Biomechanical study of a new rim plate fixation strategy for two kinds of posterolateral depression patterns of tibial plateau fractures: a finite element analysis

被引:6
|
作者
Zhang, Bin-bin [1 ]
Wang, Bing-hao [1 ]
Mei, Jiong [1 ]
Luo, Cong-feng [1 ]
Zhu, Yi [1 ]
机构
[1] Shanghai Jiao Tong Univ, Dept Orthopaed Surg, Sch Med, Shanghai Peoples Hosp 6, 600 Yishan Rd, Shanghai 200233, Peoples R China
关键词
Tibial plateau fractures; Posterolateral depression fractures; Finite element analysis; Barrel hoop plate; Fracture modeling; INTERNAL-FIXATION; SPLIT FRACTURE; FRAGMENTS; BONE; OSTEOTOMY; STIFFNESS; SCREWS; COLUMN; JOINT; KNEE;
D O I
10.1186/s13018-023-04315-1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
PurposeThe biomechanical capacity of "Barrel Hoop Plate (BHP)" in the treatment of the posterolateral tibial plateau (PL) depression fractures remains unknown. In this study, two kinds of posterolateral tibial plateau depression models involving mild slope-type depression fracture (MSDF) and local sink hole-type depression fracture (LSDF) were created to test and compare the biomechanical capacities of BHP with the other two conventional fixations (Anterolateral Plate and Posterolateral Plate, ALP and PLP) by finite element analysis.MethodsThe 3D models of three kinds of plate-screw systems and the two kinds of PL-depression models (MSDF and LSDF) were created. An axial force of 400N was applied from the distal femur to the tibial plateau. The maximal displacements of the posterolateral fractures (PLFs), the distribution on the PLFs articular surface and key points displacements were measured. Stresses in the fixation complex including the maximal Equivalent (von-Mises) Stress of implants, the max shear stress of PLFs and stiffness of the fixation were calculated.ResultsThe maximal displacement of MSDF was least in Group BHP. The maximal displacement of LSDF was least in Group ALP. In MSDF, BHP showed the best rim fix effect in MSDF, but unsatisfactory results in LSDF. In both MSDF and LSDF, the greatest max Equivalent Stress of the plate and the screw occurred in the PLP system. ALP and BHP showed a comparable stiffness in MSDF and ALP had the strongest stiffness in the fixation of LSDF.ConclusionsIn MSDF, the BHP has the best biomechanical capacity, especially in displacements of key points such as the PL rim, fracture line, and depression center. In LSDF, the ALP system shows the best biomechanical effect. Although the PLP has the best fixation effect on the posterior wall, it is not suitable for PL-depression fracture fixation.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Biomechanical evaluation of two modified intramedullary fixation system for treating unstable femoral neck fractures: A finite element analysis
    Huang, Qiang
    Zhang, CongMing
    Bai, HuanAn
    Wang, Qian
    Li, Zhong
    Lu, Yao
    Ma, Teng
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 11
  • [42] Weightbearing after combined medial and lateral plate fixation of AO/OTA 41-C2 bicondylar tibial plateau fractures: a biomechanical study
    Sorawut Thamyongkit
    Pooyan Abbasi
    Brent G. Parks
    Babar Shafiq
    Erik A. Hasenboehler
    BMC Musculoskeletal Disorders, 23
  • [43] Weightbearing after combined medial and lateral plate fixation of AO/OTA 41-C2 bicondylar tibial plateau fractures: a biomechanical study
    Thamyongkit, Sorawut
    Abbasi, Pooyan
    Parks, Brent G.
    Shafiq, Babar
    Hasenboehler, Erik A.
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [44] Stress and stability of plate-screw fixation and screw fixation in the treatment of Schatzker type IV medial tibial plateau fracture: a comparative finite element study
    Huang, Xiaowei
    Zhi, Zhongzheng
    Yu, Baoqing
    Chen, Fancheng
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2015, 10
  • [45] Stress and stability of plate-screw fixation and screw fixation in the treatment of Schatzker type IV medial tibial plateau fracture: a comparative finite element study
    Xiaowei Huang
    Zhongzheng Zhi
    Baoqing Yu
    Fancheng Chen
    Journal of Orthopaedic Surgery and Research, 10
  • [46] Anterolateral Dual Plate Fixation for Distal Metaphyseal-Diaphyseal Junction Fractures of the Humerus: Biomechanical Finite Element Analysis with Clinical Results
    Ha, Cheungsoo
    Choi, Inrak
    Lee, Jun-Ku
    Oh, Jongbeom
    Ahn, Wooyeol
    Han, Soo-Hong
    CLINICS IN ORTHOPEDIC SURGERY, 2024, 16 (03) : 493 - 505
  • [47] Biomechanical study of two alternative methods for the treatment of vertical femoral neck fractures - A finite element analysis
    Xia, Yutong
    Zhang, Wendong
    Hu, Hai
    Yan, Lianqi
    Zhan, Shi
    Wang, Jingcheng
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2021, 211
  • [48] Biomechanical evaluation of various internal fixation patterns for unilateral mandibular condylar base fractures: A three-dimensional finite element analysis
    Li, Jie
    Jiao, Jian
    Luo, Ting
    Wu, Wei
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2022, 133
  • [49] Biomechanical effect of anterior talofibular ligament injury in Weber B lateral malleolus fractures after lateral plate fixation: A finite element analysis
    Zhou, Lin
    Lin, Jiaming
    Wang, Bata
    Gan, Weidong
    Huang, Anfei
    Lin, Yongxin
    FOOT AND ANKLE SURGERY, 2020, 26 (08) : 871 - 875
  • [50] Biomechanical analysis of the effect of postero-latero-central tibial plateau fractures in the knee joint: Can posterior soft tissues prevent instability? A finite element study.
    Sisella, Mattia
    Hoekstra, Harm
    Bori, Edoardo
    Innocenti, Bernardo
    CLINICAL BIOMECHANICS, 2024, 120