High-flow via a tracheostomy tube and speaking valve during weaning from mechanical ventilation and tracheostomy

被引:2
|
作者
Egbers, Peter H. H. [1 ]
Sutt, Anna-Liisa [2 ,3 ,4 ]
Petersson, Jenny E. E. [5 ,6 ]
Bergstrom, Liza [5 ,7 ]
Sundman, Eva [5 ,6 ,8 ]
机构
[1] Med Ctr Leeuwarden, Leeuwarden, Netherlands
[2] Prince Charles Hosp, Crit Care Res Grp, Brisbane, Qld, Australia
[3] Univ Queensland, Sch Med, Brisbane, Qld, Australia
[4] Royal London Hosp, Bank Partners, London, England
[5] Remeo Intens Care Rehabil Ctr, Stockholm, Sweden
[6] Karolinska Inst, Dept Med Solna, Stockholm, Sweden
[7] Danderyd Hosp, Karolinska Inst, Dept Clin Sci, Div Neurol, Stockholm, Sweden
[8] Thorsten Levenstamsvag 4, S-12864 Skondal, Sweden
关键词
active humidification; cannula; chronic critical illness; critical care; decannulation; intensive care rehabilitation; laryngeal and pharyngeal rehabilitation; persistent critical illness; prolonged mechanical ventilation; speech; tracheostomy; CARE; SPEECH; OXYGEN;
D O I
10.1111/aas.14305
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Weaning from mechanical ventilation and tracheostomy after prolonged intensive care consume enormous resources with optimal management not currently well described. Restoration of respiratory flow via the upper airway is essential and early cuff-deflation using a one-way valve (OWV) is recommended. However, extended OWV use may cause dry airways and thickened secretions which challenge the weaning process. High-flow therapy via the tracheostomy tube (HFT-T) humidifies inspired air and may be connected via an in-line OWV (HFT-T-OWV) alleviating these problems. We aim to provide clinical and experimental data on the safety of HFT-T-OWV along with a practical guide to facilitate clinical use during weaning from mechanical ventilation and tracheostomy.Methods: Data on adverse events of HFT-T-OWV were retrieved from a quality register for patients treated at an intensive care rehabilitation center between 2019 and 2022. Benchtop experiments were performed to measure maximum pressures and pressure support generated by HFT-T-OWV at 25-60 L/min flow using two different HFT-T adapters (interfaces). In simulated airway obstruction using a standard OWV (not in-line) maximum pressures were measured with oxygen delivered via the side port at 1-3 L/min.Results: Of 128 tracheostomized patients who underwent weaning attempts, 124 were treated with HFT-T-OWV. The therapy was well tolerated, and no adverse events related to the practice were detected. The main reason for not using HFT-T-OWV was partial upper airway obstruction using a OWV. Benchtop experiments demonstrated HFT-T-OWV maximum pressures <4 cmH(2)O and pressure support 0-0.6 cmH(2)O. In contrast, 1-3 L/min supplemental oxygen via a standard OWV caused pressures between 84 and 148 cmH(2)O during simulated airway obstruction.Conclusions: Current study clinical data and benchtop experiments indicate that HFT-T-OWV was well tolerated and appeared safe. Pressure support was low, but humidification may enable extended use of a OWV without dry airway mucosa and thickened secretions. Results suggest the treatment could offer advantages to standard OWV use, with or without supplementary oxygen, as well as to HFT-T without a OWV, for weaning from mechanical ventilation and tracheostomy. However, for definitive treatment recommendations, randomized clinical trials are needed.
引用
收藏
页码:1403 / 1413
页数:11
相关论文
共 50 条
  • [21] High-Flow Oxygen with Capping or Suctioning for Tracheostomy Decannulation
    Martinez, Gonzalo Hernandez
    Rodriguez, Maria-Luisa
    Vaquero, Maria-Concepcion
    Ortiz, Ramon
    Masclans, Joan-Ramon
    Roca, Oriol
    Colinas, Laura
    de Pablo, Raul
    Espinosa, Maria-del-Carmen
    Garcia-de-Acilu, Marina
    Climent, Cristina
    Cuena-Boy, Rafael
    NEW ENGLAND JOURNAL OF MEDICINE, 2020, 383 (11): : 1009 - 1017
  • [22] High-flow Oxygen Therapy via Tracheostomy to liberate COVID-19-induced. ARDS from Invasive Ventilation: A Case Series
    Vadi, Sonali
    Phadtare, Sourabh
    Shetty, Kiran
    INDIAN JOURNAL OF CRITICAL CARE MEDICINE, 2021, 25 (06) : 723 - 727
  • [23] Airway fire during awake tracheostomy using high-flow nasal oxygen
    Adams, T. R. P.
    Ricciardelli, A.
    ANAESTHESIA REPORTS, 2020, 8 (01) : 25 - 27
  • [24] Tracheostomy improves lung mechanics and weaning success rate for prolonged mechanical ventilation
    Lee, DL
    Chang, YW
    Chang, HT
    INTENSIVE CARE MEDICINE, 2001, 27 : S213 - S213
  • [25] Mechanical Positive Pressure Ventilation and Voice Training via the Blom? Tracheostomy Tube: A Case Study
    Takei, Tomohide
    Kida, Tatsuya
    Usuda, Yutaka
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (03)
  • [26] HIGH-FLOW OXYGEN THERAPY TO SPEED WEANING FROM MECHANICAL VENTILATION: A PROSPECTIVE RANDOMIZED STUDY
    Liu, Fen
    Shao, Qiang
    Jiang, Rong
    Zeng, Zhenguo
    Liu, Yang
    Li, Yong
    Liu, Qin
    Ding, Chengzhi
    Zhao, Ning
    Peng, Zhiyong
    Qian, Kejian
    AMERICAN JOURNAL OF CRITICAL CARE, 2019, 28 (05) : 370 - 376
  • [27] Physiological Effects of High-Flow Tracheal Oxygen in Tracheostomized Patients Weaning From Mechanical Ventilation
    Janssen, Matthijs L.
    Weller, Dolf
    Endeman, Henrik
    Heunks, Leo M. A.
    Wils, Evert-Jan
    RESPIRATORY CARE, 2024, 69 (10) : 1336 - 1344
  • [28] Maintaining oxygenation with high-flow nasal cannula during emergent awake surgical tracheostomy
    Ffrench-O'Carroll, R.
    Fitzpatrick, K.
    Jonker, W. R.
    Choo, M.
    Tujjar, O.
    BRITISH JOURNAL OF ANAESTHESIA, 2017, 118 (06) : 954 - 955
  • [29] Sequential invasive-noninvasive mechanical ventilation weaning strategy for patients after tracheostomy
    Xue-xue Pu
    Jiong Wang
    Xue-bo Yan
    Xue-qin Jiang
    World Journal of Emergency Medicine, 2015, 6 (03) : 196 - 200
  • [30] Sequential invasive-noninvasive mechanical ventilation weaning strategy for patients after tracheostomy
    Pu, Xue-xue
    Wang, Jiong
    Yan, Xue-bo
    Jiang, Xue-qin
    WORLD JOURNAL OF EMERGENCY MEDICINE, 2015, 6 (03): : 196 - 200