Feasibility and accuracy of coronary artery calcium score on virtual non-contrast images derived from a dual-layer spectral detector CT: A retrospective multicenter study

被引:4
|
作者
Yang, Panpan [1 ,2 ]
Zhao, Ren [3 ]
Deng, Wei [1 ,2 ]
An, Shutian [1 ,2 ]
Li, Yuguo [1 ,2 ]
Sheng, Mao [4 ]
Chen, Xingbiao [5 ]
Qian, Yingfeng [1 ,2 ]
Yu, Yongqiang [1 ,2 ]
Mu, Dan [6 ]
Wang, Yining [7 ]
Li, Xiaohu [1 ,2 ]
机构
[1] Anhui Med Univ, Affiliated Hosp 1, Dept Radiol, Hefei, Anhui, Peoples R China
[2] Anhui Prov Clin Image Qual Control Ctr, Res Ctr Clin Med Imaging, Hefei, Anhui, Peoples R China
[3] Anhui Med Univ, Affiliated Hosp 1, Dept Cardiol, Hefei, Anhui, Peoples R China
[4] Anhui Med Univ, Peoples Hosp Hefei 2, Hefei Hosp, Dept Radiol, Hefei, Anhui, Peoples R China
[5] Philips Healthcare, Clin Sci, Shanghai, Peoples R China
[6] Nanjing Univ, Dept Radiol, Affiliated Nanjing Drum Tower Hosp, Med Sch, Nanjing, Peoples R China
[7] Peking Union Med Coll Hosp, Dept Radiol, Beijing, Peoples R China
来源
基金
美国国家科学基金会; 中国国家自然科学基金;
关键词
coronary artery calcium score; coronary artery disease; computed tomography angiography; dual energy CT (DECT); dual energy CT system; QUANTIFICATION;
D O I
10.3389/fcvm.2023.1114058
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Rationale and objectiveThis retrospective study was to evaluate the feasibility and accuracy of coronary artery calcium score (CACS) from virtual non-contrast (VNC) images in comparison with that from true non-contrast (TNC) images. Materials and methodsA total of 540 patients with suspected of coronary artery disease (CAD) who underwent a dual-layer spectral detector CT (SDCT) in three hospitals were eligible for this study and 233 patients were retrospectively enrolled for further analysis. The CACS was calculated from both TNC and VNC images and compared. Linear regression analysis of the CACS was performed between TNC and VNC images. ResultsThe correlation of overall CACS from VNC and TNC images was very strong (r = 0.923, p < 0.001). The CACS from VNC images were lower than that from TNC images (221 versus. 69, p < 0.001). When the regression equation of the overall coronary artery was applied, the mean calibrated CACS-VNC was 221 which had a significant difference from the CACS-TNC (p = 0.017). When the regression equation of each coronary branch artery was applied, the mean calibrated CACS-VNC was 221, which had a significant difference from the CACS-TNC (p = 0.003). But the mean difference between the CACS-TNC and the calibrated CACS-VNC in either way was less than 1. The agreement on risk stratification with CACS-TNC and CCACS-VNC was almost perfect. ConclusionThis multicenter study with dual-layer spectral detector CT showed that it was feasible to calculate CACS from the VNC images derived from the spectral coronary artery CT angiography scan, and the results were in good accordance with the TNC images after correction. Therefore, the TNC scan could be omitted, reducing the radiation dose to patients and saving examination time while using dual-layer spectral detector CT.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Feasibility of low-dose contrast media in run-off CT angiography on dual-layer spectral detector CT
    Ren, Haiyan
    Zhen, Yanhua
    Gong, Zheng
    Wang, Chuanzhuo
    Chang, Zhihui
    Zheng, Jiahe
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2021, 11 (05) : 1796 - 1804
  • [42] Virtual versus true non-contrast images of the brain from spectral detector CT: comparison of attenuation values and image quality
    Kessner, Rivka
    Sommer, Jennifer
    Hokamp, Nils Grosse
    Laukamp, Kai R.
    Nayate, Ameya
    ACTA RADIOLOGICA, 2023, 64 (02) : 776 - 783
  • [43] Dual-Energy CT in the Assessment of Mediastinal Lymph Nodes: Comparative Study of Virtual Non-Contrast and True Non-Contrast Images
    Yoo, Seon Young
    Kim, Yookyung
    Cho, Hyun Hae
    Choi, Mi Joo
    Shim, Sung Shine
    Lee, Jeong Kyong
    Baek, Seung Yon
    KOREAN JOURNAL OF RADIOLOGY, 2013, 14 (03) : 532 - 539
  • [44] Evaluation of virtual non-contrast detector-based spectral CT images in comparison to true unenhanced images in 20 rabbits
    Mikic, Manon
    Lietz, Philipp
    Dierig, Julie-Ann
    Meller, Sebastian
    Pees, Michael
    Merhof, Kristina
    FRONTIERS IN VETERINARY SCIENCE, 2025, 12
  • [45] Accuracy of bone mineral density quantification using dual-layer spectral detector CT: a phantom study
    van Hamersvelt, Robbert W.
    Schilham, Arnold M. R.
    Engelke, Klaus
    den Harder, Annemarie M.
    de Keizer, Bart
    Verhaar, Harald J.
    Leiner, Tim
    de Jong, Pim A.
    Willemink, Martin J.
    EUROPEAN RADIOLOGY, 2017, 27 (10) : 4351 - 4359
  • [46] Accuracy of bone mineral density quantification using dual-layer spectral detector CT: a phantom study
    Robbert W. van Hamersvelt
    Arnold M. R. Schilham
    Klaus Engelke
    Annemarie M. den Harder
    Bart de Keizer
    Harald J. Verhaar
    Tim Leiner
    Pim A. de Jong
    Martin J. Willemink
    European Radiology, 2017, 27 : 4351 - 4359
  • [47] Comparison of true non- contrast and virtual non-contrast images in the characterization of renal lesions using detector- based spectral CT
    Verstraeten, Sabine
    Ansems, Janneke
    Van Ommen, Wenzel
    Van Der Linden, Diana
    Looijmans, Frank
    Tesselaar, Erik
    BRITISH JOURNAL OF RADIOLOGY, 2023, 96 (1149):
  • [48] Utilization of virtual non-contrast images derived from dual-energy CT in evaluation of biliary stone disease: Virtual non-contrast image can replace true non-contrast image regarding biliary stone detection
    Bae, Jae Seok
    Lee, Dong Ho
    Joo, Ijin
    Jeon, Sun Kyung
    Han, Joon Koo
    EUROPEAN JOURNAL OF RADIOLOGY, 2019, 116 : 34 - 40
  • [49] Association of Pericoronary Adipose Tissue Quality Determined by Dual-Layer Spectral Detector CT With Severity of Coronary Artery Disease: A Preliminary Study
    Dang, Yuxue
    Chen, Xujiao
    Ma, Shaowei
    Ma, Yue
    Ma, Quanmei
    Zhou, Ke
    Liu, Ting
    Wang, Kunhua
    Hou, Yang
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2021, 8
  • [50] Dual-energy CT angiography-derived virtual non-contrast images for follow-up of patients with surgically clipped aneurysms: a retrospective study
    Su Young Yun
    Young Jin Heo
    Hae Woong Jeong
    Jin Wook Baek
    Hye Jung Choo
    Gi Won Shin
    Sung Tae Kim
    Young Gyun Jeong
    Ji Young Lee
    Hyun Seok Jung
    Neuroradiology, 2019, 61 : 747 - 755