The Applications and Pitfalls of Cone-Beam Computed Tomography-Based Synthetic Computed Tomography for Adaptive Evaluation in Pencil-Beam Scanning Proton Therapy

被引:2
|
作者
Tsai, Pingfang [1 ]
Tseng, Yu-Lun [2 ,3 ]
Shen, Brian [1 ]
Ackerman, Christopher [4 ]
Zhai, Huifang A. [1 ]
Yu, Francis [1 ]
Simone II, Charles B. [1 ]
Choi, J. Isabelle [1 ]
Lee, Nancy Y. [5 ]
Kabarriti, Rafi [6 ]
Lazarev, Stanislav [7 ]
Johnson, Casey L. [1 ]
Liu, Jiayi [1 ]
Chen, Chin-Cheng [1 ]
Lin, Haibo [1 ]
机构
[1] New York Proton Ctr, New York, NY 10035 USA
[2] Taipei Med Univ, Proton Ctr, Taipei 11031, Taiwan
[3] Taipei Med Univ, Dept Radiat Oncol, Taipei 11031, Taiwan
[4] Calif Protons Ctr Therapy Ctr, San Diego, CA 92121 USA
[5] Mem Sloan Kettering Canc Ctr, Dept Radiat Oncol, New York, NY 10065 USA
[6] Montefiore Med Ctr, Dept Radiat Oncol, Bronx, NY 10467 USA
[7] Icahn Sch Med Mt Sinai, Dept Radiat Oncol, New York, NY 10029 USA
关键词
synthetic CT; proton therapy; cone-beam computed tomography; pencil-beam scanning; adaptive; IMAGE REGISTRATION; SCATTER CORRECTION; DOSE CALCULATION; CT; RADIATION; HEAD;
D O I
10.3390/cancers15205101
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Simple Summary For proton therapy, verification CT (vCT) scans are routinely acquired to ensure the accuracy and precision of treatment delivery, as this approach allows clinicians to monitor and adapt treatment plans based on potential changes to the patient's anatomy and tumor. This study investigates synthetic CT's (sCT) potential as an alternative to vCT scans, focusing on its reliability across various treatment sites. Synthetic CT could offer a more efficient approach and possibly enhance patient experience by reducing the necessity for frequent vCT scans. The consistency between sCT and vCT in terms of image quality and dosimetric impact is crucial. It will allow clinicians to monitor and adjust treatment plans promptly and more accurately based on patients' anatomical changes, potentially optimizing treatment processes and outcomes. The insights from this study are pivotal for refining clinical practices and fostering advancements in treatment strategies, ultimately aiming at precision and accuracy in adaptive treatment.Abstract Purpose: The study evaluates the efficacy of cone-beam computed tomography (CBCT)-based synthetic CTs (sCT) as a potential alternative to verification CT (vCT) for enhanced treatment monitoring and early adaptation in proton therapy. Methods: Seven common treatment sites were studied. Two sets of sCT per case were generated: direct-deformed (DD) sCT and image-correction (IC) sCT. The image qualities and dosimetric impact of the sCT were compared to the same-day vCT. Results: The sCT agreed with vCT in regions of homogeneous tissues such as the brain and breast; however, notable discrepancies were observed in the thorax and abdomen. The sCT outliers existed for DD sCT when there was an anatomy change and for IC sCT in low-density regions. The target coverage exhibited less than a 5% variance in most DD and IC sCT cases when compared to vCT. The Dmax of serial organ-at-risk (OAR) in sCT plans shows greater deviation from vCT than small-volume dose metrics (D0.1cc). The parallel OAR volumetric and mean doses remained consistent, with average deviations below 1.5%. Conclusion: The use of sCT enables precise treatment and prompt early adaptation for proton therapy. The quality assurance of sCT is mandatory in the early stage of clinical implementation.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Evaluation of mastoid pneumatization using cone-beam computed tomography
    Oğuzhan Demirel
    Elif Kaya
    Cemile Özlem Üçok
    Oral Radiology, 2014, 30 : 92 - 97
  • [32] Evaluation of enamel pearls by cone-beam computed tomography (CBCT)
    Akgul, Nilgun
    Caglayan, Fatma
    Durna, Nurhan
    Sumbullu, Muhammed-Akif
    Akgul, Hayati-Murat
    Durna, Dogan
    MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2012, 17 (02): : E218 - E222
  • [33] Morphometric evaluation of the temporomandibular joint on cone-beam computed tomography
    Elif Ayyıldız
    Mustafa Orhan
    İlhan Bahşi
    Eda Didem Yalçin
    Surgical and Radiologic Anatomy, 2021, 43 : 975 - 996
  • [34] Cone-Beam Computed Tomography-Based Three-Dimensional McNamara Cephalometric Analysis
    Goncalves dos Santos, Rodrigo Mologni
    De Martino, Jose Mario
    Haiter Neto, Francisco
    Passeri, Luis Augusto
    JOURNAL OF CRANIOFACIAL SURGERY, 2018, 29 (04) : 895 - 899
  • [35] Evaluation of the nasopalatine canal and variations with cone-beam computed tomography
    Meryem Etoz
    Yıldıray Sisman
    Surgical and Radiologic Anatomy, 2014, 36 : 805 - 812
  • [36] EVALUATION OF DOSE HOMOGENEITY IN CONE-BEAM BREAST COMPUTED TOMOGRAPHY
    Mettivier, Giovanni
    Costa, Matilde
    Lanconelli, Nico
    Ianiro, Anna
    Pugliese, Mariagabriella
    Quarto, Maria
    Russo, Paolo
    RADIATION PROTECTION DOSIMETRY, 2017, 175 (04) : 473 - 481
  • [37] Evaluation of Megavoltage Cone-Beam Computed Tomography Doses in Thoracic Radiation Therapy
    Yan, S.
    Zhu, J.
    Yan, S.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [38] Evaluation of mastoid pneumatization using cone-beam computed tomography
    Demirel, Oguzhan
    Kaya, Elif
    Ucok, Cemile Ozlem
    ORAL RADIOLOGY, 2014, 30 (01) : 92 - 97
  • [39] External beam radiotherapy cone beam computed tomography-based dose calculation
    Barateau, Anais
    Celeste, Marc
    Lafond, Caroline
    Henry, Olivier
    Couespel, Solene
    Simon, Antoine
    Acosta, Oscar
    de Crevoisier, Renaud
    Perichon, Nicolas
    CANCER RADIOTHERAPIE, 2018, 22 (01): : 102 - 103
  • [40] Evaluation of Mandibular Lingual Foramina With Cone-Beam Computed Tomography
    Zhang, Chunan
    Zhuang, Longfei
    Fan, Linfeng
    Mo, Jiaji
    Huang, Zhuoli
    Gu, Yingxin
    JOURNAL OF CRANIOFACIAL SURGERY, 2018, 29 (04) : E389 - E394