High-flow via a tracheostomy tube and speaking valve during weaning from mechanical ventilation and tracheostomy

被引:2
|
作者
Egbers, Peter H. H. [1 ]
Sutt, Anna-Liisa [2 ,3 ,4 ]
Petersson, Jenny E. E. [5 ,6 ]
Bergstrom, Liza [5 ,7 ]
Sundman, Eva [5 ,6 ,8 ]
机构
[1] Med Ctr Leeuwarden, Leeuwarden, Netherlands
[2] Prince Charles Hosp, Crit Care Res Grp, Brisbane, Qld, Australia
[3] Univ Queensland, Sch Med, Brisbane, Qld, Australia
[4] Royal London Hosp, Bank Partners, London, England
[5] Remeo Intens Care Rehabil Ctr, Stockholm, Sweden
[6] Karolinska Inst, Dept Med Solna, Stockholm, Sweden
[7] Danderyd Hosp, Karolinska Inst, Dept Clin Sci, Div Neurol, Stockholm, Sweden
[8] Thorsten Levenstamsvag 4, S-12864 Skondal, Sweden
关键词
active humidification; cannula; chronic critical illness; critical care; decannulation; intensive care rehabilitation; laryngeal and pharyngeal rehabilitation; persistent critical illness; prolonged mechanical ventilation; speech; tracheostomy; CARE; SPEECH; OXYGEN;
D O I
10.1111/aas.14305
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Weaning from mechanical ventilation and tracheostomy after prolonged intensive care consume enormous resources with optimal management not currently well described. Restoration of respiratory flow via the upper airway is essential and early cuff-deflation using a one-way valve (OWV) is recommended. However, extended OWV use may cause dry airways and thickened secretions which challenge the weaning process. High-flow therapy via the tracheostomy tube (HFT-T) humidifies inspired air and may be connected via an in-line OWV (HFT-T-OWV) alleviating these problems. We aim to provide clinical and experimental data on the safety of HFT-T-OWV along with a practical guide to facilitate clinical use during weaning from mechanical ventilation and tracheostomy.Methods: Data on adverse events of HFT-T-OWV were retrieved from a quality register for patients treated at an intensive care rehabilitation center between 2019 and 2022. Benchtop experiments were performed to measure maximum pressures and pressure support generated by HFT-T-OWV at 25-60 L/min flow using two different HFT-T adapters (interfaces). In simulated airway obstruction using a standard OWV (not in-line) maximum pressures were measured with oxygen delivered via the side port at 1-3 L/min.Results: Of 128 tracheostomized patients who underwent weaning attempts, 124 were treated with HFT-T-OWV. The therapy was well tolerated, and no adverse events related to the practice were detected. The main reason for not using HFT-T-OWV was partial upper airway obstruction using a OWV. Benchtop experiments demonstrated HFT-T-OWV maximum pressures <4 cmH(2)O and pressure support 0-0.6 cmH(2)O. In contrast, 1-3 L/min supplemental oxygen via a standard OWV caused pressures between 84 and 148 cmH(2)O during simulated airway obstruction.Conclusions: Current study clinical data and benchtop experiments indicate that HFT-T-OWV was well tolerated and appeared safe. Pressure support was low, but humidification may enable extended use of a OWV without dry airway mucosa and thickened secretions. Results suggest the treatment could offer advantages to standard OWV use, with or without supplementary oxygen, as well as to HFT-T without a OWV, for weaning from mechanical ventilation and tracheostomy. However, for definitive treatment recommendations, randomized clinical trials are needed.
引用
收藏
页码:1403 / 1413
页数:11
相关论文
共 50 条
  • [31] Influence of endotracheal tube guides on ventilation parameters during percutaneous tracheostomy
    Croitoru, M.
    Dor, I.
    Krimerman, S.
    Sabo, E.
    Altman, E.
    Teitelman, U.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2004, 21 : 70 - 70
  • [32] Sequential invasive-noninvasive mechanical ventilation weaning strategy for patients after tracheostomy
    Xue-xue Pu
    Jiong Wang
    Xue-bo Yan
    Xue-qin Jiang
    World Journal of Emergency Medicine, 2015, (03) : 196 - 200
  • [33] Additional Expiratory Resistance Elevates Airway Pressure and Lung Volume during High-Flow Tracheal Oxygen via Tracheostomy
    Guang-Qiang Chen
    Xiu-Mei Sun
    Yu-Mei Wang
    Yi-Min Zhou
    Jing-Ran Chen
    Kun-Ming Cheng
    Yan-Lin Yang
    Jian-Xin Zhou
    Scientific Reports, 9
  • [34] Additional Expiratory Resistance Elevates Airway Pressure and Lung Volume during High-Flow Tracheal Oxygen via Tracheostomy
    Chen, Guang-Qiang
    Sun, Xiu-Mei
    Wang, Yu-Mei
    Zhou, Yi-Min
    Chen, Jing-Ran
    Cheng, Kun-Ming
    Yang, Yan-Lin
    Zhou, Jian-Xin
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [35] PATIENT OUTCOME FOLLOWING PROLONGED MECHANICAL VENTILATION (MV) VIA TRACHEOSTOMY
    CRINER, GJ
    KREIMER, DT
    PIDLAOAN, L
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1993, 147 (04): : A874 - A874
  • [36] The safety of tracheostomy speaking valve use during sleep in children: A pilot study
    Barraza, Giselle Y.
    Fernandez, Claudia
    Halaby, Claudia
    Ambrosio, Sara
    Simpser, Edwin F.
    Pirzada, Melodi B.
    AMERICAN JOURNAL OF OTOLARYNGOLOGY, 2014, 35 (05) : 636 - 640
  • [37] Single-lung ventilation via a double lumen tube in a patient with a tracheostomy
    Renton, MC
    Conacher, ID
    ANAESTHESIA, 2002, 57 (02) : 197 - 198
  • [38] One-Lung Ventilation Via Tracheostomy and Left Endobronchial Microlaryngeal Tube
    Howell, Stephen
    Ata, Monica
    Ellison, Matthew
    Wilson, Colin
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2014, 28 (04) : 1040 - 1042
  • [39] Catheter mount used as tracheostomy interface in high-flow oxygen therapy
    Kodamanchili, Saiteja
    Priyanka, Tn
    Anand, Abhijeet
    Panda, Rajesh
    JOURNAL OF ANAESTHESIOLOGY CLINICAL PHARMACOLOGY, 2024, 40 (01) : 168 - 169
  • [40] Tracheostomy tube occlusion protocol predicts significant tracheal obstruction to air flow in patients requiring prolonged mechanical ventilation
    Rumbak, MJ
    Graves, AE
    Scott, MP
    Sporn, GK
    Walsh, FW
    Anderson, WM
    Goldman, AL
    CRITICAL CARE MEDICINE, 1997, 25 (03) : 413 - 417