Validation of the fractional exhaled breath temperature measurement: reference values

被引:0
|
作者
Sipos, Ivana Huljev [1 ]
Sipos, Kristijan [2 ]
Steiner, Justinija [3 ]
Rotkvic, Petra Grubic [4 ]
Ljubicic, Divo [1 ]
Sola, Ana Marija [5 ]
Vukovac, Emilija Lozo [6 ]
Keres, Tatjana [7 ]
Plavec, Davor [8 ]
机构
[1] Univ Hosp Dubrava, Dept Pulmonol, Zagreb, Croatia
[2] Clin Cardiovasc Dis Magdalena, Dept Cardiol, Krapinske Toplice, Croatia
[3] Osijek Baranja Country Med Ctr, Osijek, Croatia
[4] Univ Hosp Sveti Duh, Dept Cardiol, Zagreb, Croatia
[5] Special Hosp Pulm Dis, Dept Pulmonol, Zagreb, Croatia
[6] Univ Hosp Split, Dept Pulmonol, Split, Croatia
[7] Univ Hosp Dubrava, Dept Intens Care, Zagreb, Croatia
[8] JJ Strossmayer Univ Osijek, Fac Med, Osijek, Croatia
关键词
temperature; breath; fractions; validation; airways; PHYSICAL-ACTIVITY; EXERCISE; ASTHMATICS; MARKERS; PROTEIN; PLASMA;
D O I
10.1088/1752-7163/acb598
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Exhaled breath temperature (EBT) is a known biomarker of inflammation and airways blood flow. As opposed to previous studies, we were able to measure temperature of separate fractions of exhaled breath (fEBT) (those from the peripheral and central airways). The aim was to validate the fEBT measurement method to determine the reference values and the influence of endogenous and exogenous factors on fEBT in healthy subjects. This cross-sectional study included 55 healthy adults in whom fEBT was repeatedly measured, two days in a row, using a FractAir((R)) device. Also, basal metabolic rate, level of physical activity, distance from the main road, outdoor and ambient temperature, air pressure and humidity, haematology and inflammation markers, lung function, cumulative EBT and body temperature at characteristic points on the body were measured. The results showed that fEBT from central airways was lower compared to fEBT from the periphery and that fEBTs were not related to body temperature (p > 0.05 for all). We also showed repeatability of fEBT measurements for two consecutive days. All EBT fractions correlated significantly with ambient temperature (<0.01). No associations of fEBT with other personal and external factors were found using multivariate analysis. At room temperature of 22 degrees C, the physiological temperature values of the first fraction were 23.481 +/- 3.150 degrees C, the second fraction 26.114 +/- 4.024 degrees C and the third fraction 28.216 +/- 3.321 degrees C. The proposed reference values represent the first part of validation of fEBT as the method for the use in clinical practice.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Towards Reference Values for Malondialdehyde on Exhaled Breath Condensate: A Systematic Literature Review and Meta-Analysis
    Turcu, Veronica
    Wild, Pascal
    Hemmendinger, Maud
    Sauvain, Jean-Jacques
    Bergamaschi, Enrico
    Hopf, Nancy B.
    Canu, Irina Guseva
    TOXICS, 2022, 10 (05)
  • [32] Fast and Accurate Exhaled Breath Ammonia Measurement
    Solga, Steven F.
    Mudalel, Matthew L.
    Spacek, Lisa A.
    Risby, Terence H.
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2014, (88):
  • [33] A hydrogen peroxide sensor for exhaled breath measurement
    Anh, DTV
    Olthuis, W
    Bergveld, P
    SENSORS AND ACTUATORS B-CHEMICAL, 2005, 111 : 494 - 499
  • [34] Single breath measurement of exhaled ethane.
    Paredi, P
    Leak, D
    Ward, S
    Cramer, D
    Kharitonov, SA
    Barnes, PJ
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1999, 159 (03) : A887 - A887
  • [35] Importance of type and degree of IgE sensitisation for defining fractional exhaled nitric oxide reference values
    Zaigham, Suneela
    Zhou, Xingwu
    Molin, Magnus
    Sjolander, Anders
    Moverare, Robert
    Janson, Christer
    Malinovschi, Andrei
    RESPIRATORY MEDICINE, 2021, 188
  • [36] Importance of type and degree of IgE sensitisation for defining fractional exhaled nitric oxide reference values
    Zaigham, Suneela
    Zhou, Xingwu
    Molin, Magnus
    Sjolander, Anders
    Moverare, Robert
    Janson, Christer
    Malinovschi, Andrei
    EUROPEAN RESPIRATORY JOURNAL, 2021, 58
  • [37] Differential measurement of exhaled breath temperature allows characterization of the spread of inflammation in airways diseases
    Nora Gonzalez-Diaz, Sandra
    Ivett Guzman-Avilan, Rosa
    Virginia Villarreal-Gonzalez, Rosalaura
    Elizabeth De Lira-Quezada, Cindy
    Popov, Todor
    Ansotegui-Zubeldia, Ignacio
    Sanchez-Borges, Mario
    EUROPEAN RESPIRATORY JOURNAL, 2019, 54
  • [38] Measurement of the fraction of exhaled breath temperature as a biomarker of asthma control in patients in northeastern Mexico
    Elizabeth de Lira-Quezada, Cindy
    Nora Gonzalez-Diaz, Sandra
    Arias Cruz, Alfredo
    Elizondo Villarreal, Barbara
    Macouzet-Sanchez, Carlos
    Galindo-Rodriguez, Gabriela
    Virginia Villarreal-Gonzalez, Rosalaura
    Ivett Guzman-Avilan, Rosa
    Sanchez-Guerra, Daniel
    Soto-Zamora, Emilio G.
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2018, 141 (02) : AB98 - AB98
  • [39] Breath condenser coatings affect measurement of biomarkers in exhaled breath condensate
    Rosias, P. P.
    Robroeks, C. M.
    Niemarkt, H. J.
    Kester, A. D.
    Vernooy, J. H.
    Suykerbuyk, J.
    Teunissen, J.
    Heynens, J.
    Hendriks, H. J.
    Jobsis, Q.
    Dompeling, E.
    EUROPEAN RESPIRATORY JOURNAL, 2006, 28 (05) : 1036 - 1041
  • [40] Validation of nitrite and nitrate measurements in exhaled breath condensate
    Chladkova, J
    Krcmova, I
    Chladek, J
    Cap, P
    Micuda, S
    Hanzalkova, Y
    RESPIRATION, 2006, 73 (02) : 173 - 179