Dose variation of critical structures in daily treatment of nasopharyngeal cancer patients using helical tomotherapy megavoltage CT system

被引:0
|
作者
Han, C. [1 ]
Chen, Y. [1 ]
Liu, A. [1 ]
Schultheiss, T. [1 ]
Wong, J. [1 ]
机构
[1] City Hope Natl Med Ctr, Duarte, CA 91010 USA
关键词
D O I
10.1118/1.2760613
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To study daily spinal cord and parotid gland dose variation for nasopharyngeal cancer patients undergoing helical tomotherapy treatments, as a result of patient weight loss during the course of treatments. Method and Materials: Five nasopharygeal cancer patients who received helical tomotherapy treatments were selected. At the end of the treatments, patients lost an average weight of 6.3 kg, or 8.4% relative to the weight at the beginning of the treatments. Daily megavoltage CT (MVCT) scans were performed prior to each treatment fraction, and MVCT images were registered with planning CT images for patient setup corrections. Contours for spinal cord and parotid glands were drawn on MVCT images throughout the treatment course. Based on daily MVCT images, actual dose delivered to the critical structures were calculated using the Planned Adaptive application in the helical tomotherapy treatment planning system. The maximum dose to the spinal cord and the median doses to the parotid glands were analyzed. Results: The maximum dose to the spinal cord, after setup corrections, did not show significant variation as a result of patient weight loss. However, the median doses to the parotid glands showed significant increase due to facial tissue shrinkage during treatments. The average median dose to the parotid glands for the five patients were 83 cGy for the first treatment fraction, and it was 143 cGy per fraction for the last fraction. The average parotid gland volume decreased from 20.5 cc to 13.2 cc during treatments. Conclusion: Daily patient setup corrections based on MVCT image registrations prevented significant dose variation to the spinal cord due to setup uncertainty. During the course of radiotherapy, as a result of body weight loss, the parotid glands typically receive significantly higher dose compared to the dose dictated in the treatment plan. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2393 / 2393
页数:1
相关论文
共 50 条
  • [1] Critical structure dose variation in daily treatment of nasopharyngeal cancer patients based on helical tomotherapy megavoltage CT images
    Han, C.
    Chen, Y.
    Liu, A.
    Schultheiss, T. E.
    Wong, J. Y. C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S417 - S417
  • [2] Evaluation of dose delivery variations in Helical Tomotherapy using Helical Megavoltage CT images
    Stathakis, S.
    Mavroidis, P.
    Papanikolaou, N.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S187 - S188
  • [3] Dose Verification and Plan Adaptation in Megavoltage CT Guided Total Body Irradiation using Helical Tomotherapy
    Chao, M.
    Penagaricano, J.
    Moros, E.
    Corry, P.
    Ratanatharathorn, V.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S632 - S632
  • [4] Daily megavoltage CT imaging for lung cancer during a course of external beam radiotherapy with a helical tomotherapy device
    Meeks, SL
    Langer, K
    Kupelian, PA
    Jenkins, W
    Buchholz, D
    Poole, D
    Zhang, Y
    Forbes, A
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (01): : S337 - S338
  • [5] Comparison of the effectiveness of different immobilization systems in different body regions using daily megavoltage CT in helical tomotherapy
    Cheng, K-F
    Wu, V. W. C.
    BRITISH JOURNAL OF RADIOLOGY, 2014, 87 (1034):
  • [6] Feasibility of Megavoltage CT for High-Dose Retrospective Planning of Helical Tomotherapy and Linac Treatment Plans: Hepatocellular Carcinoma Cancer Case
    Syafi’i, Ahmad
    Nasution, Nuruddin
    Wibowo, Wahyu Edy
    Kodrat, Henry
    Pawiro, Supriyanto Ardjo
    Iranian Journal of Medical Physics, 2022, 19 (02): : 106 - 114
  • [7] Normal tissue dose and second cancer risk due to megavoltage fan-beam CT, static tomotherapy and helical tomotherapy in breast radiotherapy
    Quinn, Alexandra
    Holloway, Lois
    Hardcastle, Nicholas
    Tome, Wolfgang A.
    Rosenfeld, Anatoly
    Metcalfe, Peter
    RADIOTHERAPY AND ONCOLOGY, 2013, 108 (02) : 266 - 268
  • [8] Expected clinical impact of the differences between planned and delivered dose distributions in helical tomotherapy for treating head and neck cancer using helical megavoltage CT images
    Mavroidis, Panayiotis
    Stathakis, Sotirios
    Gutierrez, Alonso
    Esquivel, Carlos
    Shi, Chenyu
    Papanikolaou, Nikos
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2009, 10 (03): : 125 - 139
  • [9] The ratio of weight loss to planning target volume significantly impacts setup errors in nasopharyngeal cancer patients undergoing helical tomotherapy with daily megavoltage computed tomography
    Hou, Wei-Hsien
    Wang, Chun-Wei
    Tsai, Chiao-Ling
    Hsu, Feng-Ming
    Cheng, Jason Chia-Hsien
    RADIOLOGY AND ONCOLOGY, 2016, 50 (04) : 427 - 432
  • [10] Evaluation of helical tomotherapy megavoltage CT system for daily automatic patient setup correction and manual prostate gland motion correction
    Han, C.
    Schultheiss, T.
    Liu, A.
    Wong, J.
    MEDICAL PHYSICS, 2006, 33 (06) : 1988 - 1988