90Sr bioassay in small-volume urine by ICP-MS/MS with CO2 as the reaction gas

被引:2
|
作者
Yang, Guosheng [1 ]
Tazoe, Hirofumi [2 ]
Kim, Eunjoo [1 ]
Zheng, Jian [1 ]
Kowatari, Munehiko [1 ]
Kurihara, Osamu [1 ]
机构
[1] Natl Inst Quantum Sci & Technol QST, 4-9-1 Anagawa, Inage, Chiba 2638555, Japan
[2] Hirosaki Univ, Inst Radiat Emergency Med, Aomori 0368564, Japan
基金
日本学术振兴会;
关键词
MASS; STRONTIUM; SAMPLES; I-131; MS;
D O I
10.1039/d3ja00303e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
It is critical to perform dose assessment after internal contamination with beta-particle emitting Sr-90 due to its relatively long physical and biological half-lives, along with the higher specific activities of Sr-90 and its daughter Y-90. For rapid public screening after a large-scale radiological/nuclear accident, we developed a novel Sr-90 bioassay for small-volume urine samples using triple-quadrupole inductively coupled plasma-mass spectrometry (ICP-MS/MS). After organic matter decomposition of 10 mL urine using HNO3, stacked DGA and Sr resin cartridges were used directly for chromatographic separation and purification of Sr. Yields of Sr were measured as 94 +/- 5% (n = 12) for the whole procedure, using stable Sr-88 originally in the urine sample as a yield tracer. CO2 proved to be a better reaction gas than O-2, to overcome isobaric/polyatomic interferences, especially those caused by Zr and Ge. With a conventional introduction system + s lens + 75% CO2 flow rate in the 4(#) cell gas line, the method detection limit (MDL) was estimated to be 0.978 pg L-1 (5 Bq L-1) in 10 mL urine, meeting the public screening requirement for judging ingestion/inhalation exposure beyond 1 mSv Committed Effective Dose Equivalent, with a reasonable throughput (similar to 6 h for 12 samples). For method validation, the standard reference materials provided by PROCORAD (Association for the PROmotion of Quality COntrol in RADiotoxicological Analysis), France, were analyzed and the results were all in good agreement with the assigned values.
引用
收藏
页码:2562 / 2570
页数:10
相关论文
共 50 条
  • [41] Universal isotope dilution analysis of arsenic with labelled methane gas by dynamic reaction cell ICP-MS
    Narukawa, T.
    Shikino, O.
    Chiba, K.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2020, 35 (08) : 1547 - 1551
  • [42] Automated separation, preconcentration and measurement of 90Sr in liquid samples with complex matrices by online ion exchange chromatography coupled with inductively coupled plasma mass spectrometry (ICP-MS)
    Wang, Wei
    Evans, R. Douglas
    Newman, Karla
    Khokhar, Rashid
    Wang, Wei (weiwang@trentu.ca), 1600, Elsevier B.V. (222):
  • [43] Interference-free determination of ultra-trace concentrations of arsenic and selenium using methyl fluoride as a reaction gas in ICP-MS/MS
    Bolea-Fernandez, Eduardo
    Balcaen, Lieve
    Resano, Martin
    Vanhaecke, Frank
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (03) : 919 - 929
  • [44] Low volume solution ICP-MS: achieving high-precision geochemical analysis of small amounts of sample
    Banks, Lewis A.
    Tapster, Simon R.
    Horstwood, Matthew S. A.
    Chenery, Simon R.
    Smith, Daniel J.
    Barry, Tiffany L.
    LIFE WITH ORE DEPOSITS ON EARTH, PROCEEDINGS OF THE 15TH SGA BIENNIAL MEETING, 2019, VOLS 1-4, 2019, : 1356 - 1358
  • [45] "Understanding reactions with O2 for 90Sr measurements by ICP-MS with collision reaction cell" by Favre et al. [Int. J. Mass Spectrom. 265 (2007) 15-22]
    Schofield, Keith
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2010, 289 (2-3) : 177 - 177
  • [46] Eliminating Mo isobaric interference using O2 as reaction gas for Tc measurement by triple quadrupole ICP-MS
    Bu, Wenting
    Yang, Liang
    Tang, Lei
    Xiong, Ke
    Ni, Youyi
    Yang, Chuting
    Hu, Sheng
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (06) : 1174 - 1178
  • [47] Applications of hydrogen as a collision and reaction cell gas for enhanced measurement capability applied to low level stable and radioactive isotope detection using ICP-MS/MS
    Russell, B.
    Goddard, S. L.
    Mohamud, H.
    Pearson, O.
    Zhang, Y.
    Thompkins, H.
    Brown, R. J. C.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2021, 36 (12) : 2704 - 2714
  • [48] Multielemental determination in oil matrices diluted in xylene by ICP-MS with a dynamic reaction cell employing methane as reaction gas for solving specific interferences
    de Souza, Jefferson R.
    Duyck, Christiane B.
    Fonseca, Teresa C. O.
    Saint'Pierre, Tatiana D.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2012, 27 (08) : 1280 - 1286
  • [49] Small-volume baddeleyite (ZrO2) U-Pb geochronology and Lu-Hf isotope geochemistry by LA-ICP-MS. Techniques and applications
    Ibanez-Mejia, Mauricio
    Gehrels, George E.
    Ruiz, Joaquin
    Vervoort, Jeffrey D.
    Eddy, Michael P.
    Li, Chen
    CHEMICAL GEOLOGY, 2014, 384 : 149 - 167
  • [50] Determination of aluminum in large volume parenteral drug products used in total parenteral nutrition therapy by ICP-MS with a dynamic reaction cell
    Harigaya, Koki
    Kuwahara, Yukari
    Nishi, Hiroyuki
    CHEMICAL & PHARMACEUTICAL BULLETIN, 2008, 56 (04) : 475 - 479