Feasibility and accuracy of coronary artery calcium score on virtual non-contrast images derived from a dual-layer spectral detector CT: A retrospective multicenter study

被引:4
|
作者
Yang, Panpan [1 ,2 ]
Zhao, Ren [3 ]
Deng, Wei [1 ,2 ]
An, Shutian [1 ,2 ]
Li, Yuguo [1 ,2 ]
Sheng, Mao [4 ]
Chen, Xingbiao [5 ]
Qian, Yingfeng [1 ,2 ]
Yu, Yongqiang [1 ,2 ]
Mu, Dan [6 ]
Wang, Yining [7 ]
Li, Xiaohu [1 ,2 ]
机构
[1] Anhui Med Univ, Affiliated Hosp 1, Dept Radiol, Hefei, Anhui, Peoples R China
[2] Anhui Prov Clin Image Qual Control Ctr, Res Ctr Clin Med Imaging, Hefei, Anhui, Peoples R China
[3] Anhui Med Univ, Affiliated Hosp 1, Dept Cardiol, Hefei, Anhui, Peoples R China
[4] Anhui Med Univ, Peoples Hosp Hefei 2, Hefei Hosp, Dept Radiol, Hefei, Anhui, Peoples R China
[5] Philips Healthcare, Clin Sci, Shanghai, Peoples R China
[6] Nanjing Univ, Dept Radiol, Affiliated Nanjing Drum Tower Hosp, Med Sch, Nanjing, Peoples R China
[7] Peking Union Med Coll Hosp, Dept Radiol, Beijing, Peoples R China
来源
基金
美国国家科学基金会; 中国国家自然科学基金;
关键词
coronary artery calcium score; coronary artery disease; computed tomography angiography; dual energy CT (DECT); dual energy CT system; QUANTIFICATION;
D O I
10.3389/fcvm.2023.1114058
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Rationale and objectiveThis retrospective study was to evaluate the feasibility and accuracy of coronary artery calcium score (CACS) from virtual non-contrast (VNC) images in comparison with that from true non-contrast (TNC) images. Materials and methodsA total of 540 patients with suspected of coronary artery disease (CAD) who underwent a dual-layer spectral detector CT (SDCT) in three hospitals were eligible for this study and 233 patients were retrospectively enrolled for further analysis. The CACS was calculated from both TNC and VNC images and compared. Linear regression analysis of the CACS was performed between TNC and VNC images. ResultsThe correlation of overall CACS from VNC and TNC images was very strong (r = 0.923, p < 0.001). The CACS from VNC images were lower than that from TNC images (221 versus. 69, p < 0.001). When the regression equation of the overall coronary artery was applied, the mean calibrated CACS-VNC was 221 which had a significant difference from the CACS-TNC (p = 0.017). When the regression equation of each coronary branch artery was applied, the mean calibrated CACS-VNC was 221, which had a significant difference from the CACS-TNC (p = 0.003). But the mean difference between the CACS-TNC and the calibrated CACS-VNC in either way was less than 1. The agreement on risk stratification with CACS-TNC and CCACS-VNC was almost perfect. ConclusionThis multicenter study with dual-layer spectral detector CT showed that it was feasible to calculate CACS from the VNC images derived from the spectral coronary artery CT angiography scan, and the results were in good accordance with the TNC images after correction. Therefore, the TNC scan could be omitted, reducing the radiation dose to patients and saving examination time while using dual-layer spectral detector CT.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Diagnostic value of non-contrast electron density imaging using dual-layer spectral detector CT for small gastric stromal tumors
    Qi, Liping
    Gui, Shen
    Zhong, Zhilin
    Chen, Xianfeng
    DIGESTIVE AND LIVER DISEASE, 2025, 57 (04) : 927 - 928
  • [32] Feasibility and accuracy of dual-layer spectral detector computed tomography for quantification of gadolinium: a phantom study
    Robbert W. van Hamersvelt
    Martin J. Willemink
    Pim A. de Jong
    Julien Milles
    Alain Vlassenbroek
    Arnold M. R. Schilham
    Tim Leiner
    European Radiology, 2017, 27 : 3677 - 3686
  • [33] Feasibility and accuracy of dual-layer spectral detector computed tomography for quantification of gadolinium: a phantom study
    van Hamersvelt, Robbert W.
    Willemink, Martin J.
    de Jong, Pim A.
    Milles, Julien
    Vlassenbroek, Alain
    Schilham, Arnold M. R.
    Leiner, Tim
    EUROPEAN RADIOLOGY, 2017, 27 (09) : 3677 - 3686
  • [34] Utilization of virtual mono-energetic images (MonoE) derived from a dual-layer spectral detector CT (SDCT) for the assessment of abdominal arteries in venous contrast phase scans
    Hickethier, Tilman
    Byrtus, Jonathan
    Hauger, Myriam
    Iuga, Andra-Iza
    Pahn, Gregor
    Maintz, David
    Haneder, Stefan
    Doerner, Jonas
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 99 : 28 - 33
  • [35] Dual-layer spectral CT virtual-non-contrast images aid in parathyroid adenoma analysis and radiation dose reduction: confirmation of findings from dual CT
    Maraia, Danielle
    Hemmerdinger, Steven
    Chiarolanzio, Patrick
    Mehta, Hasit
    Ali, Sana
    Gomes, William
    Schefflein, Javin
    High, Maynard
    Gulko, Edwin
    CLINICAL IMAGING, 2022, 84 : 113 - 117
  • [36] Heart rate sensitivity of virtual non-contrast calcium scores derived from photon counting detector CT data: a phantom study
    Risch, Franka
    Schwarz, Florian
    Kroencke, Thomas
    Decker, Josua A.
    RADIOLOGIA MEDICA, 2024, 129 (03): : 401 - 410
  • [37] Virtual non-contrast images from dual-energy CT angiography of the abdominal aorta and femoral arteries: comparison with true non-contrast CT images
    Lee, Min Hee
    Park, Hee Jin
    Kim, Ji Na
    Kim, Myung Sub
    Hong, Seok Woo
    Park, Jai Hyung
    Kang, Chang Ho
    BRITISH JOURNAL OF RADIOLOGY, 2022, 95 (1138):
  • [38] Virtual monochromatic images for coronary artery imaging with a spectral photon-counting CT in comparison to dual-layer CT systems: a phantom and a preliminary human study
    Joel Greffier
    Salim A. Si-Mohamed
    Hugo Lacombe
    Joey Labour
    Djamel Djabli
    Sara Boccalini
    Mohammad Varasteh
    Marjorie Villien
    Yoad Yagil
    Klaus Erhard
    Loic Boussel
    Jean-Paul Beregi
    Philippe C. Douek
    European Radiology, 2023, 33 : 5476 - 5488
  • [39] Virtual monochromatic images for coronary artery imaging with a spectral photon-counting CT in comparison to dual-layer CT systems: a phantom and a preliminary human study
    Greffier, Joel
    Si-Mohamed, Salim A.
    Lacombe, Hugo
    Labour, Joey
    Djabli, Djamel
    Boccalini, Sara
    Varasteh, Mohammad
    Villien, Marjorie
    Yagil, Yoad
    Erhard, Klaus
    Boussel, Loic
    Beregi, Jean-Paul
    Douek, Philippe C.
    EUROPEAN RADIOLOGY, 2023, 33 (08) : 5476 - 5488
  • [40] Heart rate sensitivity of virtual non-contrast calcium scores derived from photon counting detector CT data: a phantom study
    Franka Risch
    Florian Schwarz
    Thomas Kroencke
    Josua A. Decker
    La radiologia medica, 2024, 129 : 401 - 410