Innovative experimental animal models for real-time comparison of antithrombogenicity between two oxygenators using dual extracorporeal circulation circuits and indocyanine green fluorescence imaging

被引:0
|
作者
Sakurai, Hironobu [1 ]
Fujiwara, Tatsuki [1 ]
Ohuchi, Katsuhiro [2 ]
Hijikata, Wataru [3 ]
Inoue, Yusuke [4 ]
Maruyama, Osamu [5 ]
Tahara, Tomoki [1 ]
Yokota, Sachie [6 ]
Tanaka, Yui [3 ]
Takewa, Yoshiaki [4 ]
Mizuno, Tomohiro [1 ]
Arai, Hirokuni [1 ]
机构
[1] Tokyo Med & Dent Univ, Grad Sch Med & Dent Sci, Dept Cardiovasc Surg, Tokyo, Japan
[2] Tokyo Med & Dent Univ, Ctr Expt Anim, Tokyo, Japan
[3] Tokyo Inst Technol, Sch Engn, Tokyo, Japan
[4] Asahikawa Med Univ, Adv Med Engn Res Ctr, Asahikawa, Hokkaido, Japan
[5] Natl Inst Adv Ind Sci & Technol, Hlth & Med Res Inst, Tsukuba, Ibaraki, Japan
[6] Tokyo Med & Dent Univ, Fac Med, Tokyo, Japan
基金
日本学术振兴会;
关键词
antithrombotic comparison; COVID-19; dual extracorporeal circulation; experimental animal model; extracorporeal membrane oxygenation; indocyanine green fluorescence imaging; oxygenator; pulsatile flow; CENTRIFUGAL BLOOD PUMP; MEDTECH MAG-LEV; IN-VITRO; MEMBRANE-OXYGENATION; SINGLE-USE; COVID-19; SUPPORT; PORCINE; BYPASS;
D O I
10.1111/aor.14380
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background Antithrombogenicity of extracorporeal membrane oxygenation (ECMO) devices, particularly oxygenators, is a current problem, with numerous studies and developments underway. However, there has been limited progress in developing methods to accurately compare the antithrombogenicity of oxygenators. Animal experiments are commonly conducted to evaluate the antithrombogenicity of devices; however, it is challenging to maintain a steady experimental environment. We propose an innovative experimental animal model to evaluate different devices in a constant experimental environment in real-time. Methods This model uses two venous-arterial ECMO circuits attached to one animal (one by jugular vein and carotid artery, one by femoral vein and artery) and real-time assessment of thrombus formation in the oxygenator by indocyanine green (ICG) fluorescence imaging. Comparison studies were conducted using three pigs: one to compare different oxygenators (MERA vs. CAPIOX) (Case 1), and two to compare antithrombotic properties of the oxygenator (QUADROX) when used under different hydrodynamic conditions (continuous flow vs. pulsatile flow) (Cases 2 and 3). Results Thrombi, visualized using ICG imaging, appeared as black dots on a white background in each oxygenator. In Case 1, differences in the site of thrombus formation and rate of thrombus growth were observed in real-time in two oxygenators. In Case 2 and 3, the thrombus region was smaller in pulsatile than in continuous conditions. Conclusions We devised an innovative experimental animal model for comparison of antithrombogenicity in ECMO circuits. This model enabled simultaneous evaluation of two different ECMO circuits under the same biological conditions and reduced the number of sacrificed experimental animals.
