Validation of the fractional exhaled breath temperature measurement: reference values

被引:0
|
作者
Sipos, Ivana Huljev [1 ]
Sipos, Kristijan [2 ]
Steiner, Justinija [3 ]
Rotkvic, Petra Grubic [4 ]
Ljubicic, Divo [1 ]
Sola, Ana Marija [5 ]
Vukovac, Emilija Lozo [6 ]
Keres, Tatjana [7 ]
Plavec, Davor [8 ]
机构
[1] Univ Hosp Dubrava, Dept Pulmonol, Zagreb, Croatia
[2] Clin Cardiovasc Dis Magdalena, Dept Cardiol, Krapinske Toplice, Croatia
[3] Osijek Baranja Country Med Ctr, Osijek, Croatia
[4] Univ Hosp Sveti Duh, Dept Cardiol, Zagreb, Croatia
[5] Special Hosp Pulm Dis, Dept Pulmonol, Zagreb, Croatia
[6] Univ Hosp Split, Dept Pulmonol, Split, Croatia
[7] Univ Hosp Dubrava, Dept Intens Care, Zagreb, Croatia
[8] JJ Strossmayer Univ Osijek, Fac Med, Osijek, Croatia
关键词
temperature; breath; fractions; validation; airways; PHYSICAL-ACTIVITY; EXERCISE; ASTHMATICS; MARKERS; PROTEIN; PLASMA;
D O I
10.1088/1752-7163/acb598
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Exhaled breath temperature (EBT) is a known biomarker of inflammation and airways blood flow. As opposed to previous studies, we were able to measure temperature of separate fractions of exhaled breath (fEBT) (those from the peripheral and central airways). The aim was to validate the fEBT measurement method to determine the reference values and the influence of endogenous and exogenous factors on fEBT in healthy subjects. This cross-sectional study included 55 healthy adults in whom fEBT was repeatedly measured, two days in a row, using a FractAir((R)) device. Also, basal metabolic rate, level of physical activity, distance from the main road, outdoor and ambient temperature, air pressure and humidity, haematology and inflammation markers, lung function, cumulative EBT and body temperature at characteristic points on the body were measured. The results showed that fEBT from central airways was lower compared to fEBT from the periphery and that fEBTs were not related to body temperature (p > 0.05 for all). We also showed repeatability of fEBT measurements for two consecutive days. All EBT fractions correlated significantly with ambient temperature (<0.01). No associations of fEBT with other personal and external factors were found using multivariate analysis. At room temperature of 22 degrees C, the physiological temperature values of the first fraction were 23.481 +/- 3.150 degrees C, the second fraction 26.114 +/- 4.024 degrees C and the third fraction 28.216 +/- 3.321 degrees C. The proposed reference values represent the first part of validation of fEBT as the method for the use in clinical practice.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Validation of the Exhaled Breath Temperature Measure Reference Values in Healthy Subjects
    Carpagnano, Giovanna E.
    Foschino-Barbaro, Maria P.
    Crocetta, Corrado
    Lacedonia, Donato
    Saliani, Valerio
    Zoppo, Luigi Davide
    Barnes, Peter J.
    CHEST, 2017, 151 (04) : 855 - 860
  • [2] Reference values for exhaled breath temperature in healthy subjects aged 17 to 25 years old
    Tavares, Barbara
    Goncalves, Ivania
    Gomes, Sandra
    Jacinto, Tiago
    EUROPEAN RESPIRATORY JOURNAL, 2012, 40
  • [3] Exhaled breath temperature measurement: Applicability in childhood
    Popov, Todor A.
    Kralimarkova, Tanya Z.
    PEDIATRIC PULMONOLOGY, 2016, 51 (01) : 91 - 92
  • [4] Exhaled Breath Temperature Measurement Made Easy
    Popov, Todor A.
    Kralimarkova, Tanya
    Tzachev, Christo
    Dimitrov, Vasil
    Mun, Kuan Keng
    Gill, Jas
    PEDIATRIC ALLERGY AND IMMUNOLOGY, 2009, 20 (02) : 200 - 201
  • [5] Measurement of temperature and relative humidity in exhaled breath
    Mansour, Elias
    Vishinkin, Rotem
    Rihet, Stephane
    Saliba, Walaa
    Fish, Falk
    Sarfati, Patrice
    Haick, Hossam
    SENSORS AND ACTUATORS B-CHEMICAL, 2020, 304 (304):
  • [6] Peripheral airway inflammation assessed by fractional measurement of the exhaled breath temperature is a leading feature of asthma
    Hristova, D.
    Kralimarkova, T. Z.
    Popov, T. A.
    ALLERGY, 2018, 73 : 664 - 664
  • [7] EXHALED BREATH TEMPERATURE MEASUREMENT: INFLUENCE OF CIRCADIAN RHYTHM
    Carpagnano, G. E.
    Lacedonia, D.
    Malerba, M.
    Martinelli, D.
    Cotugno, G.
    Foschino-Barbaro, M. P.
    JOURNAL OF BIOLOGICAL REGULATORS AND HOMEOSTATIC AGENTS, 2017, 31 (01): : 229 - 235
  • [8] Exhaled Breath Temperature Measurement in Allergic Respiratory Disease
    Villarreal Gonzalez, Rosalaura
    Gonzalez-Diaz, Sandra N.
    Arias-Cruz, Alfredo
    Macias-Weinmann, Alejandra
    Elizondo-Villarreal, Barbara
    Elizabeth de Lira-Quezada, Cindy
    Ivett Guzman-Avilan, Rosa
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2019, 143 (02) : AB10 - AB10
  • [9] Development of an Individual Device for Exhaled Breath Temperature Measurement
    Popov, Todor A.
    Kralimarkova, Tanya Z.
    Tzachev, Christo T.
    Dunev, Stefan S.
    Dimitrov, Vasil D.
    Gill, Jas
    IEEE SENSORS JOURNAL, 2010, 10 (01) : 110 - 113
  • [10] Measurement of exhaled breath temperature in science and clinical practice
    Popov, T. A.
    Kralimarkova, T. Z.
    Dimitrov, V. D.
    BREATHE, 2012, 8 (03) : 187 - 192