Validation of the fractional exhaled breath temperature measurement: reference values

被引:0
|
作者
Sipos, Ivana Huljev [1 ]
Sipos, Kristijan [2 ]
Steiner, Justinija [3 ]
Rotkvic, Petra Grubic [4 ]
Ljubicic, Divo [1 ]
Sola, Ana Marija [5 ]
Vukovac, Emilija Lozo [6 ]
Keres, Tatjana [7 ]
Plavec, Davor [8 ]
机构
[1] Univ Hosp Dubrava, Dept Pulmonol, Zagreb, Croatia
[2] Clin Cardiovasc Dis Magdalena, Dept Cardiol, Krapinske Toplice, Croatia
[3] Osijek Baranja Country Med Ctr, Osijek, Croatia
[4] Univ Hosp Sveti Duh, Dept Cardiol, Zagreb, Croatia
[5] Special Hosp Pulm Dis, Dept Pulmonol, Zagreb, Croatia
[6] Univ Hosp Split, Dept Pulmonol, Split, Croatia
[7] Univ Hosp Dubrava, Dept Intens Care, Zagreb, Croatia
[8] JJ Strossmayer Univ Osijek, Fac Med, Osijek, Croatia
关键词
temperature; breath; fractions; validation; airways; PHYSICAL-ACTIVITY; EXERCISE; ASTHMATICS; MARKERS; PROTEIN; PLASMA;
D O I
10.1088/1752-7163/acb598
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Exhaled breath temperature (EBT) is a known biomarker of inflammation and airways blood flow. As opposed to previous studies, we were able to measure temperature of separate fractions of exhaled breath (fEBT) (those from the peripheral and central airways). The aim was to validate the fEBT measurement method to determine the reference values and the influence of endogenous and exogenous factors on fEBT in healthy subjects. This cross-sectional study included 55 healthy adults in whom fEBT was repeatedly measured, two days in a row, using a FractAir((R)) device. Also, basal metabolic rate, level of physical activity, distance from the main road, outdoor and ambient temperature, air pressure and humidity, haematology and inflammation markers, lung function, cumulative EBT and body temperature at characteristic points on the body were measured. The results showed that fEBT from central airways was lower compared to fEBT from the periphery and that fEBTs were not related to body temperature (p > 0.05 for all). We also showed repeatability of fEBT measurements for two consecutive days. All EBT fractions correlated significantly with ambient temperature (<0.01). No associations of fEBT with other personal and external factors were found using multivariate analysis. At room temperature of 22 degrees C, the physiological temperature values of the first fraction were 23.481 +/- 3.150 degrees C, the second fraction 26.114 +/- 4.024 degrees C and the third fraction 28.216 +/- 3.321 degrees C. The proposed reference values represent the first part of validation of fEBT as the method for the use in clinical practice.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Determination of fractional exhaled nitric oxide (FENO) reference values in healthy Thai population
    Suksawat, Yiwa
    Pacharn, Punchama
    Jirapongsananuruk, Orathaij
    Visitsunthorn, Nualanong
    ASIAN PACIFIC JOURNAL OF ALLERGY AND IMMUNOLOGY, 2017, 35 (03): : 127 - 131
  • [22] Reference Values and Determinants Of Fractional Concentration Of Exhaled Nitric Oxide (FeNO) In Healthy Children
    Jung, Young Ho
    Cho, Hyun Ju
    Kwon, Ji-Won
    Yang, Song I.
    Lee, Eun
    Kim, Hyung Young
    Seo, Ju-Hee
    Kim, Byoung-Ju
    Kim, Hyo-Bin
    Lee, So Yeon
    Song, Dae Jin
    Kim, Woo Kyung
    Jang, Gwang Cheon
    Shim, Jung Yeon
    Hong, Soo-Jong
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2014, 133 (02) : AB84 - AB84
  • [23] Measurement of exhaled breath temperature in patients under general anesthesia: A feasibility study
    Guo, Libo
    Shi, Jinghui
    Liu, Desheng
    Wang, Yue
    Tong, Hongshuang
    Feng, Yue
    Yu, Pulin
    Lv, Yanji
    Li, Enyou
    Wang, Changsong
    BIOMEDICAL REPORTS, 2023, 18 (03)
  • [24] Exhaled breath temperature: broadening the horizons
    Kralimarkova, Tanya Z.
    Popov, Todor A.
    INTERNATIONAL JOURNAL OF TUBERCULOSIS AND LUNG DISEASE, 2014, 18 (02) : 250 - 251
  • [25] Daily Monitoring of Asthmatics by Means of Individual Devices for Exhaled Breath Temperature Measurement
    Popov, Todor A.
    Kralimarkova, Tanya Z.
    Lazarova, Cvetelina T.
    Tzachev, Christo T.
    Dimitrov, Vasil D.
    Gill, Jas
    IEEE SENSORS JOURNAL, 2010, 10 (01) : 44 - 48
  • [26] Exhaled breath temperature in COPD patients
    Garcia, Gabriel
    Bergna, Miguel
    Lopez, Orlando
    EUROPEAN RESPIRATORY JOURNAL, 2012, 40
  • [27] Exhaled breath temperature in airways disease
    McCafferty, JB
    Innes, JA
    EUROPEAN RESPIRATORY JOURNAL, 2003, 22 (02) : 393 - 394
  • [28] Exhaled Breath Temperature and Tobacco Smoking
    Kralimarkova, T. Z.
    Mincheva, R. K.
    Dimitrov, V. D.
    Gill, J. S.
    Popov, T. A.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2010, 181
  • [29] Exhaled breath temperature in elites swimmers
    Couto, M.
    Santos, P.
    Silva, D.
    Martins, C.
    Delgado, L.
    Moreira, A.
    ALLERGY, 2014, 69 : 213 - 213
  • [30] OFFLINE FRACTIONAL EXHALED NITRIC OXIDE AND BREATH FREQUENCY
    Howard, C.
    MacBean, V.
    Lunt, A.
    Greenough, A.
    THORAX, 2015, 70 : A223 - A224