Biomechanical study of a new rim plate fixation strategy for two kinds of posterolateral depression patterns of tibial plateau fractures: a finite element analysis

被引:6
|
作者
Zhang, Bin-bin [1 ]
Wang, Bing-hao [1 ]
Mei, Jiong [1 ]
Luo, Cong-feng [1 ]
Zhu, Yi [1 ]
机构
[1] Shanghai Jiao Tong Univ, Dept Orthopaed Surg, Sch Med, Shanghai Peoples Hosp 6, 600 Yishan Rd, Shanghai 200233, Peoples R China
关键词
Tibial plateau fractures; Posterolateral depression fractures; Finite element analysis; Barrel hoop plate; Fracture modeling; INTERNAL-FIXATION; SPLIT FRACTURE; FRAGMENTS; BONE; OSTEOTOMY; STIFFNESS; SCREWS; COLUMN; JOINT; KNEE;
D O I
10.1186/s13018-023-04315-1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
PurposeThe biomechanical capacity of "Barrel Hoop Plate (BHP)" in the treatment of the posterolateral tibial plateau (PL) depression fractures remains unknown. In this study, two kinds of posterolateral tibial plateau depression models involving mild slope-type depression fracture (MSDF) and local sink hole-type depression fracture (LSDF) were created to test and compare the biomechanical capacities of BHP with the other two conventional fixations (Anterolateral Plate and Posterolateral Plate, ALP and PLP) by finite element analysis.MethodsThe 3D models of three kinds of plate-screw systems and the two kinds of PL-depression models (MSDF and LSDF) were created. An axial force of 400N was applied from the distal femur to the tibial plateau. The maximal displacements of the posterolateral fractures (PLFs), the distribution on the PLFs articular surface and key points displacements were measured. Stresses in the fixation complex including the maximal Equivalent (von-Mises) Stress of implants, the max shear stress of PLFs and stiffness of the fixation were calculated.ResultsThe maximal displacement of MSDF was least in Group BHP. The maximal displacement of LSDF was least in Group ALP. In MSDF, BHP showed the best rim fix effect in MSDF, but unsatisfactory results in LSDF. In both MSDF and LSDF, the greatest max Equivalent Stress of the plate and the screw occurred in the PLP system. ALP and BHP showed a comparable stiffness in MSDF and ALP had the strongest stiffness in the fixation of LSDF.ConclusionsIn MSDF, the BHP has the best biomechanical capacity, especially in displacements of key points such as the PL rim, fracture line, and depression center. In LSDF, the ALP system shows the best biomechanical effect. Although the PLP has the best fixation effect on the posterior wall, it is not suitable for PL-depression fracture fixation.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Different internal fixation methods for Hoffa-like fractures of the tibial plateau: a finite element analysis
    Xue, Hang
    Deng, Junrong
    Zhang, Zhenhe
    Knoedler, Samuel
    Panayi, Adriana C.
    Knoedler, Leonard
    Mi, Bobin
    Liu, Mengfei
    Dai, Guandong
    Liu, Guohui
    FRONTIERS IN MEDICINE, 2023, 10
  • [22] Optimal Design and Biomechanical Analysis of a Biomimetic Lightweight Design Plate for Distal Tibial Fractures: A Finite Element Analysis
    Wang, Mian
    Deng, Yuping
    Xie, Pusheng
    Tan, Jinchuan
    Yang, Yang
    Ouyang, Hanbin
    Zhao, Dongliang
    Huang, Gang
    Huang, Wenhua
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2022, 10
  • [23] Finite Element Analysis of Two Patterns of Internal Fixation of the Mandibular Subcondylar Fractures (Comparative Study)
    Shouman, Hossam Abdelraouf
    Metwally, Kamal Ghamry
    Elhadidi, Yasser
    Abd el Wahed, Heba
    JOURNAL OF MAXILLOFACIAL & ORAL SURGERY, 2025, 24 (01): : 123 - 129
  • [24] Biomechanical comparison of plate-screw and screw fixation in medial tibial plateau fractures (Schatzker 4). A model study
    Cift, H.
    Cetik, O.
    Kalaycioglu, B.
    Dirikoglu, M. H.
    Ozkan, K.
    Eksioglu, F.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2010, 96 (03) : 263 - 267
  • [25] Effects of plate contouring quality on the biomechanical performance of high tibial osteotomy fixation: A parametric finite element study
    Hayatbakhsh, Zahra
    Farahmand, Farzam
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2022, 236 (03) : 356 - 366
  • [26] Importance of the Posterior Plate in Three-Column Tibial Plateau Fractures: A Finite Element Analysis and Clinical Validation
    Liu, Chen-dong
    Hu, Sun-jun
    Chang, Shi-Min
    Du, Shou-chao
    Xiong, Wen-feng
    Chu, Yong-qian
    ORTHOPAEDIC SURGERY, 2024, 16 (04) : 930 - 942
  • [27] Biomechanical study of four kinds of percutaneous screw fixation in two types of unilateral sacroiliac joint dislocation: A finite element analysis
    Zhang, Lihai
    Peng, Ye
    Dub, Chengfei
    Tang, Peifu
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2014, 45 (12): : 2055 - 2059
  • [28] Comparison between external locking plate fixation and conventional external fixation for extraarticular proximal tibial fractures: a finite element analysis
    Blazevic, Dejan
    Kodvanj, Janos
    Adamovic, Petra
    Vidovic, Dinko
    Trobonjaca, Zlatko
    Sabalic, Srecko
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2022, 17 (01)
  • [29] Comparison between external locking plate fixation and conventional external fixation for extraarticular proximal tibial fractures: a finite element analysis
    Dejan Blažević
    Janoš Kodvanj
    Petra Adamović
    Dinko Vidović
    Zlatko Trobonjača
    Srećko Sabalić
    Journal of Orthopaedic Surgery and Research, 17
  • [30] Finite element analysis and biomechanical study of "sandwich" fixation in the treatment of elderly proximal humerus fractures
    Lv, Yang
    Zhang, Ziyan
    Qv, Ji
    Sheng, Qian
    Zhang, Jian
    Piao, Chengdong
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2024, 12