Thermal fatigue analysis of district heating pipeline under variable frequency regulation of circulating water pump

被引:1
|
作者
Liu, Fuqiang [1 ]
Song, Chongfang [1 ]
Pan, Wuxuan [1 ]
Wang, Guowei [2 ]
Zhang, Huijie [1 ]
Lei, Yonggang [1 ]
机构
[1] Taiyuan Univ Technol, Taiyuan, Peoples R China
[2] Taiyuan Municipal Engn Design & Res Inst, Taiyuan 030000, Peoples R China
关键词
District-heating pipelines; Rainflow counting method; Fatigue cycle times; Variable frequency regulation of circulating; water pump;
D O I
10.1016/j.applthermaleng.2024.122535
中图分类号
O414.1 [热力学];
学科分类号
摘要
The use of variable frequency control of circulating water pumps is an important energy-saving operation strategy to cope with changes in heating load. However, it can lead to low cycle fatigue failure of the pipeline when the cyclic stress generated by frequent water temperature fluctuations reaches the fatigue limit. Accurately prediction of the maximum total temperature difference cycles of pipelines is of great significance for ensuring the safe operation of centralized heating networks with frequent water flow rates regulation. Based on the actual operating data of 360,000 heat exchange stations, the stress amplitude and corresponding temperature difference cycles of pipelines at different operating temperatures were calculated, the maximum total temperature difference cycle of pipelines for 30 years was predicted. We calculated the stress limit of pipelines at different safety levels, and evaluated the impact of temperature on the fatigue life of pipelines under different building types and working conditions. The results show that the number of temperature difference cycles in primary network pipelines is three times that in secondary network pipelines, and the number of temperature difference cycles in pipelines of different building types varies greatly. The lower the operating temperature of the pipeline, the smaller the temperature difference fluctuation and the greater the contribution of pipeline fatigue damage when regulating the variable flow rate of the circulating water pump. The stress limit values of primary network supply and return water pipelines are 650 MPa and 759 MPa, while the stress limit values of secondary network supply and return water pipelines are 811 MPa and 946 MPa.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] THE INSTALLATION POSITION ANALYSIS OF A CIRCULATOR PUMP AT WATER HEATING THERMAL POWER STATION WITH OPEN EXPANSION VESSEL
    Cikic, Ante
    Pavec, Kristijan
    TEHNICKI GLASNIK-TECHNICAL JOURNAL, 2013, 7 (03): : 247 - 251
  • [32] Thermal analysis of a water source heat pump for space heating using an outdoor pool as a heat source
    Cardemil, J. M.
    Schneider, W.
    Behzad, M.
    Starke, A. R.
    JOURNAL OF BUILDING ENGINEERING, 2021, 33
  • [33] Dynamic thermal analysis of a coupled solar water heaters-thermal storage tank for solar powered district heating networks
    Lamrani, Bilal
    Belcaid, Aicha
    Lebrouhi, Badr Eddine
    Khodadadi, Jay M.
    El Rhafiki, Tarik
    JOURNAL OF ENERGY STORAGE, 2023, 61
  • [34] Numerical analysis of the operation regulation in a solar heating system with seasonal water pool thermal storage
    Zhao, Jinling
    Lyu, Lianyi
    Li, Xuexin
    RENEWABLE ENERGY, 2020, 150 : 1118 - 1126
  • [36] Thermal economic analysis of auxiliary heat source of solar-assisted heat pump water heating system
    Mu, Zhen-Ying
    You, Shi-Jun
    Tianjin Daxue Xuebao (Ziran Kexue yu Gongcheng Jishu Ban)/Journal of Tianjin University Science and Technology, 2010, 43 (11): : 995 - 1002
  • [37] Analysis of the operating characteristics of hybrid heat sources: heat pump water heater under variable conditions
    Zhao, Weiqiang
    Li, Shuhong
    Zhang, Xiaosong
    Huagong Jinzhan/Chemical Industry and Engineering Progress, 2017, 36 (11): : 3977 - 3985
  • [38] Study on Analogue Simulation of the Influences of Thermal Parameters on the Performance of Water Source Heat Pump under Variable Working Condition
    Qu, Shilin
    Luo, Hanqing
    FRONTIERS OF GREEN BUILDING, MATERIALS AND CIVIL ENGINEERING, PTS 1-8, 2011, 71-78 : 3789 - +
  • [39] Variable- frequency operation performance of air source carbon dioxide heat pump water heater under high inlet water temperature
    Wang, Qinrong
    Luo, Huilong
    Du, Peijian
    Yang, Xiaochuan
    Kou, Hongqiao
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2020, 41 (08): : 1 - 6
  • [40] Analysis of thermal performance characteristics in variable header solar water heating system by a swirling effect of twisted tapes
    Thulasi, Selvam
    Jaisankar, Subramanian
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2022, 44 (04) : 10630 - 10646