Thermal fatigue analysis of district heating pipeline under variable frequency regulation of circulating water pump

被引:1
|
作者
Liu, Fuqiang [1 ]
Song, Chongfang [1 ]
Pan, Wuxuan [1 ]
Wang, Guowei [2 ]
Zhang, Huijie [1 ]
Lei, Yonggang [1 ]
机构
[1] Taiyuan Univ Technol, Taiyuan, Peoples R China
[2] Taiyuan Municipal Engn Design & Res Inst, Taiyuan 030000, Peoples R China
关键词
District-heating pipelines; Rainflow counting method; Fatigue cycle times; Variable frequency regulation of circulating; water pump;
D O I
10.1016/j.applthermaleng.2024.122535
中图分类号
O414.1 [热力学];
学科分类号
摘要
The use of variable frequency control of circulating water pumps is an important energy-saving operation strategy to cope with changes in heating load. However, it can lead to low cycle fatigue failure of the pipeline when the cyclic stress generated by frequent water temperature fluctuations reaches the fatigue limit. Accurately prediction of the maximum total temperature difference cycles of pipelines is of great significance for ensuring the safe operation of centralized heating networks with frequent water flow rates regulation. Based on the actual operating data of 360,000 heat exchange stations, the stress amplitude and corresponding temperature difference cycles of pipelines at different operating temperatures were calculated, the maximum total temperature difference cycle of pipelines for 30 years was predicted. We calculated the stress limit of pipelines at different safety levels, and evaluated the impact of temperature on the fatigue life of pipelines under different building types and working conditions. The results show that the number of temperature difference cycles in primary network pipelines is three times that in secondary network pipelines, and the number of temperature difference cycles in pipelines of different building types varies greatly. The lower the operating temperature of the pipeline, the smaller the temperature difference fluctuation and the greater the contribution of pipeline fatigue damage when regulating the variable flow rate of the circulating water pump. The stress limit values of primary network supply and return water pipelines are 650 MPa and 759 MPa, while the stress limit values of secondary network supply and return water pipelines are 811 MPa and 946 MPa.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Study on Transient Response Analysis and Fatigue Life Evaluation of Water Pump Volute Casing under Impact Load
    Li, Min
    Yin, Zenghui
    Shi, Kui
    Liu, Jianxin
    Du, Huiyong
    MECHANICAL ENGINEERING AND GREEN MANUFACTURING II, PTS 1 AND 2, 2012, 155-156 : 550 - 554
  • [42] Similitude criterion derivation and pipe physical property test and suitable analysis for water hammner scale model of long distance district heating pipeline
    Hua, Jing
    Zhang, Shigang
    Fu, Lin
    APPLIED THERMAL ENGINEERING, 2017, 125 : 80 - 90
  • [43] Analysis of a Hybrid PV/Thermal Solar-Assisted Heat Pump System for Sports Center Water Heating Application
    Bai, Y.
    Chow, T. T.
    Menezo, C.
    Dupeyrat, P.
    INTERNATIONAL JOURNAL OF PHOTOENERGY, 2012, 2012
  • [44] Theoretical analysis of thermal performance of a direct-expansion solar-assisted heat pump water heating system
    Kuang, YH
    Wang, RZ
    CRYOGENICS AND REFRIGERATION - PROCEEDINGS OF ICCR'2003, 2003, : 686 - 690
  • [45] Numerical modeling and parametric analysis of temperature distribution in soil based on water content variation under radio frequency heating for in-situ thermal remediation
    Qi, Wenhao
    Lou, Wei
    Sheng, Anxu
    Xu, Wenjie
    Luo, Yongqiang
    Wu, Haibin
    Yin, Hao
    Chen, Jing
    Wu, Xiaohui
    Wang, Linling
    Science of the Total Environment, 2024, 957
  • [46] Exergy and energy analysis of a ground-source heat pump for domestic water heating under simulated occupancy conditions
    Ally, Moonis R.
    Munk, Jeffrey D.
    Baxter, Van D.
    Gehl, Anthony C.
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2013, 36 (05) : 1417 - 1430
  • [47] Performance analysis of a CO2 heat pump water heating system under a daily change in a standardized demand
    Yokoyama, Ryohei
    Wakui, Tetsuya
    Kamakari, Junya
    Takemura, Kazuhisa
    ENERGY, 2010, 35 (02) : 718 - 728
  • [48] Failure analysis on circulating water pump of duplex stainless steel in 1000 MW ultra-supercritical thermal power unit
    Ma, Yue-Yue
    Yan, Shi
    Yang, Zhen-Guo
    Qi, Guo-Shui
    He, Xin-You
    ENGINEERING FAILURE ANALYSIS, 2015, 47 : 162 - 177
  • [49] Performance analysis of a novel solar assisted ground source heat pump water heating system with graded thermal energy storage
    Zheng, Zhihang
    Zhou, Jin
    Yang, Ying
    Xu, Feng
    Liu, Hongcheng
    Yan, Yili
    ENERGY CONVERSION AND MANAGEMENT, 2023, 288
  • [50] Transient Thermal Analysis of Cooling Water of a Canned Motor for the Nuclear Main Pump Under Secondary Water Supply Outage Condition
    Lu, Yiping
    Ai, Likun
    Sun, Haifeng
    Suo, Wenxu
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2024, 44 (14): : 5756 - 5763