90Sr bioassay in small-volume urine by ICP-MS/MS with CO2 as the reaction gas

被引:2
|
作者
Yang, Guosheng [1 ]
Tazoe, Hirofumi [2 ]
Kim, Eunjoo [1 ]
Zheng, Jian [1 ]
Kowatari, Munehiko [1 ]
Kurihara, Osamu [1 ]
机构
[1] Natl Inst Quantum Sci & Technol QST, 4-9-1 Anagawa, Inage, Chiba 2638555, Japan
[2] Hirosaki Univ, Inst Radiat Emergency Med, Aomori 0368564, Japan
基金
日本学术振兴会;
关键词
MASS; STRONTIUM; SAMPLES; I-131; MS;
D O I
10.1039/d3ja00303e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
It is critical to perform dose assessment after internal contamination with beta-particle emitting Sr-90 due to its relatively long physical and biological half-lives, along with the higher specific activities of Sr-90 and its daughter Y-90. For rapid public screening after a large-scale radiological/nuclear accident, we developed a novel Sr-90 bioassay for small-volume urine samples using triple-quadrupole inductively coupled plasma-mass spectrometry (ICP-MS/MS). After organic matter decomposition of 10 mL urine using HNO3, stacked DGA and Sr resin cartridges were used directly for chromatographic separation and purification of Sr. Yields of Sr were measured as 94 +/- 5% (n = 12) for the whole procedure, using stable Sr-88 originally in the urine sample as a yield tracer. CO2 proved to be a better reaction gas than O-2, to overcome isobaric/polyatomic interferences, especially those caused by Zr and Ge. With a conventional introduction system + s lens + 75% CO2 flow rate in the 4(#) cell gas line, the method detection limit (MDL) was estimated to be 0.978 pg L-1 (5 Bq L-1) in 10 mL urine, meeting the public screening requirement for judging ingestion/inhalation exposure beyond 1 mSv Committed Effective Dose Equivalent, with a reasonable throughput (similar to 6 h for 12 samples). For method validation, the standard reference materials provided by PROCORAD (Association for the PROmotion of Quality COntrol in RADiotoxicological Analysis), France, were analyzed and the results were all in good agreement with the assigned values.
引用
收藏
页码:2562 / 2570
页数:10
相关论文
共 50 条
  • [31] Determination of Low Levels of Chromium in Biological Samples by ICP-MS Using Hydrogen as a Reaction Gas
    Connor, Ed
    Ryan, Andrew
    Riss, Peio
    SPECTROSCOPY, 2017, 32 (01) : 40 - +
  • [32] Determination of 90Sr in soil samples using inductively coupled plasma mass spectrometry equipped with dynamic reaction cell (ICP-DRC-MS)
    Feuerstein, J.
    Boulyga, S. F.
    Galler, P.
    Stingeder, G.
    Prohaska, T.
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2008, 99 (11) : 1764 - 1769
  • [33] Sensitivity enhancement in laser ablation ICP-MS using small amounts of hydrogen in the carrier gas
    Guillong, Marcel
    Heinrich, Christoph A.
    Journal of Analytical Atomic Spectrometry, 2007, 22 (12): : 1488 - 1494
  • [34] Cascade signal amplification using Hg2+-induced oxidation of silver nanoparticles and cation exchange reaction for ICP-MS bioassay
    He, Yujing
    Hu, Jing
    Tian, Yunfei
    Hou, Xiandeng
    CHEMICAL COMMUNICATIONS, 2023, 59 (99) : 14677 - 14680
  • [35] Sensitivity enhancement in laser ablation ICP-MS using small amounts of hydrogen in the carrier gas
    Guillong, Marcel
    Heinrich, Christoph A.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2007, 22 (12) : 1488 - 1494
  • [36] The screening of intermediates in a ruthenium and iridium ion-catalyzed gas-phase reaction of ethanol converting to butanol by ICP-MS/MS
    Zhu, Xuewei
    He, Qian
    Xu, Fujian
    Ma, Xiaoxiao
    Xing, Zhi
    Zhang, Sichun
    Zhang, Xinrong
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2020, 35 (04) : 804 - 809
  • [37] ICP-MS Assisted EDX Tomography: A Robust Method for Studying Electrolyte Penetration Phenomena in Gas Diffusion Electrodes Applied to CO2 Electrolysis
    Rieder, Alain
    Lorenzetti, Julia
    Montiel, Ivan Zelocualtecatl
    Dutta, Abhijit
    Iarchuk, Anna
    Mirolo, Marta
    Drnec, Jakub
    Lorenzutti, Francesca
    Haussener, Sophia
    Kovacs, Noemi
    Vesztergom, Soma
    Broekmann, Peter
    SMALL METHODS, 2024,
  • [39] INFRARED GAS-ANALYSIS OF BOTH GASEOUS AND DISSOLVED CO2 IN SMALL-VOLUME MARINE SAMPLES
    ROBERTS, DG
    SMITH, DM
    LIMNOLOGY AND OCEANOGRAPHY, 1988, 33 (01) : 135 - 140
  • [40] Automated separation, preconcentration and measurement of 90Sr in liquid samples with complex matrices by online ion exchange chromatography coupled with inductively coupled plasma mass spectrometry (ICP-MS)
    Wang, Wei
    Evans, R. Douglas
    Newman, Karla
    Khokhar, Rashid
    TALANTA, 2021, 222