A Novel Protection Strategy for Single Pole-to-Ground Fault in Multi-Terminal DC Distribution Network

被引:3
|
作者
Yang, Ruixiong [1 ]
Fang, Ke [2 ]
Chen, Jianfu [1 ]
Chen, Yong [1 ]
Liu, Min [2 ]
Meng, Qingxu [2 ]
机构
[1] Guangdong Power Grid Co Ltd, DC Power Distribut & Consumpt Technol Res Ctr, Zhuhai 519099, Peoples R China
[2] Jinan Univ, Energy & Elect Res Ctr, Zhuhai 519070, Peoples R China
关键词
distribution network; single pole-to-ground (SPG) fault; multi-terminal DC; MMC; protection strategy; current derivative; DESIGN;
D O I
10.3390/en16062921
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The single pole-to-ground (SPG) fault is one of critical failures which will have a serious impact on the stable operation of the multi-terminal DC distribution network based on the modular multilevel converter (MMC). It is very significant to analyze fault characteristics for detecting faults and protection design. This paper established the DC SPG fault model, which showed that in the presence of a reactor, the short-circuit current was reduced from 2.3 kA to 1 kA at 6 ms after the fault. Then, a novel SPG fault protection strategy was proposed, which detected the current derivative in connection transformer grounding branch. When the value increases past the threshold of current derivative, small resistance was switched on to increase fault current. Thus, the reliability of differential protection was enhanced. Compared with the traditional protection method, the proposed method does not need communication, and improved the speed of protection. Finally, the simulation model was established in PSCAD/EMTDC. The model included three converter stations: T1, T2 and T3. Among them, T1 outputs power, and T2 and T3 receive power. The results of RTDS showed that the DC circuit breaker operated within 3 ms, the three-port circuit breaker worked within 50 ms, which proves that the proposed strategy was effective. At this time, the system switched from the T1-T2-T3 three-terminal networking operation mode to the T1-T2 two-terminal hand-in-hand operation mode. Since the T3 terminal no longer received power, the transmission power of the T1 terminal decreased, and the received power of the T2 terminal remained unchanged.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Single pole-to-ground fault analysis of MMC DC transmission lines based on inductance fuzzy identification
    An N.
    Shu H.
    Guo Y.
    Yang B.
    Cao P.
    Bo Z.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2021, 41 (03): : 71 - 77
  • [32] Impact of DC Side Fault Protection on Performance and Operation of Multi-Terminal DC (MTDC) Systems
    Mobarrez, Maziar
    Acharya, S.
    Bhattacharya, S.
    2018 THIRTEENTH INTERNATIONAL CONFERENCE ON ECOLOGICAL VEHICLES AND RENEWABLE ENERGIES (EVER), 2018,
  • [33] A Protection Strategy for Fault Detection and Location for Multi-Terminal MVDC Distribution Systems with Renewable Energy Systems
    Monadi, Mehdi
    Koch-Ciobotaru, Cosmin
    Luna, Alvaro
    Candela, Jose Ignacio
    Rodriguez, Pedro
    2014 INTERNATIONAL CONFERENCE ON RENEWABLE ENERGY RESEARCH AND APPLICATION (ICRERA), 2014, : 496 - 501
  • [34] Pole-to-Ground Fault Analysis in Transmission Line of DC Grids Based on VSC
    Wang, Yi
    Zhang, Ziguang
    Fu, Yuan
    Hei, Yang
    Zhang, Xiangyu
    2016 IEEE 8TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE (IPEMC-ECCE ASIA), 2016,
  • [35] Protection Strategy of Single-pole Grounding Fault in DC Distribution System Based on Coordination of Control and Protection
    Wang S.
    Wang Z.
    Liu Q.
    Chen Q.
    Yang J.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2020, 44 (17): : 120 - 126
  • [36] Multi-Frequency bands based Pole-to-Ground fault detection method for MMC-Based radial DC distribution systems
    Yang, Changqing
    Lin, Shuyue
    Guo, Moufa
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2022, 141
  • [37] An Adaptive Reclosing Technology for DC Pole-to-ground Fault Based on DC Current Limiting Circuit
    Wang C.
    Lu J.
    Hong W.
    Xin Y.
    Li B.
    Dianwang Jishu/Power System Technology, 2023, 47 (12): : 4877 - 4886
  • [38] Fault Localization in Multi-Terminal DC Distribution Networks Based on PSO Algorithm
    Wang, Mingyuan
    Xu, Yan
    ELECTRONICS, 2024, 13 (17)
  • [39] A pole-to-ground fault location method for DC distribution network based on high-frequency zero-mode current sparsity
    Wang, He
    Lu, Yu
    Li, Shiqiang
    Yu, Huanan
    Bian, Jing
    ELECTRIC POWER SYSTEMS RESEARCH, 2023, 225
  • [40] Reliability Assessment of AC Distribution Network with Multi-terminal DC Interconnection
    Cheng, Lin
    Wang, Xu
    Chang, Yao
    Song, Fulong
    Gao, Yi
    Wang, Ying
    2016 INTERNATIONAL CONFERENCE ON PROBABILISTIC METHODS APPLIED TO POWER SYSTEMS (PMAPS), 2016,