Monitoring and apportioning sources of indoor air quality using low-cost particulate matter sensors

被引:28
|
作者
Bousiotis, Dimitrios [1 ]
Alconcel, Leah-Nani S. [2 ]
Beddows, David C. S. [1 ]
Harrison, Roy M. [1 ,3 ]
Pope, Francis D. [1 ]
机构
[1] Univ Birmingham, Sch Geog Earth & Environm Sci, Div Environm Hlth & Risk Management, Birmingham B15 2TT, England
[2] Univ Birmingham, Sch Met & Mat, Birmingham B15 2TT, England
[3] King Abdulaziz Univ, Ctr Excellence Environm Studies, Dept Environm Sci, POB 80203, Jeddah 21589, Saudi Arabia
基金
英国自然环境研究理事会;
关键词
Particulate matter; Source apportionment; Indoor air quality; Exposure; Infiltration; PM2; 5; POSITIVE MATRIX FACTORIZATION; INDOOR/OUTDOOR RELATIONSHIPS; SIZE DISTRIBUTION; BACKGROUND SITE; POLLUTION; URBAN; PARTICLES; PM2.5; HOMES; PERFORMANCE;
D O I
10.1016/j.envint.2023.107907
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Air quality is one of the most important factors in public health. While outdoor air quality is widely studied, the indoor environment has been less scrutinised, even though time spent indoors is typically much greater than outdoors. The emergence of low-cost sensors can help assess indoor air quality. This study provides a new methodology, utilizing low-cost sensors and source apportionment techniques, to understand the relative importance of indoor and outdoor air pollution sources upon indoor air quality. The methodology is tested with three sensors placed in different rooms inside an exemplar house (bedroom, kitchen and office) and one out-doors. When the family was present, the bedroom had the highest average concentrations for PM2.5 and PM10 (3.9 +/- 6.8 ug/m3 and 9.6 +/- 12.7 mu g/m3 respectively), due to the activities undertaken there and the presence of softer furniture and carpeting. The kitchen, while presenting the lowest PM concentrations for both size ranges (2.8 +/- 5.9 ug/m3 and 4.2 +/- 6.9 mu g/m3 respectively), presented the highest PM spikes, especially during cooking times. Increased ventilation in the office resulted in the highest PM1 concentration (1.6 +/- 1.9 mu g/m3), high-lighting the strong effect of infiltration of outdoor air for the smallest particles. Source apportionment, via positive matrix factorisation (PMF), showed that up to 95 % of the PM1 was found to be of outdoor sources in all the rooms. This effect was reduced as particle size increased, with outdoor sources contributing >65 % of the PM2.5, and up to 50 % of the PM10, depending on the room studied. The new approach to elucidate the con-tributions of different sources to total indoor air pollution exposure, described in this paper, is easily scalable and translatable to different indoor locations.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Can data reliability of low-cost sensor devices for indoor air particulate matter monitoring be improved?-An approach using machine learning
    Chojer, H.
    Branco, P. T. B. S.
    Martins, F. G.
    Alvim-Ferraz, M. C. M.
    Sousa, S. I. V.
    ATMOSPHERIC ENVIRONMENT, 2022, 286
  • [32] ekoNET - Environmental Monitoring using Low-cost Sensors for Detecting Gases, Particulate Matter and Meteorological Parameters
    Pokric, Boris
    Kreo, Srdan
    Drajic, Dejan
    Pokric, Maja
    Jokic, Ivan
    Jovasevic-Stojanovic, Milena
    2014 EIGHTH INTERNATIONAL CONFERENCE ON INNOVATIVE MOBILE AND INTERNET SERVICES IN UBIQUITOUS COMPUTING (IMIS), 2014, : 421 - 426
  • [33] Development of an air quality station using low-cost sensors
    Roncaglio, Mateus Maruzka
    de Camargo, Edson Tavares
    Martins, Leila Droprinchinski
    Oyamada, Marcio Seiji
    2023 XIII BRAZILIAN SYMPOSIUM ON COMPUTING SYSTEMS ENGINEERING, SBESC, 2023,
  • [34] A low-cost image sensor for particulate matter detection to streamline Citizen Science campaigns on Air Quality Monitoring
    Ali Shah, Syed Mohsin
    Casado-Mansilla, Diego
    Lopez-de-Ipina, Diego
    Illueca Fernandez, Eduardo
    Hassani, AmirHossein
    Pujante Perez, Alejandro
    2024 9TH INTERNATIONAL CONFERENCE ON SMART AND SUSTAINABLE TECHNOLOGIES, SPLITECH 2024, 2024,
  • [35] Application of the low-cost sensing technology for indoor air quality monitoring: A review
    Sa, Juliana P.
    Alvim-Ferraz, Maria Conceicao M.
    Martins, Fernando G.
    Sousa, Sofia I., V
    ENVIRONMENTAL TECHNOLOGY & INNOVATION, 2022, 28
  • [36] Development of low-cost indoor air quality monitoring devices: Recent advancements
    Chojer, H.
    Branco, P. T. B. S.
    Martins, F. G.
    Alvim-Ferraz, M. C. M.
    Sousa, S. I., V
    SCIENCE OF THE TOTAL ENVIRONMENT, 2020, 727
  • [37] Field Evaluation of Low-Cost Particulate Matter Sensors in Beijing
    Mei, Han
    Han, Pengfei
    Wang, Yinan
    Zeng, Ning
    Liu, Di
    Cai, Qixiang
    Deng, Zhaoze
    Wang, Yinghong
    Pan, Yuepeng
    Tang, Xiao
    SENSORS, 2020, 20 (16) : 1 - 17
  • [38] Investigating the Sources of Urban Air Pollution Using Low-Cost Air Quality Sensors at an Urban Atlanta Site
    Yang, Laura Hyesung
    Hagan, David H.
    Rivera-Rios, Jean C.
    Kelp, Makoto M.
    Cross, Eben S.
    Peng, Yuyang
    Kaiser, Jennifer
    Williams, Leah R.
    Croteau, Philip L.
    Jayne, John T.
    Ng, Nga Lee
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2022, 56 (11) : 7063 - 7073
  • [39] Calibrating Low-Cost Air Quality Sensors Using Multiple Arrays of Sensors
    Barcelo-Ordinas, Jose M.
    Garcia-Vidal, Jorge
    Doudou, Messaoud
    Rodrigo-Munoz, Santiago
    Cerezo-Llavero, Albert
    2018 IEEE WIRELESS COMMUNICATIONS AND NETWORKING CONFERENCE (WCNC), 2018,
  • [40] Developing a Cloud-Based Air Quality Monitoring Platform Using Low-Cost Sensors
    Samad, Abdul
    Kieser, Joschka
    Chourdakis, Ioannis
    Vogt, Ulrich
    SENSORS, 2024, 24 (03)