Measurement of CO2 Isotopologue Ratios Using a Hollow Waveguide-Based Mid-Infrared Dispersion Spectrometer

被引:7
|
作者
Zhang, Haojie [1 ]
Wu, Tao [1 ]
Wu, Qiang [1 ,2 ]
Chen, Weidong [3 ]
Ye, Chenwen [1 ]
Wang, Mengyu [1 ]
He, Xingdao [1 ]
机构
[1] Nanchang Hangkong Univ, Key Lab Nondestruct Test, Minist Educ, Nanchang 330063, Peoples R China
[2] Northumbria Univ, Dept Math Phys & Elect Engn, Newcastle Upon Tyne NE1 8ST, England
[3] Univ Littoral Cote dOpale, Lab Physicochimie Atmosphere, 189A Ave Maurice Schumann, F-59140 Dunkerque, France
基金
中国国家自然科学基金;
关键词
PHASE-SENSITIVE DETECTION; SIDE-BAND HETERODYNE; ISOTOPE ANALYSIS; CARBON-DIOXIDE; BREATH CO2; MU-M; LASER; SPECTROSCOPY; ABSORPTION; MODULATION;
D O I
10.1021/acs.analchem.3c03722
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We demonstrate for the first time the measurement of CO2 isotope ratios (C-13/C-12 and O-18/O-16) in a hollow waveguide (HWG) fiber using a mid-infrared heterodyne phase-sensitive dispersion spectrometer (HPSDS). A 4.329 mu m interband cascade laser is used to target the absorption lines of three CO2 isotopes ((CO2)-C-13-O-16, (OCO)-O-18-C-12-O-16, and (CO2)-C-12-O-16) in a 1 m long and 1 mm inner diameter HWG fiber. The detection limits are 0.29 ppm, 65.78 ppb, and 14.65 ppm with an integration time of 218 s for (CO2)-C-13-O-16, (OCO)-O-18-C-12-O-16, and (CO2)-C-12-O-16, respectively, at a modulation frequency of 160 MHz and a pressure of 230 mbar. The measurement precisions of delta C-13 and delta O-18 are 0.89 and 0.88 parts per thousand, respectively, corresponding to an integration time of 167 s. An experimental comparison between a HPSDS and a built wavelength modulation system with second-harmonic detection (WMS-2f) is conducted. The results show that compared to the WMS-2f, the developed HPSDS exhibits a greater linear dynamic range and excellent long-term stability. This work aims to demonstrate a detection technique of CO2 isotope dispersion spectroscopy with a large dynamic range for relevant applications focusing on samples with high concentrations of CO2 (% volume fraction), such as respiratory analysis in medical diagnostics.
引用
收藏
页码:18479 / 18486
页数:8
相关论文
共 50 条
  • [41] Fast In Situ Airborne Measurement of Ammonia Using a Mid-Infrared Off-Axis ICOS Spectrometer
    Leen, J. Brian
    Yu, Xiao-Ying
    Gupta, Manish
    Baer, Douglas S.
    Hubbe, John M.
    Kluzek, Celine D.
    Tomlinson, Jason M.
    Hubbell, Mike R., II
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2013, 47 (18) : 10446 - 10453
  • [42] Phonon-Enhanced Mid-Infrared CO2 Gas Sensing Using Boron Nitride Nanoresonators
    Bareza, Nestor, Jr.
    Paulillo, Bruno
    Slipchenko, Tetiana M.
    Autore, Marta
    Dolado, Irene
    Liu, Song
    Edgar, James H.
    Velez, Saul
    Martin-Moreno, Luis
    Hillenbrand, Rainer
    Pruneri, Valerio
    ACS PHOTONICS, 2022, 9 (01) : 34 - 42
  • [43] Integration of blue–green electroluminescence structure in mid-infrared hollow optical fiber for targeting invisible CO2 laser beam
    Yang Shen
    Guishun Li
    Guoxing Xie
    Changkun She
    Chengbin Jing
    Junhao Chu
    Optical and Quantum Electronics, 2022, 54
  • [44] Design of an optical gas sensor based on chalcogenide (ChG) glass platform in the mid-infrared for detection of CO2 and CO
    Benkohaila, Nouhaila
    Lorrain, Nathalie
    Bahsine, Saida
    Lmai, Fatima
    Charrier, Joel
    OPTICAL AND QUANTUM ELECTRONICS, 2024, 56 (10)
  • [45] Real-time monitoring of ozone in air using substrate-integrated hollow waveguide mid-infrared sensors
    da Silveira Petruci, Joao Flavio
    Fortes, Paula Regina
    Kokoric, Vjekoslav
    Wilk, Andreas
    Raimundo, Ivo Milton, Jr.
    Cardoso, Arnaldo Alves
    Mizaikoff, Boris
    SCIENTIFIC REPORTS, 2013, 3
  • [46] Real-time monitoring of ozone in air using substrate-integrated hollow waveguide mid-infrared sensors
    João Flávio da Silveira Petruci
    Paula Regina Fortes
    Vjekoslav Kokoric
    Andreas Wilk
    Ivo Milton Raimundo
    Arnaldo Alves Cardoso
    Boris Mizaikoff
    Scientific Reports, 3
  • [47] Mid-infrared gas absorption spectroscopy using a silicon germanium waveguide based chirped supercontinuum
    Munsaka, Proficiency
    Baricholo, Peter
    VIBRATIONAL SPECTROSCOPY, 2024, 133
  • [48] Compact Mid-Infrared Spectrometer Using Continuously Variable Infrared Filter and Microbolometer Array for Simple and Fast Measurement of Molecular Mid-IR Spectra
    Jeon, Taeyoon
    Nateghi, Amirhossein
    Choi, Changsoon
    Jewell, Jack
    Scherer, Axel
    ADVANCED OPTICAL MATERIALS, 2024, 12 (12):
  • [49] Multifunctional mid-infrared photonic switch using a MEMS-based tunable waveguide coupler
    Qiao, Qifeng
    Yazici, Mahmut Sami
    Dong, Bowei
    Liu, Xinmiao
    Lee, Chengkuo
    Zhou, Guangya
    OPTICS LETTERS, 2020, 45 (19) : 5620 - 5623
  • [50] Preparation and transmission characteristics of a mid-infrared attenuated total reflection hollow waveguide based on a stainless steel capillary tube
    Wang, Xu
    Guo, Hong
    Wang, Lin
    Yue, Fangyu
    Jing, Chengbin
    Chu, Junhao
    APPLIED OPTICS, 2016, 55 (23) : 6404 - 6409