Maxillary molar distalization treated with clear aligners combined with mini-implants and angel button using different traction force: a finite element study

被引:1
|
作者
Cui, Jiayu [1 ]
Yao, Chengliang [1 ]
Zhang, Zheyuan [1 ]
Zhang, Tong [1 ]
Cao, Yuxin [1 ]
Liu, Ting [1 ]
Li, Bing [1 ]
Wu, Xiuping [1 ]
机构
[1] Shanxi Med Univ, Stomatol Hosp, Sch Stomatol, Dept Orthodont, Jinzhong, Shanxi, Peoples R China
关键词
Clear aligner; finite element analysis; mini-implants; molar distalization; CLASS-II MALOCCLUSION; PERIODONTAL-LIGAMENT; BONE THICKNESS; ANCHORAGE; ELASTICS; TISSUE;
D O I
10.1080/10255842.2023.2183735
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
ObjectivesTo evaluate the biomechanical system of molar distalization with clear aligner therapy (CAT) combined with angel button using interradicular mini-implants (IRMIs) with varying elastic forces.Materials and MethodsFE models including maxilla, complete maxillary dentition, periodontal ligaments (PDL), composite attachments, mini-implants (MI), and dedicated orthodontic aligner, were constructed. Three groups were created in accordance with the sagittal position of MI. Elastic forces (0 N,1 N,1.5 N,2 N) were applied.ResultsCAT without elastics caused labial tipping and intrusion of the anterior teeth. Initial labial tipping and the von Mises stress of the maxillary anterior teeth decreased as the elastic forces increased.
引用
收藏
页码:296 / 305
页数:10
相关论文
共 48 条
  • [31] Effects of upper-molar distalization using clear aligners in combination with Class II elastics: a three-dimensional finite element analysis
    Xulin Liu
    Yuxun Cheng
    Wen Qin
    Shishu Fang
    Wei Wang
    Yanning Ma
    Zuolin Jin
    BMC Oral Health, 22
  • [32] Effects of upper-molar distalization using clear aligners in combination with Class II elastics: a three-dimensional finite element analysis
    Liu, Xulin
    Cheng, Yuxun
    Qin, Wen
    Fang, Shishu
    Wang, Wei
    Ma, Yanning
    Jin, Zuolin
    BMC ORAL HEALTH, 2022, 22 (01)
  • [33] Effects of overtreatment with different attachment positions on maxillary anchorage enhancement with clear aligners: a finite element analysis study
    Shiyu Wang
    Yangyang Huang
    Dian Fan
    Hao Liu
    Changyong Yuan
    Li Yang
    Penglai Wang
    BMC Oral Health, 23
  • [34] Effects of overtreatment with different attachment positions on maxillary anchorage enhancement with clear aligners: a finite element analysis study
    Wang, Shiyu
    Huang, Yangyang
    Fan, Dian
    Liu, Hao
    Yuan, Changyong
    Yang, Li
    Wang, Penglai
    BMC ORAL HEALTH, 2023, 23 (01)
  • [35] Analysis of a force system for upper molar distalization using a trans-palatal arch and mini-implant: a finite element analysis study
    Ueno, Satoshi
    Motoyoshi, Mitsuru
    Mayahara, Kotoe
    Saito, Yoko
    Akiyama, Yuko
    Son, Seil
    Shimizu, Noriyoshi
    EUROPEAN JOURNAL OF ORTHODONTICS, 2013, 35 (05) : 628 - 633
  • [36] Effectiveness of palatal anchorage device (PAD) for maxillary anterior retraction with clear aligners using finite element study
    Lin, Shuang
    Lu, Tong
    Zhang, Hengbing
    Wang, Wei
    Han, Lei
    Mei, Li
    Li, Huang
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [37] Displacement patterns of the maxillary anterior teeth during total distalization and en masse anterior retraction using interradicular and infrazygomatic crest mini-implants with varying power arm heights: A finite element analysis
    Sreenivasagan, Swapna
    Subramanian, Aravind K.
    Chae, Jong M.
    Venugopal, Adith
    Marya, Anand
    JOURNAL OF INTERNATIONAL ORAL HEALTH, 2021, 13 (05): : 462 - 469
  • [38] Effects of different tooth movement patterns and aligner thicknesses on maxillary arch expansion with clear aligners: a three-dimensional finite element study
    Li, Na
    Wang, ChunJuan
    Yang, Min
    Chen, DingGen
    Tang, MingYuan
    Li, DaoKun
    Qiu, ShengLei
    Chen, Qi
    Feng, Yi
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2024, 12
  • [39] Biomechanical analysis of maxillary first molar intrusion using 3D printed personalized device combined with clear aligner: a finite element study and clinical application
    Qin Xue
    Mei Hu
    Minglu Xu
    Xuyang Zhang
    Huaqiao Wang
    Mimi Sun
    Chunjuan Wang
    Yao He
    Clinical Oral Investigations, 29 (5)
  • [40] Evaluation of different models of intrusive force application and temporary anchorage device (TAD) placement in total arch intrusion using clear aligners; a finite element analysis
    Allahyar, Geramy
    Soroush, Ebrahimi
    BMC ORAL HEALTH, 2023, 23 (01)