The Applications and Pitfalls of Cone-Beam Computed Tomography-Based Synthetic Computed Tomography for Adaptive Evaluation in Pencil-Beam Scanning Proton Therapy

被引:2
|
作者
Tsai, Pingfang [1 ]
Tseng, Yu-Lun [2 ,3 ]
Shen, Brian [1 ]
Ackerman, Christopher [4 ]
Zhai, Huifang A. [1 ]
Yu, Francis [1 ]
Simone II, Charles B. [1 ]
Choi, J. Isabelle [1 ]
Lee, Nancy Y. [5 ]
Kabarriti, Rafi [6 ]
Lazarev, Stanislav [7 ]
Johnson, Casey L. [1 ]
Liu, Jiayi [1 ]
Chen, Chin-Cheng [1 ]
Lin, Haibo [1 ]
机构
[1] New York Proton Ctr, New York, NY 10035 USA
[2] Taipei Med Univ, Proton Ctr, Taipei 11031, Taiwan
[3] Taipei Med Univ, Dept Radiat Oncol, Taipei 11031, Taiwan
[4] Calif Protons Ctr Therapy Ctr, San Diego, CA 92121 USA
[5] Mem Sloan Kettering Canc Ctr, Dept Radiat Oncol, New York, NY 10065 USA
[6] Montefiore Med Ctr, Dept Radiat Oncol, Bronx, NY 10467 USA
[7] Icahn Sch Med Mt Sinai, Dept Radiat Oncol, New York, NY 10029 USA
关键词
synthetic CT; proton therapy; cone-beam computed tomography; pencil-beam scanning; adaptive; IMAGE REGISTRATION; SCATTER CORRECTION; DOSE CALCULATION; CT; RADIATION; HEAD;
D O I
10.3390/cancers15205101
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Simple Summary For proton therapy, verification CT (vCT) scans are routinely acquired to ensure the accuracy and precision of treatment delivery, as this approach allows clinicians to monitor and adapt treatment plans based on potential changes to the patient's anatomy and tumor. This study investigates synthetic CT's (sCT) potential as an alternative to vCT scans, focusing on its reliability across various treatment sites. Synthetic CT could offer a more efficient approach and possibly enhance patient experience by reducing the necessity for frequent vCT scans. The consistency between sCT and vCT in terms of image quality and dosimetric impact is crucial. It will allow clinicians to monitor and adjust treatment plans promptly and more accurately based on patients' anatomical changes, potentially optimizing treatment processes and outcomes. The insights from this study are pivotal for refining clinical practices and fostering advancements in treatment strategies, ultimately aiming at precision and accuracy in adaptive treatment.Abstract Purpose: The study evaluates the efficacy of cone-beam computed tomography (CBCT)-based synthetic CTs (sCT) as a potential alternative to verification CT (vCT) for enhanced treatment monitoring and early adaptation in proton therapy. Methods: Seven common treatment sites were studied. Two sets of sCT per case were generated: direct-deformed (DD) sCT and image-correction (IC) sCT. The image qualities and dosimetric impact of the sCT were compared to the same-day vCT. Results: The sCT agreed with vCT in regions of homogeneous tissues such as the brain and breast; however, notable discrepancies were observed in the thorax and abdomen. The sCT outliers existed for DD sCT when there was an anatomy change and for IC sCT in low-density regions. The target coverage exhibited less than a 5% variance in most DD and IC sCT cases when compared to vCT. The Dmax of serial organ-at-risk (OAR) in sCT plans shows greater deviation from vCT than small-volume dose metrics (D0.1cc). The parallel OAR volumetric and mean doses remained consistent, with average deviations below 1.5%. Conclusion: The use of sCT enables precise treatment and prompt early adaptation for proton therapy. The quality assurance of sCT is mandatory in the early stage of clinical implementation.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Evaluation of the nasopalatine canal and variations with cone-beam computed tomography
    Etoz, Meryem
    Sisman, Yildiray
    SURGICAL AND RADIOLOGIC ANATOMY, 2014, 36 (08) : 805 - 812
  • [42] Morphometric evaluation of the temporomandibular joint on cone-beam computed tomography
    Ayyildiz, Elif
    Orhan, Mustafa
    Bahsi, Ilhan
    Yalcin, Eda Didem
    SURGICAL AND RADIOLOGIC ANATOMY, 2021, 43 (06) : 975 - 996
  • [43] Cone-Beam Computed Tomography (CBCT) to Computed Tomography (CT) Image Translation with Perceptual Loss to Eliminate Cone-Beam Artifacts
    Yoo, S.
    Choi, B.
    Park, I.
    Kim, J.
    Kim, H.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [44] Generating synthesized computed tomography (CT) from cone-beam computed tomography (CBCT) using CycleGAN for adaptive radiation therapy
    Liang, Xiao
    Chen, Liyuan
    Dan Nguyen
    Zhou, Zhiguo
    Gu, Xuejun
    Yang, Ming
    Wang, Jing
    Jiang, Steve
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (12):
  • [45] Evaluation of Anatomoradiological Findings on Trigeminal Neuralgia Patients Using Computed Tomography and Cone-Beam Computed Tomography
    Aksoy, Secil
    Sayin Sakul, Arzu
    Gorur, Durmus Ilker
    Sakul, Bayram Ufuk
    Orhan, Kaan
    DIAGNOSTICS, 2022, 12 (01)
  • [46] Experimental fluence-modulated proton computed tomography by pencil beam scanning
    Dedes, George
    Johnson, Robert P.
    Pankuch, Mark
    Detrich, Nick
    Pols, Willemijn M. A.
    Rit, Simon
    Schulte, Reinhard W.
    Parodi, Katia
    Landry, Guillaume
    MEDICAL PHYSICS, 2018, 45 (07) : 3287 - 3296
  • [47] Model based scatter correction for cone-beam computed tomography
    Wiegert, J
    Bertram, M
    Rose, G
    Aach, T
    MEDICAL IMAGING 2005: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2005, 5745 : 271 - 282
  • [48] Artifacts in orthodontic bracket systems in cone-beam computed tomography and multislice computed tomography
    Hirschinger, Veronika
    Hanke, Sebastian
    Hirschfelder, Ursula
    Hofmann, Elisabeth
    JOURNAL OF OROFACIAL ORTHOPEDICS-FORTSCHRITTE DER KIEFERORTHOPADIE, 2015, 76 (02): : 152 - 163
  • [49] Comparison of Cone-Beam Computed Tomography and Multislice Computed Tomography in the Assessment of Extremity Fractures
    Dubreuil, Thibaut
    Mouly, Jerome
    Ltaief-Boudrigua, Aicha
    Martinon, Amanda
    Tilhet-Coartet, Stephane
    Tazarourte, Karim
    Pialat, Jean-Baptiste
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2019, 43 (03) : 372 - 378
  • [50] Supervised deep learning-based synthetic computed tomography from kilovoltage cone-beam computed tomography images for adaptive radiation therapy in head and neck cancer
    Khamfongkhruea, Chirasak
    Prakarnpilas, Tipaporn
    Thongsawad, Sangutid
    Deeharing, Aphisara
    Chanpanya, Thananya
    Mundee, Thunpisit
    Suwanbut, Pattarakan
    Nimjaroen, Kampheang
    RADIATION ONCOLOGY JOURNAL, 2024, 42 (03): : 181 - 191