Maxillary molar distalization treated with clear aligners combined with mini-implants and angel button using different traction force: a finite element study

被引:1
|
作者
Cui, Jiayu [1 ]
Yao, Chengliang [1 ]
Zhang, Zheyuan [1 ]
Zhang, Tong [1 ]
Cao, Yuxin [1 ]
Liu, Ting [1 ]
Li, Bing [1 ]
Wu, Xiuping [1 ]
机构
[1] Shanxi Med Univ, Stomatol Hosp, Sch Stomatol, Dept Orthodont, Jinzhong, Shanxi, Peoples R China
关键词
Clear aligner; finite element analysis; mini-implants; molar distalization; CLASS-II MALOCCLUSION; PERIODONTAL-LIGAMENT; BONE THICKNESS; ANCHORAGE; ELASTICS; TISSUE;
D O I
10.1080/10255842.2023.2183735
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
ObjectivesTo evaluate the biomechanical system of molar distalization with clear aligner therapy (CAT) combined with angel button using interradicular mini-implants (IRMIs) with varying elastic forces.Materials and MethodsFE models including maxilla, complete maxillary dentition, periodontal ligaments (PDL), composite attachments, mini-implants (MI), and dedicated orthodontic aligner, were constructed. Three groups were created in accordance with the sagittal position of MI. Elastic forces (0 N,1 N,1.5 N,2 N) were applied.ResultsCAT without elastics caused labial tipping and intrusion of the anterior teeth. Initial labial tipping and the von Mises stress of the maxillary anterior teeth decreased as the elastic forces increased.
引用
收藏
页码:296 / 305
页数:10
相关论文
共 48 条
  • [41] Evaluation of different models of intrusive force application and temporary anchorage device (TAD) placement in total arch intrusion using clear aligners; a finite element analysis
    Allahyar Geramy
    Soroush Ebrahimi
    BMC Oral Health, 23
  • [42] Effect of Different Anchorage Reinforcement Methods on Long-Term Maxillary Whole Arch Distalization with Clear Aligner: A 4D Finite Element Study with Staging Simulation
    Mao, Bochun
    Tian, Yajing
    Xiao, Yujia
    Liu, Jiayi
    Liu, Dawei
    Zhou, Yanheng
    Li, Jing
    BIOENGINEERING-BASEL, 2024, 11 (01):
  • [43] Correction: Evaluation of different models of intrusive force application and temporary anchorage device (TAD) placement in total arch intrusion using clear aligners; a finite element analysis
    Allahyar Geramy
    Soroush Ebrahimi
    BMC Oral Health, 23 (1)
  • [44] Anchorage loss of the posterior teeth under different extraction patterns in maxillary and mandibular arches using clear aligner: a finite element study
    Qiang, Ruyue
    Gao, Jie
    Wang, Yanqi
    Wang, Wei
    Ma, Yanning
    Jin, Zuolin
    BMC ORAL HEALTH, 2024, 24 (01):
  • [45] Analysis of stress distribution in lingual orthodontics system for effective en-masse retraction using various combinations of lever arm and mini-implants: A finite element method study
    Kushwah, Ashish
    Kumar, Mukesh
    Goyal, Manish
    Premsagar, Shruti
    Rani, Shikha
    Sharma, Sonika
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2020, 158 (06) : E161 - E172
  • [46] Three-Dimensional Finite Element Study of Endodontically Treated Maxillary Central Incisors Restored Using Different Post and Crown Materials
    Kharboutly, Nour Al-Deen
    Allaf, Mirza
    Kanout, Shaza
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (01)
  • [47] Maxillary anterior en masse retraction using different antero-posterior position of mini screw: a 3D finite element study
    Zohreh Hedayati
    Mehrdad Shomali
    Progress in Orthodontics, 17
  • [48] Maxillary anterior en masse retraction using different antero-posterior position of mini screw: a 3D finite element study
    Hedayati, Zohreh
    Shomali, Mehrdad
    PROGRESS IN ORTHODONTICS, 2016, 17 : 31