Monte Carlo simulation of the Varian TrueBeam flattened-filtered beams using a surrogate geometry in PRIMO

被引:1
|
作者
Rodriguez, Miguel [1 ,2 ]
Sempau, Josep [3 ,4 ,5 ]
Brualla, Lorenzo [6 ,7 ,8 ,9 ]
机构
[1] Hosp Paitilla, Calle 53 & Ave Balboa, Panama City, Panama
[2] Inst Invest Cient & Serv Alta Tecnol AIP INDICASAT, Edificio 219, Panama City, Panama
[3] Univ Politecn Cataluna, Dept Phys, Diagonal 647, Barcelona 08028, Spain
[4] Univ Politecn Cataluna, Inst Tecn Energet, Diagonal 647, Barcelona 08028, Spain
[5] Ctr Invest Biomed Red Bioingn Biomat & Nanomed CIB, Diagonal 647, Madrid 28029, Spain
[6] Westdeutsches Protonentherapiezentrum Essen WPE, Hufelandstr 55, D-45147 Essen, Germany
[7] West German Canc Ctr WTZ, Hufelandstr 55, D-45147 Essen, Germany
[8] Univ Duisburg Essen, Med Fak, IMIB, Hufelandstr 55, D-45147 Essen, Germany
[9] German Canc Consortium DKTK, Hufelandstr 55, D-45147 Essen, Germany
关键词
Monte Carlo; Phase space; PRIMO; Linear accelerator; IMPLEMENTATION; PENELOPE; PHOTON; CAD;
D O I
10.1186/s13014-024-02405-w
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background Monte Carlo simulation of radiation transport for medical linear accelerators (linacs) requires accurate knowledge of the geometrical description of the linac head. Since the geometry of Varian TrueBeam machines has not been disclosed, the manufacturer distributes phase-space files of the linac patient-independent part to allow researchers to compute absorbed dose distributions using the Monte Carlo method. This approach limits the possibility of achieving an arbitrarily small statistical uncertainty. This work investigates the use of the geometry of the Varian Clinac 2100, which is included in the Monte Carlo system PRIMO, as a surrogate. Methods Energy, radial and angular distributions extracted from the TrueBeam phase space files published by the manufacturer and from phase spaces tallied with PRIMO for the Clinac 2100 were compared for the 6, 8, 10 and 15 MV flattened-filtered beams. Dose distributions in water computed for the two sets of PSFs were compared with the Varian Representative Beam Data (RBD) for square fields with sides ranging from 3 to 30 cm. Output factors were calculated for square fields with sides ranging from 2 to 40 cm. Results Excellent agreement with the RBD was obtained for the simulations that employed the phase spaces distributed by Varian as well as for those that used the surrogate geometry, reaching in both cases Gamma ( 2%, 2 mm) pass rates larger than 99%, except for the 15 MV surrogate. This result supports previous investigations that suggest a change in the material composition of the TrueBeam 15 MV flattening filter. In order to get the said agreement, PRIMO simulations were run using enlarged transport parameters to compensate the discrepancies between the actual and surrogate geometries. Conclusions This work sustains the claim that the simulation of the 6, 8 and 10 MV flattening-filtered beams of the TrueBeam linac can be performed using the Clinac 2100 model of PRIMO without significant loss of accuracy.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Monte Carlo simulation of backscatter from lead for clinical electron beams using EGSnrc
    Chow, James C. L.
    Grigorov, Grigor N.
    MEDICAL PHYSICS, 2008, 35 (04) : 1241 - 1250
  • [42] Monte Carlo simulation of radiation transport in inhomogeneous phantoms irradiated using stereotactic radiosurgery beams
    Cho, J
    Grein, E
    Robar, J
    Gete, E
    RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S90 - S90
  • [43] Imaging in turbid media by modified filtered back projection method using data from Monte Carlo simulation
    Aggarwal, A
    Vasu, RM
    SMART NONDESTRUCTIVE EVALUATION AND HEALTH MONITORING OF STRUCTURAL AND BIOLOGICAL SYSTEMS II, 2003, 5047 : 314 - 324
  • [44] Monte Carlo simulation of laser beams interaction with the human eye using Geant4
    Diogo Tendeiro
    Gonçalo Lopes
    Pedro Vieira
    José Paulo Santos
    BioMedical Engineering OnLine, 13
  • [45] Monte Carlo simulation of electron beams from medical linac using EGS5
    Nevelsky, A.
    Bar-Deroma, R.
    Orion, I.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S138 - S139
  • [46] Monte Carlo simulation of laser beams interaction with the human eye using Geant4
    Tendeiro, Diogo
    Lopes, Goncalo
    Vieira, Pedro
    Santos, Jose Paulo
    BIOMEDICAL ENGINEERING ONLINE, 2014, 13
  • [47] The Effect of Voxel Size on Dose Distribution in Varian Clinac iX 6 MV Photon Beam Using Monte Carlo Simulation
    Yani, Sitti
    Dirgayussa, I. Gde E.
    Rhani, Moh Fadhillah
    Haryanto, Freddy
    Arif, Idam
    5TH INTERNATIONAL CONFERENCE ON MATHEMATICS AND NATURAL SCIENCES (ICMNS 2014), 2015, 1677
  • [48] Monte Carlo Simulation of a Linac Using PRIMO: User-Friendly Educational Tool Which Can Be Taken to the Cloud for Free
    Bacala, Angelina M.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 1, 2019, 68 (01): : 851 - 854
  • [49] Monte Carlo simulation of MOSFET detectors for high-energy photon beams using the PENELOPE code
    Panettieri, Vanessa
    Duch, Maria Amor
    Jornet, Nuria
    Ginjaume, Merce
    Carrasco, Pablo
    Badal, Andreu
    Ortega, Xavier
    Ribas, Montserrat
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (01): : 303 - 316
  • [50] Monte Carlo Simulation On the Percentage Depth Dose Ratio for the Surface Dosimetry Using Tangential Photon Beams
    Chow, J.
    Grigorov, G.
    MEDICAL PHYSICS, 2008, 35 (06) : 2807 - +