on the efficient transport of photons generated by the Cherenkov effect or liquid scintillators to the detector. Here we explore the role of numerical modelling to assess the impact of optical cell geometry and design on photon transmission and detection through the microfluidic system, facilitating improved designs to realise better efficiency of integrated detectors and overall platform design. Our results demonstrate that theoretical modelling and an experimental evaluation using non-radiogenic chemiluminescence are viable for system testing design parameters and their impact on photon transport. These approaches enable reduced material consumption and requirement for specialist facilities for handling radioactive materials during the prototyping process. This method establishes proof of concept and the first step towards numerical modelling approaches for the design optimisation of microfluidic LoC systems with integrated detectors for the measurement of pure & beta; emitting radionuclides via scintillation-based detection.
引用
收藏
页数:10
相关论文
共 39 条
  • [21] Solution self-assembly of block copolymers in microfluidic devices: Polymeric drug delivery vehicles manufactured in the lab-on-chip
    Moffitt, Matthew
    Sinton, David
    Bains, Aman
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2016, 251
  • [22] Fabrication of low-cost MEMS microfluidic devices using metal embossing technique on glass for lab-on-chip applications
    Madhankumar, P.
    Sujatha, L.
    Sundar, R.
    Viswanadam, Gautham
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2023, 33 (08)
  • [23] An Energy Efficient Thermally Regulated Optical Spectroscopy Cell for Lab-on-Chip Devices: Applied to Nitrate Detection
    Murphy, Benjamin J.
    Luy, Edward A.
    Panzica, Katerina L.
    Johnson, Gregory
    Sieben, Vincent J.
    MICROMACHINES, 2021, 12 (08)
  • [25] Let there be chip-towards rapid prototyping of microfluidic devices: one-step manufacturing processes
    Waldbaur, Ansgar
    Rapp, Holger
    Laenge, Kerstin
    Rapp, Bastian E.
    ANALYTICAL METHODS, 2011, 3 (12) : 2681 - 2716
  • [26] Toward numerical prototyping of labs-on-chip: modeling for liquid–liquid microfluidic devices for radionuclide extraction
    Gwendolyne Hellé
    Sean Roberston
    Siméon Cavadias
    Clarisse Mariet
    Gérard Cote
    Microfluidics and Nanofluidics, 2015, 19 : 1245 - 1257
  • [27] Sucrose-based fabrication of 3D-networked, cylindrical microfluidic channels for rapid prototyping of lab-on-a-chip and vaso-mimetic devices
    Lee, Jiwon
    Paek, Jungwook
    Kim, Jaeyoun
    LAB ON A CHIP, 2012, 12 (15) : 2638 - 2642
  • [28] Simulation and rapid prototyping of flexible systems-on-a-chip for future mobile communication applications
    Becker, J
    Kabulepa, L
    Renner, FM
    Glesner, M
    11TH IEEE INTERNATIONAL WORKSHOP ON RAPID SYSTEM PROTOTYPING, PROCEEDINGS, 2000, : 160 - 165
  • [29] Toward numerical prototyping of labs-on-chip: modeling for liquid-liquid microfluidic devices for radionuclide extraction
    Helle, Gwendolyne
    Roberston, Sean
    Cavadias, Simeon
    Mariet, Clarisse
    Cote, Gerard
    MICROFLUIDICS AND NANOFLUIDICS, 2015, 19 (05) : 1245 - 1257
  • [30] Microfluidic Network Simulations Enable On-Demand Prediction of Control Parameters for Operating Lab-on-a-Chip-Devices
    Boeke, Julia Sophie
    Kraus, Daniel
    Henkel, Thomas
    PROCESSES, 2021, 9 (08)