Monte Carlo simulation of the Varian TrueBeam flattened-filtered beams using a surrogate geometry in PRIMO

被引:1
|
作者
Rodriguez, Miguel [1 ,2 ]
Sempau, Josep [3 ,4 ,5 ]
Brualla, Lorenzo [6 ,7 ,8 ,9 ]
机构
[1] Hosp Paitilla, Calle 53 & Ave Balboa, Panama City, Panama
[2] Inst Invest Cient & Serv Alta Tecnol AIP INDICASAT, Edificio 219, Panama City, Panama
[3] Univ Politecn Cataluna, Dept Phys, Diagonal 647, Barcelona 08028, Spain
[4] Univ Politecn Cataluna, Inst Tecn Energet, Diagonal 647, Barcelona 08028, Spain
[5] Ctr Invest Biomed Red Bioingn Biomat & Nanomed CIB, Diagonal 647, Madrid 28029, Spain
[6] Westdeutsches Protonentherapiezentrum Essen WPE, Hufelandstr 55, D-45147 Essen, Germany
[7] West German Canc Ctr WTZ, Hufelandstr 55, D-45147 Essen, Germany
[8] Univ Duisburg Essen, Med Fak, IMIB, Hufelandstr 55, D-45147 Essen, Germany
[9] German Canc Consortium DKTK, Hufelandstr 55, D-45147 Essen, Germany
关键词
Monte Carlo; Phase space; PRIMO; Linear accelerator; IMPLEMENTATION; PENELOPE; PHOTON; CAD;
D O I
10.1186/s13014-024-02405-w
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background Monte Carlo simulation of radiation transport for medical linear accelerators (linacs) requires accurate knowledge of the geometrical description of the linac head. Since the geometry of Varian TrueBeam machines has not been disclosed, the manufacturer distributes phase-space files of the linac patient-independent part to allow researchers to compute absorbed dose distributions using the Monte Carlo method. This approach limits the possibility of achieving an arbitrarily small statistical uncertainty. This work investigates the use of the geometry of the Varian Clinac 2100, which is included in the Monte Carlo system PRIMO, as a surrogate. Methods Energy, radial and angular distributions extracted from the TrueBeam phase space files published by the manufacturer and from phase spaces tallied with PRIMO for the Clinac 2100 were compared for the 6, 8, 10 and 15 MV flattened-filtered beams. Dose distributions in water computed for the two sets of PSFs were compared with the Varian Representative Beam Data (RBD) for square fields with sides ranging from 3 to 30 cm. Output factors were calculated for square fields with sides ranging from 2 to 40 cm. Results Excellent agreement with the RBD was obtained for the simulations that employed the phase spaces distributed by Varian as well as for those that used the surrogate geometry, reaching in both cases Gamma ( 2%, 2 mm) pass rates larger than 99%, except for the 15 MV surrogate. This result supports previous investigations that suggest a change in the material composition of the TrueBeam 15 MV flattening filter. In order to get the said agreement, PRIMO simulations were run using enlarged transport parameters to compensate the discrepancies between the actual and surrogate geometries. Conclusions This work sustains the claim that the simulation of the 6, 8 and 10 MV flattening-filtered beams of the TrueBeam linac can be performed using the Clinac 2100 model of PRIMO without significant loss of accuracy.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Out-Of-Field Dose Comparison for TrueBeam Low Energy Beams for Extended Distances: Measurement Vs Monte Carlo Simulation
    Wijesooriya, K.
    Liyanage, N.
    Kaluarachchi, M.
    Sawkey, D.
    MEDICAL PHYSICS, 2016, 43 (06) : 3615 - 3615
  • [32] Neutron contamination of Varian Clinac iX 10 MV photon beam using Monte Carlo simulation
    Yani, S.
    Tursinah, R.
    Rhani, M. F.
    Soh, R. C. X.
    Haryanto, F.
    Arif, I.
    13TH SOUTH-EAST ASIAN CONGRESS OF MEDICAL PHYSICS 2015 (SEACOMP), 2016, 694
  • [33] Monte Carlo simulation of electron beams from an accelerator head using PENELOPE
    Sempau, J
    Sánchez-Reyes, A
    Salvat, F
    ben Tahar, HO
    Jiang, SB
    Fernández-Varea, JM
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (04): : 1163 - 1186
  • [34] Analysis of inelastic interactions for therapeutic proton beams using Monte Carlo simulation
    Rosenfeld, AB
    Wroe, AJ
    Cornelius, LM
    Reinhard, M
    Alexiev, D
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (06) : 3019 - 3025
  • [35] Monte Carlo simulation of β-γ coincidence system using plastic scintillators in 4π geometry
    Dias, M. S.
    Piuvezam-Filho, H.
    Baccarelli, A. M.
    Takeda, M. N.
    Koskinas, M. F.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01): : 380 - 383
  • [36] Investigation of Electron Contamination on Flattened and Unflattened Varian Clinac iX 6X and 15X Photon Beam Based on Monte Carlo Simulation
    Haryanto, F.
    Rhani, M. F.
    Anam, C.
    Yani, S.
    ATOM INDONESIA, 2022, 48 (02) : 147 - 158
  • [37] A reliability-based optimization method using sequential surrogate model and Monte Carlo simulation
    Li, Xu
    Gong, Chunlin
    Gu, Liangxian
    Jing, Zhao
    Fang, Hai
    Gao, Ruichao
    STRUCTURAL AND MULTIDISCIPLINARY OPTIMIZATION, 2019, 59 (02) : 439 - 460
  • [38] A reliability-based optimization method using sequential surrogate model and Monte Carlo simulation
    Xu Li
    Chunlin Gong
    Liangxian Gu
    Zhao Jing
    Hai Fang
    Ruichao Gao
    Structural and Multidisciplinary Optimization, 2019, 59 : 439 - 460
  • [39] Monte Carlo Simulation On Surface Dose in Preclinical Irradiation Using Monoenergetic Photon Beams
    Vuong, A.
    Chow, J.
    MEDICAL PHYSICS, 2016, 43 (06) : 3620 - 3620
  • [40] Monte Carlo simulation of proton beams and CTs using GATE in a cloud computing environment
    Rowedder, B.
    Ma, B.
    Kuang, Y.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S177 - S178