Measurement of CO2 Isotopologue Ratios Using a Hollow Waveguide-Based Mid-Infrared Dispersion Spectrometer

被引:7
|
作者
Zhang, Haojie [1 ]
Wu, Tao [1 ]
Wu, Qiang [1 ,2 ]
Chen, Weidong [3 ]
Ye, Chenwen [1 ]
Wang, Mengyu [1 ]
He, Xingdao [1 ]
机构
[1] Nanchang Hangkong Univ, Key Lab Nondestruct Test, Minist Educ, Nanchang 330063, Peoples R China
[2] Northumbria Univ, Dept Math Phys & Elect Engn, Newcastle Upon Tyne NE1 8ST, England
[3] Univ Littoral Cote dOpale, Lab Physicochimie Atmosphere, 189A Ave Maurice Schumann, F-59140 Dunkerque, France
基金
中国国家自然科学基金;
关键词
PHASE-SENSITIVE DETECTION; SIDE-BAND HETERODYNE; ISOTOPE ANALYSIS; CARBON-DIOXIDE; BREATH CO2; MU-M; LASER; SPECTROSCOPY; ABSORPTION; MODULATION;
D O I
10.1021/acs.analchem.3c03722
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We demonstrate for the first time the measurement of CO2 isotope ratios (C-13/C-12 and O-18/O-16) in a hollow waveguide (HWG) fiber using a mid-infrared heterodyne phase-sensitive dispersion spectrometer (HPSDS). A 4.329 mu m interband cascade laser is used to target the absorption lines of three CO2 isotopes ((CO2)-C-13-O-16, (OCO)-O-18-C-12-O-16, and (CO2)-C-12-O-16) in a 1 m long and 1 mm inner diameter HWG fiber. The detection limits are 0.29 ppm, 65.78 ppb, and 14.65 ppm with an integration time of 218 s for (CO2)-C-13-O-16, (OCO)-O-18-C-12-O-16, and (CO2)-C-12-O-16, respectively, at a modulation frequency of 160 MHz and a pressure of 230 mbar. The measurement precisions of delta C-13 and delta O-18 are 0.89 and 0.88 parts per thousand, respectively, corresponding to an integration time of 167 s. An experimental comparison between a HPSDS and a built wavelength modulation system with second-harmonic detection (WMS-2f) is conducted. The results show that compared to the WMS-2f, the developed HPSDS exhibits a greater linear dynamic range and excellent long-term stability. This work aims to demonstrate a detection technique of CO2 isotope dispersion spectroscopy with a large dynamic range for relevant applications focusing on samples with high concentrations of CO2 (% volume fraction), such as respiratory analysis in medical diagnostics.
引用
收藏
页码:18479 / 18486
页数:8
相关论文
共 50 条
  • [11] Photoacoustic Detection of CO2 Based on Mid-Infrared LED
    Li Zhengang
    Si Ganshang
    Ning Zhiqiang
    Liu Jiaxiang
    Fang Yonghua
    Cheng Zhen
    Si Beibei
    Yang Changping
    ACTA OPTICA SINICA, 2022, 42 (13)
  • [12] Multivariate determination of 13CO2/12CO2 ratios in exhaled mouse breath with mid-infrared hollow waveguide gas sensors
    Felicia Seichter
    Andreas Wilk
    Katharina Wörle
    Seong-Soo Kim
    Josef A. Vogt
    Ulrich Wachter
    Peter Radermacher
    Boris Mizaikoff
    Analytical and Bioanalytical Chemistry, 2013, 405 : 4945 - 4951
  • [13] Multivariate determination of 13CO2/12CO2 ratios in exhaled mouse breath with mid-infrared hollow waveguide gas sensors
    Seichter, Felicia
    Wilk, Andreas
    Woerle, Katharina
    Kim, Seong-Soo
    Vogt, Josef A.
    Wachter, Ulrich
    Radermacher, Peter
    Mizaikoff, Boris
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (14) : 4945 - 4951
  • [14] Simultaneous measurement of 13C-,18O-, and 17O- isotopes of CO2 using a compact mid-infrared hollow waveguide gas sensor
    Huang, Wenbiao
    Zhang, Zhirong
    Xia, Hua
    Wang, Qianjin
    Sun, Pengshuai
    Pang, Tao
    Wu, Bian
    SENSORS AND ACTUATORS B-CHEMICAL, 2024, 417
  • [15] A novel mid-infrared hollow waveguide gas sensor for measuring water vapor isotope ratios in the atmosphere
    Liu, Yang
    Wu, Tao
    Wu, Qiang
    Chen, Weidong
    Ye, Chenwen
    Wang, Mengyu
    He, Xingdao
    SENSORS AND ACTUATORS B-CHEMICAL, 2023, 375
  • [16] Mid-infrared dissolved CO2 measurement system using the ultra-compact multipass cell
    Chen, Hongda
    Chen, Chen
    Dong, Weihao
    Li, Yongyang
    Zhang, Mengru
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2023, 65 (05) : 1319 - 1323
  • [17] Silane-Modified Mesoporous Silica Nanocoatings for Selective Mid-Infrared Waveguide-Based Gas Sensing
    Al Husseini, Diana
    Zhou, Junchao
    Li, Junyan
    Gutierrez-Osuna, Ricardo
    Cote, Gerard L.
    Lin, Pao Tai
    Sukhishvili, Svetlana A.
    ADVANCED MATERIALS INTERFACES, 2022, 9 (34)
  • [18] Mid-Infrared Spectrometer Based on Tunable Photoresponses in Pdse2
    Lee, Jea Jung
    Levi, Adi
    Naveh, Doron
    Xia, Fengnian
    International Journal of High Speed Electronics and Systems, 2024, 33 (2-3)
  • [19] Measurement of Chalcogenide Glass Optical Dispersion Using a Mid-Infrared Prism Coupler
    Qiao, Hong A.
    Anheier, Norm C.
    Musgraves, J. David
    Richardson, Kathleen
    Hewak, Daniel W.
    WINDOW AND DOME TECHNOLOGIES AND MATERIALS XII, 2011, 8016
  • [20] Photoacoustic spectrometer based on CO2 waveguide laser
    Yu, Q.X.
    Chen, Z.B.
    Li, H.
    Li, S.C.
    Lin, J.X.
    Jiguang Zazhi/Laser Journal, 2001, 22 (04):