Accumulated Dose Deviation of Rotational and Residual Setup Errors on Nasopharyngeal Carcinoma Using MIM Treated by Helical Tomotherapy

被引:0
|
作者
Yao, Wenyan [1 ,2 ,3 ]
Hu, Jiang [1 ,2 ,3 ]
Xu, Peixun [1 ,2 ,3 ]
He, Mengxue [1 ,2 ,3 ]
Fang, Yongwen [1 ,2 ,3 ]
Liu, Mingzhi [1 ,2 ,3 ]
Li, Zongtai [1 ,2 ,3 ]
He, Huilang [1 ,2 ,3 ]
Liu, Hui [1 ,2 ,3 ]
Sun, Wenzhao [1 ,2 ,3 ]
Xu, Senkui [1 ,2 ,3 ,4 ]
机构
[1] Sun Yat Sun Univ, Canc Ctr, Guangzhou, Peoples R China
[2] State Key Lab Oncol South China, Guangzhou, Peoples R China
[3] Guangdong Key Lab Nasopharyngeal Carcinoma Diag &, Guangzhou, Peoples R China
[4] Sun Yat sen Univ, Canc Ctr, Guangzhou 510060, Peoples R China
关键词
setup errors; deformable image registration; helical tomotherapy; nasopharyngeal carcinoma; megavolt-level computed tomography;
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: To analyze the relationship between the rotational and residual setup errors and the dose deviation on nasopharyngeal carcinoma (NPC) treated by helical tomotherapy (HT). Methods: From 25 July 2017 to 20 August 2019, 16 treated NPC patients were enrolled in the study. These patients were scanned with full target range megavoltage computed tomography (MVCT) every other day. Adaptive radiotherapy function application software MIM7.1.3 were used to accumulate the actual dose. The dose deviation with the initial plan dose of the patients' target and organs at risk (OAR) were compared, and the correlation between the dose change and the setup errors (rotational setup errors and neck residual setup error) was analyzed. Results: Translational setup errors increased farther away from the head. Statistically significant difference among 3 groups was achieved in the directions of left-right (P < .001) and anteroposterior (P < .001) by analysis of variance test. Compared with the initial plan dose, the actual accumulated dose of the target area decreased with the actual exposure dose of the OAR increased. However, most of the dosimetric parameters differed by less than 5%. No correlation was found between dose deviation values and the translational setup errors of target. However, sagittal rotational setup errors (pitch) had a positive relationship (P < .05) with the avearge dose of PTVnd (L) (r = 0.885), PTVnd(R) (r = 0.547) PTV1(r = 0.633) and PTV2(r = 0.584). Transverse rotational setup errors (roll) had a positive relationship (P < .05) with the avearge dose of PTVnd(R) (r = 0.593), PTV1(r = 0.505) and PTV2(r = 0.662). Conclusions: Dose deviation between the actual accumulated and initial plan is not negligible, but most indicators difference is less than 5%, NPC patients treated by HT with MVCT correction setup errors every other day did not need adaptive radiotherapy model unless got rapid tumor shrinkage or weight loss. Moreover, to minimize the dose deviation, more attention should be paid to the reduction of pitch, roll, and residual error of cervical vertebrae during body positioning.
引用
收藏
页数:8
相关论文
共 47 条
  • [21] Improving target coverage using target-volume-separating technique in helical tomotherapy for patients with nasopharyngeal carcinoma
    Jeon, B.
    Keum, K.
    Kim, J.
    Kim, Y.
    Lee, I.
    Cho, J.
    Lee, C.
    Suh, C.
    Kim, G.
    Seong, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S603 - S603
  • [22] Sparing submandibular gland to alleviating acute xerostomia in patients with nasopharyngeal carcinoma treated with helical tomotherapy: Evaluation by diffusion kurtosis imaging
    Zhao, Da-wei
    Fan, Wen-jun
    Fang, Xue-mei
    Luo, Yan-rong
    Wei, Jian
    Chen, Nan-xiang
    Zhang, Xin-xin
    Liu, Gang
    Li, Jin-feng
    Zang, Xiao
    Li, Meng
    Meng, Lingling
    Ma, Lin
    RADIOTHERAPY AND ONCOLOGY, 2022, 172 : 91 - 98
  • [23] The ratio of weight loss to planning target volume significantly impacts setup errors in nasopharyngeal cancer patients undergoing helical tomotherapy with daily megavoltage computed tomography
    Hou, Wei-Hsien
    Wang, Chun-Wei
    Tsai, Chiao-Ling
    Hsu, Feng-Ming
    Cheng, Jason Chia-Hsien
    RADIOLOGY AND ONCOLOGY, 2016, 50 (04) : 427 - 432
  • [24] Dose variation of critical structures in daily treatment of nasopharyngeal cancer patients using helical tomotherapy megavoltage CT system
    Han, C.
    Chen, Y.
    Liu, A.
    Schultheiss, T.
    Wong, J.
    MEDICAL PHYSICS, 2007, 34 (06) : 2393 - 2393
  • [25] Preliminary Study of a Novel Deep-Learning Method for Voxel-By-Voxel Dose Prediction in the Nasopharyngeal Cancers Treated by Helical Tomotherapy
    Liu, Z.
    Liu, Z.
    Dai, J.
    MEDICAL PHYSICS, 2018, 45 (06) : E140 - E141
  • [26] Treatment of nasopharyngeal carcinoma using simultaneous modulated accelerated radiation therapy via helical tomotherapy: a phase II study
    Du, Lei
    Zhang, Xin Xin
    Feng, Lin Chun
    Chen, Jing
    Yang, Jun
    Liu, Hai Xia
    Xu, Shou Ping
    Xie, Chuan Bin
    Ma, Lin
    RADIOLOGY AND ONCOLOGY, 2016, 50 (02) : 218 - 225
  • [27] CLINICAL FEASIBILITY OF USING FILM-BASED, IN VIVO DOSIMETRY TO DETECT SETUP ERRORS DURING STEREOTACTIC BODY RADIOTHERAPY TREATMENTS USING HELICAL TOMOTHERAPY
    Giantsoudi, D.
    Gutierrez, A.
    Shi, C.
    Papanikolaou, N.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S381 - S382
  • [28] High Control Rate for Lymph Nodes in Cervical Cancer Treated with High-Dose Radiotherapy using Helical Tomotherapy
    Kim, Y. J.
    Kim, J. Y.
    Yoo, S. H.
    Min, B. J.
    Chung, K. Z.
    Seo, S. S.
    Kang, S. B.
    Lim, M. C.
    Hwang, J. H.
    Yoo, H. J.
    Park, S. Y.
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2013, 12 (01) : 45 - 51
  • [29] Evaluation of dose changes to target and critical structures from rotational setup errors (RSE) in prostate cancer patients treated with proton therapy
    Sejpal, S. V.
    Amos, R. A.
    Bluett, J. B.
    Levy, L. B.
    Kudchadker, R. J.
    Johnson, J.
    Choi, S.
    Lee, A. K.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S321 - S321
  • [30] A Risk Prediction Model by LASSO for Radiation-Induced Xerostomia in Patients With Nasopharyngeal Carcinoma Treated With Comprehensive Salivary Gland-Sparing Helical Tomotherapy Technique
    Teng, Feng
    Fan, Wenjun
    Luo, Yanrong
    Xu, Shouping
    Gong, Hanshun
    Ge, Ruigang
    Zhang, Xinxin
    Wang, Xiaoning
    Ma, Lin
    FRONTIERS IN ONCOLOGY, 2021, 11