The Applications and Pitfalls of Cone-Beam Computed Tomography-Based Synthetic Computed Tomography for Adaptive Evaluation in Pencil-Beam Scanning Proton Therapy

被引:2
|
作者
Tsai, Pingfang [1 ]
Tseng, Yu-Lun [2 ,3 ]
Shen, Brian [1 ]
Ackerman, Christopher [4 ]
Zhai, Huifang A. [1 ]
Yu, Francis [1 ]
Simone II, Charles B. [1 ]
Choi, J. Isabelle [1 ]
Lee, Nancy Y. [5 ]
Kabarriti, Rafi [6 ]
Lazarev, Stanislav [7 ]
Johnson, Casey L. [1 ]
Liu, Jiayi [1 ]
Chen, Chin-Cheng [1 ]
Lin, Haibo [1 ]
机构
[1] New York Proton Ctr, New York, NY 10035 USA
[2] Taipei Med Univ, Proton Ctr, Taipei 11031, Taiwan
[3] Taipei Med Univ, Dept Radiat Oncol, Taipei 11031, Taiwan
[4] Calif Protons Ctr Therapy Ctr, San Diego, CA 92121 USA
[5] Mem Sloan Kettering Canc Ctr, Dept Radiat Oncol, New York, NY 10065 USA
[6] Montefiore Med Ctr, Dept Radiat Oncol, Bronx, NY 10467 USA
[7] Icahn Sch Med Mt Sinai, Dept Radiat Oncol, New York, NY 10029 USA
关键词
synthetic CT; proton therapy; cone-beam computed tomography; pencil-beam scanning; adaptive; IMAGE REGISTRATION; SCATTER CORRECTION; DOSE CALCULATION; CT; RADIATION; HEAD;
D O I
10.3390/cancers15205101
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Simple Summary For proton therapy, verification CT (vCT) scans are routinely acquired to ensure the accuracy and precision of treatment delivery, as this approach allows clinicians to monitor and adapt treatment plans based on potential changes to the patient's anatomy and tumor. This study investigates synthetic CT's (sCT) potential as an alternative to vCT scans, focusing on its reliability across various treatment sites. Synthetic CT could offer a more efficient approach and possibly enhance patient experience by reducing the necessity for frequent vCT scans. The consistency between sCT and vCT in terms of image quality and dosimetric impact is crucial. It will allow clinicians to monitor and adjust treatment plans promptly and more accurately based on patients' anatomical changes, potentially optimizing treatment processes and outcomes. The insights from this study are pivotal for refining clinical practices and fostering advancements in treatment strategies, ultimately aiming at precision and accuracy in adaptive treatment.Abstract Purpose: The study evaluates the efficacy of cone-beam computed tomography (CBCT)-based synthetic CTs (sCT) as a potential alternative to verification CT (vCT) for enhanced treatment monitoring and early adaptation in proton therapy. Methods: Seven common treatment sites were studied. Two sets of sCT per case were generated: direct-deformed (DD) sCT and image-correction (IC) sCT. The image qualities and dosimetric impact of the sCT were compared to the same-day vCT. Results: The sCT agreed with vCT in regions of homogeneous tissues such as the brain and breast; however, notable discrepancies were observed in the thorax and abdomen. The sCT outliers existed for DD sCT when there was an anatomy change and for IC sCT in low-density regions. The target coverage exhibited less than a 5% variance in most DD and IC sCT cases when compared to vCT. The Dmax of serial organ-at-risk (OAR) in sCT plans shows greater deviation from vCT than small-volume dose metrics (D0.1cc). The parallel OAR volumetric and mean doses remained consistent, with average deviations below 1.5%. Conclusion: The use of sCT enables precise treatment and prompt early adaptation for proton therapy. The quality assurance of sCT is mandatory in the early stage of clinical implementation.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] An optimized framework for cone-beam computed tomography-based online evaluation for proton therapy
    Chang, Chih-Wei
    Nilsson, Rasmus
    Andersson, Sebastian
    Bohannon, Duncan
    Patel, Sagar A.
    Patel, Pretesh R.
    Liu, Tian
    Yang, Xiaofeng
    Zhou, Jun
    MEDICAL PHYSICS, 2023, 50 (09) : 5375 - 5386
  • [2] Evaluation of Cone-Beam Computed Tomography-Based Radiomic Features Reproducibility: A Phantom Study
    Adachi, T.
    Nakamura, M.
    Iramina, H.
    Mizowaki, T.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [3] Practical applications of cone-beam computed tomography in orthodontics
    Mah, James K.
    Huang, John C.
    Choo, HyeRan
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2010, 141 (10): : 7S - 13S
  • [4] Intraoperative Endodontic Applications of Cone-Beam Computed Tomography
    Ball, Randy L.
    Barbizam, Joao V.
    Cohenca, Nestor
    JOURNAL OF ENDODONTICS, 2013, 39 (04) : 548 - 557
  • [5] Cone-beam computed tomography for trauma
    Gupta, Saurabh
    Martinson, James R.
    Ricaurte, Daniel
    Scalea, Thomas M.
    Morrison, Jonathan J.
    JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2020, 89 (03): : E34 - E40
  • [6] Industrial computed tomography and its application based on cone-beam scanning
    Min, Y
    Sun, CL
    Zhang, QH
    ISTM/2005: 6th International Symposium on Test and Measurement, Vols 1-9, Conference Proceedings, 2005, : 5758 - 5761
  • [7] Cone-Beam Computed Tomography in Orthodontics
    Abdelkarim, Ahmad
    DENTISTRY JOURNAL, 2019, 7 (03)
  • [8] Adaptive Proton Therapy Dose Evaluation and Planning Using Cone Beam Computed Tomography
    Ackerman, C.
    Tsai, P.
    Zhai, H.
    Kang, M.
    Apinorasethkul, C.
    Bhatti, D.
    Lin, H.
    MEDICAL PHYSICS, 2020, 47 (06) : E694 - E694
  • [9] Progressive auto-segmentation for cone-beam computed tomography-based online adaptive radiotherapy
    Zhao, Hengrui
    Liang, Xiao
    Meng, Boyu
    Dohopolski, Michael
    Choi, Byongsu
    Cai, Bin
    Lin, Mu-Han
    Bai, Ti
    Nguyen, Dan
    Jiang, Steve
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2024, 31
  • [10] Cone-beam Computed Tomography Evaluation of Maxillary Sinusitis
    Maillet, Michelle
    Bowles, Walter R.
    McClanahan, Scott L.
    John, Mike T.
    Ahmad, Mansur
    JOURNAL OF ENDODONTICS, 2011, 37 (06) : 753 - 757