Innovative experimental animal models for real-time comparison of antithrombogenicity between two oxygenators using dual extracorporeal circulation circuits and indocyanine green fluorescence imaging

被引:0
|
作者
Sakurai, Hironobu [1 ]
Fujiwara, Tatsuki [1 ]
Ohuchi, Katsuhiro [2 ]
Hijikata, Wataru [3 ]
Inoue, Yusuke [4 ]
Maruyama, Osamu [5 ]
Tahara, Tomoki [1 ]
Yokota, Sachie [6 ]
Tanaka, Yui [3 ]
Takewa, Yoshiaki [4 ]
Mizuno, Tomohiro [1 ]
Arai, Hirokuni [1 ]
机构
[1] Tokyo Med & Dent Univ, Grad Sch Med & Dent Sci, Dept Cardiovasc Surg, Tokyo, Japan
[2] Tokyo Med & Dent Univ, Ctr Expt Anim, Tokyo, Japan
[3] Tokyo Inst Technol, Sch Engn, Tokyo, Japan
[4] Asahikawa Med Univ, Adv Med Engn Res Ctr, Asahikawa, Hokkaido, Japan
[5] Natl Inst Adv Ind Sci & Technol, Hlth & Med Res Inst, Tsukuba, Ibaraki, Japan
[6] Tokyo Med & Dent Univ, Fac Med, Tokyo, Japan
基金
日本学术振兴会;
关键词
antithrombotic comparison; COVID-19; dual extracorporeal circulation; experimental animal model; extracorporeal membrane oxygenation; indocyanine green fluorescence imaging; oxygenator; pulsatile flow; CENTRIFUGAL BLOOD PUMP; MEDTECH MAG-LEV; IN-VITRO; MEMBRANE-OXYGENATION; SINGLE-USE; COVID-19; SUPPORT; PORCINE; BYPASS;
D O I
10.1111/aor.14380
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background Antithrombogenicity of extracorporeal membrane oxygenation (ECMO) devices, particularly oxygenators, is a current problem, with numerous studies and developments underway. However, there has been limited progress in developing methods to accurately compare the antithrombogenicity of oxygenators. Animal experiments are commonly conducted to evaluate the antithrombogenicity of devices; however, it is challenging to maintain a steady experimental environment. We propose an innovative experimental animal model to evaluate different devices in a constant experimental environment in real-time. Methods This model uses two venous-arterial ECMO circuits attached to one animal (one by jugular vein and carotid artery, one by femoral vein and artery) and real-time assessment of thrombus formation in the oxygenator by indocyanine green (ICG) fluorescence imaging. Comparison studies were conducted using three pigs: one to compare different oxygenators (MERA vs. CAPIOX) (Case 1), and two to compare antithrombotic properties of the oxygenator (QUADROX) when used under different hydrodynamic conditions (continuous flow vs. pulsatile flow) (Cases 2 and 3). Results Thrombi, visualized using ICG imaging, appeared as black dots on a white background in each oxygenator. In Case 1, differences in the site of thrombus formation and rate of thrombus growth were observed in real-time in two oxygenators. In Case 2 and 3, the thrombus region was smaller in pulsatile than in continuous conditions. Conclusions We devised an innovative experimental animal model for comparison of antithrombogenicity in ECMO circuits. This model enabled simultaneous evaluation of two different ECMO circuits under the same biological conditions and reduced the number of sacrificed experimental animals.
引用
收藏
页码:77 / 87
页数:11
相关论文
共 32 条
  • [1] Liver tumor boundaries identified intraoperatively using real-time indocyanine green fluorescence imaging
    Ya-Min Zhang
    Rui Shi
    Jian-Cun Hou
    Zi-Rong Liu
    Zi-Lin Cui
    Yang Li
    Di Wu
    Yuan Shi
    Zhong-Yang Shen
    Journal of Cancer Research and Clinical Oncology, 2017, 143 : 51 - 58
  • [2] Liver tumor boundaries identified intraoperatively using real-time indocyanine green fluorescence imaging
    Zhang, Ya-Min
    Shi, Rui
    Hou, Jian-Cun
    Liu, Zi-Rong
    Cui, Zi-Lin
    Li, Yang
    Wu, Di
    Shi, Yuan
    Shen, Zhong-Yang
    JOURNAL OF CANCER RESEARCH AND CLINICAL ONCOLOGY, 2017, 143 (01) : 51 - 58
  • [3] Pure Laparoscopic Living Donor Right Hepatectomy Using Real-Time Indocyanine Green Fluorescence Imaging
    Kim, Ye Seul
    Choi, Sung Hoon
    JOURNAL OF GASTROINTESTINAL SURGERY, 2019, 23 (08) : 1711 - 1712
  • [4] Pure Laparoscopic Living Donor Right Hepatectomy Using Real-Time Indocyanine Green Fluorescence Imaging
    Ye Seul Kim
    Sung Hoon Choi
    Journal of Gastrointestinal Surgery, 2019, 23 : 1711 - 1712
  • [5] LYMPH NODE DISSECTION FOR COLON CANCER USING THE REAL-TIME INDOCYANINE GREEN FLUORESCENCE IMAGING.
    Sato, Y.
    Okita, K.
    Okuya, K.
    Akizuki, E.
    Hamabe, A.
    Takemasa, I.
    DISEASES OF THE COLON & RECTUM, 2022, 65 (05) : 101 - 101
  • [6] Laparoscopic left hemihepatectomy guided by real-time indocyanine green fluorescence imaging using the arantius-first approach
    Jiaguo Wang
    Jie Xu
    Kai Lei
    Ke You
    Zuojin Liu
    World Journal of Surgical Oncology, 21
  • [7] Laparoscopic duodenum-preserving total pancreatic head resection using real-time indocyanine green fluorescence imaging
    Yunqiang Cai
    Zhenjiang Zheng
    Pan Gao
    Yongbin Li
    Bing Peng
    Surgical Endoscopy, 2021, 35 : 1355 - 1361
  • [8] Laparoscopic left hemihepatectomy guided by real-time indocyanine green fluorescence imaging using the arantius-first approach
    Wang, Jiaguo
    Xu, Jie
    Lei, Kai
    You, Ke
    Liu, Zuojin
    WORLD JOURNAL OF SURGICAL ONCOLOGY, 2023, 21 (01)
  • [9] Laparoscopic duodenum-preserving total pancreatic head resection using real-time indocyanine green fluorescence imaging
    Cai, Yunqiang
    Zheng, Zhenjiang
    Gao, Pan
    Li, Yongbin
    Peng, Bing
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2021, 35 (03): : 1355 - 1361
  • [10] Real-time navigation during hepatectomy using fusion indocyanine green-fluorescence imaging: protocol for a prospective cohort study
    Gon, Hidetoshi
    Komatsu, Shohei
    Murakami, Sae
    Kido, Masahiro
    Tanaka, Motofumi
    Kuramitsu, Kaori
    Tsugawa, Daisuke
    Awazu, Masahide
    Toyama, Hirochika
    Fukumoto, Takumi
    BMJ OPEN, 2019, 9 (08):