90Sr bioassay in small-volume urine by ICP-MS/MS with CO2 as the reaction gas

被引:2
|
作者
Yang, Guosheng [1 ]
Tazoe, Hirofumi [2 ]
Kim, Eunjoo [1 ]
Zheng, Jian [1 ]
Kowatari, Munehiko [1 ]
Kurihara, Osamu [1 ]
机构
[1] Natl Inst Quantum Sci & Technol QST, 4-9-1 Anagawa, Inage, Chiba 2638555, Japan
[2] Hirosaki Univ, Inst Radiat Emergency Med, Aomori 0368564, Japan
基金
日本学术振兴会;
关键词
MASS; STRONTIUM; SAMPLES; I-131; MS;
D O I
10.1039/d3ja00303e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
It is critical to perform dose assessment after internal contamination with beta-particle emitting Sr-90 due to its relatively long physical and biological half-lives, along with the higher specific activities of Sr-90 and its daughter Y-90. For rapid public screening after a large-scale radiological/nuclear accident, we developed a novel Sr-90 bioassay for small-volume urine samples using triple-quadrupole inductively coupled plasma-mass spectrometry (ICP-MS/MS). After organic matter decomposition of 10 mL urine using HNO3, stacked DGA and Sr resin cartridges were used directly for chromatographic separation and purification of Sr. Yields of Sr were measured as 94 +/- 5% (n = 12) for the whole procedure, using stable Sr-88 originally in the urine sample as a yield tracer. CO2 proved to be a better reaction gas than O-2, to overcome isobaric/polyatomic interferences, especially those caused by Zr and Ge. With a conventional introduction system + s lens + 75% CO2 flow rate in the 4(#) cell gas line, the method detection limit (MDL) was estimated to be 0.978 pg L-1 (5 Bq L-1) in 10 mL urine, meeting the public screening requirement for judging ingestion/inhalation exposure beyond 1 mSv Committed Effective Dose Equivalent, with a reasonable throughput (similar to 6 h for 12 samples). For method validation, the standard reference materials provided by PROCORAD (Association for the PROmotion of Quality COntrol in RADiotoxicological Analysis), France, were analyzed and the results were all in good agreement with the assigned values.
引用
收藏
页码:2562 / 2570
页数:10
相关论文
共 50 条
  • [1] Determination of 90Sr at ultratrace levels in urine by ICP-MS
    Vonderheide, Anne P.
    Zoriy, Myroslav V.
    Izmer, Andrei V.
    Pickhardt, Carola
    Caruso, Joseph A.
    Ostapczuk, Peter
    Hille, Ralf
    Becker, J. Sabine
    Journal of Analytical Atomic Spectrometry, 2004, 19 (05): : 675 - 680
  • [2] Determination of 90Sr at ultratrace levels in urine by ICP-MS
    Vonderheide, AP
    Zoriy, MV
    Izmer, AV
    Pickhardt, C
    Caruso, JA
    Ostapczuk, P
    Hille, R
    Becker, JS
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (05) : 675 - 680
  • [3] Understanding reactions with O2 for 90Sr measurements by ICP-MS with collision-reaction cell
    Favre, Georges
    Brennetot, Rene
    Chartier, Frederic
    Vitorge, Pierre
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2007, 265 (01) : 15 - 22
  • [4] TIMS vs. ICP-MS measurements for age dating 90Sr
    Steeb, Jennifer L.
    Graczyk, Donald G.
    Mertz, Carol J.
    Essling, Alice M.
    Tsai, Yifen
    Chamberlain, David B.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2013, 245
  • [5] Determination of 90Sr in contaminated environmental samples by tuneable bandpass dynamic reaction cell ICP-MS
    Taylor, V. F.
    Evans, R. D.
    Cornett, R. J.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 387 (01) : 343 - 350
  • [6] Rapid analysis of 237Np and Pu isotopes in small volume urine by SF- ICP-MS and ICP-MS/MS
    Yang, Guosheng
    Zheng, Jian
    Kim, Eunjoo
    Zhang, Shuai
    Seno, Hatsuho
    Kowatari, Munehiko
    Aono, Tatsuo
    Kurihara, Osamu
    ANALYTICA CHIMICA ACTA, 2021, 1158
  • [7] Determination of 90Sr in large mass of apples and cabbages by triple quadruple collision/reaction cell ICP-MS
    Zhong, Ningjie
    Zhao, Xinghong
    Li, Lili
    Xu, Changkun
    Huang, Shenghui
    Zhao, Lifei
    Zhao, Yonggang
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2025, 334 (01) : 131 - 140
  • [8] Gas-Phase Ion-Molecule Interactions in a Collision Reaction Cell with ICP-MS/MS: Investigations with CO2 as the Reaction Gas
    Harouaka, Khadouja
    Melby, Kali
    Bylaska, Eric J.
    Cox, Richard M.
    Eiden, Gregory C.
    French, Amanda
    Hoppe, Eric W.
    Arnquist, Isaac J.
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2022, 46 (03) : 387 - 399
  • [9] Understanding reactions with O2 for 90Sr measurements by ICP-MS with collision reaction cell (vol 289, pg 177, 2010)
    Brennetot, Rene
    Vitorge, Pierre
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2010, 293 (1-3) : 56 - 56
  • [10] Determination of natural Sr and 90Sr in environmental samples by ETV-ICP-MS
    Institute for National Measurements Standards, National Research Council Canada, Ottawa, Ont. K1A 0R6, Canada
    J Anal At Spectrom, 2007, 11 (1409-1414):