引用
收藏
页码:77 / 87
页数:11
相关论文
共 32 条
  • [21] Does Using Indocyanine Green Fluorescence Imaging for Tumors Help in Determining the Safe Surgical Margin in Real-Time Navigation of Laparoscopic Hepatectomy? A Retrospective Study
    Cai, Xinran
    Hong, Haijie
    Pan, Wei
    Chen, Jiangzhi
    Jiang, Lei
    Du, Qiang
    Li, Ge
    Lin, Shengzhe
    Chen, Yanling
    ANNALS OF SURGICAL ONCOLOGY, 2023, 30 (04) : 1981 - 1987
  • [22] Real-time navigation for laparoscopic hepatectomy using image fusion of preoperative 3D surgical plan and intraoperative indocyanine green fluorescence imaging
    Zhang, Peng
    Luo, Huoling
    Zhu, Wen
    Yang, Jian
    Zeng, Ning
    Fan, Yingfang
    Wen, Sai
    Xiang, Nan
    Jia, Fucang
    Fang, Chihua
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2020, 34 (08): : 3449 - 3459
  • [23] A retrospective pilot study to examine the feasibility of real-time navigation for laparoscopic liver resections in intrahepatic cholangiocarcinoma using fusion indocyanine green fluorescence imaging
    Zhai, Shu-Ting
    Liang, Xiao
    Mao, Qi-Jiang
    Liang, Yue-Long
    Xu, Jun-Jie
    Chen, Jiang
    Shi, Liang
    Xie, Yang-Yang
    Cai, Xiu-Jun
    JOURNAL OF SURGICAL ONCOLOGY, 2020, 122 (02) : 226 - 233
  • [24] Real-time navigation for laparoscopic hepatectomy using image fusion of preoperative 3D surgical plan and intraoperative indocyanine green fluorescence imaging
    Peng Zhang
    Huoling Luo
    Wen Zhu
    Jian Yang
    Ning Zeng
    Yingfang Fan
    Sai Wen
    Nan Xiang
    Fucang Jia
    Chihua Fang
    Surgical Endoscopy, 2020, 34 : 3449 - 3459
  • [25] Lymphatic Reconnection and Restoration of Lymphatic Flow by Nonvascularized Lymph Node Transplantation: Real-Time Fluorescence Imaging Using Indocyanine Green and Fluorescein Isothiocyanate-Dextran
    Maeda, Taku
    Yamamoto, Yuhei
    Iwasaki, Daisuke
    Hayashi, Toshihiko
    Funayama, Emi
    Oyama, Akihiko
    Murao, Naoki
    Furukawa, Hiroshi
    LYMPHATIC RESEARCH AND BIOLOGY, 2018, 16 (02) : 165 - 173
  • [26] Fluorescence imaging for real-time detection of breast cancer tumors using IV injection of indocyanine green with non-conventional imaging: a systematic review of preclinical and clinical studies of perioperative imaging technologies
    Pop, C. Florin
    Veys, Isabelle
    Bormans, Anne
    Larsimont, Denis
    Liberale, Gabriel
    BREAST CANCER RESEARCH AND TREATMENT, 2024, 204 (03) : 429 - 442
  • [27] Fluorescence imaging for real-time detection of breast cancer tumors using IV injection of indocyanine green with non-conventional imaging: a systematic review of preclinical and clinical studies of perioperative imaging technologies
    C. Florin Pop
    Isabelle Veys
    Anne Bormans
    Denis Larsimont
    Gabriel Liberale
    Breast Cancer Research and Treatment, 2024, 204 : 429 - 442
  • [28] ASO Visual Abstract: Whether Using Indocyanine Green Fluorescence Imaging for Tumor Helps Determining Safe Surgical Margin in Real-Time Navigation of Laparoscopic Hepatectomy? A Retrospective Study
    Cai, Xinran
    Hong, Haijie
    Pan, Wei
    Chen, Jiangzhi
    Jiang, Lei
    Du, Qiang
    Li, Ge
    Lin, Shengzhe
    Chen, Yanling
    ANNALS OF SURGICAL ONCOLOGY, 2023, 30 (04) : 1990 - 1990
  • [29] ASO Visual Abstract: Whether Using Indocyanine Green Fluorescence Imaging for Tumor Helps Determining Safe Surgical Margin in Real-Time Navigation of Laparoscopic Hepatectomy? A Retrospective Study
    Xinran Cai
    Haijie Hong
    Wei Pan
    Jiangzhi Chen
    Lei Jiang
    Qiang Du
    Ge Li
    Shengzhe Lin
    Yanling Chen
    Annals of Surgical Oncology, 2023, 30 : 1990 - 1990
  • [30] Real-Time Navigation Guidance Using Fusion Indocyanine Green Fluorescence Imaging in Laparoscopic Non-Anatomical Hepatectomy of Hepatocellular Carcinomas at Segments 6, 7, or 8 (with Videos)
    Zhou, Yu
    Lin, Ye
    Jin, Haosheng
    Hou, Baohua
    Yu, Min
    Yin, Zi
    Jian, Zhixiang