Double-clad photonic crystal fibre for two-photon microscopy

被引:0
|
作者
Xu, Huizhen [1 ]
Wang, Xiulin [1 ]
Peng, Dongqing [1 ]
机构
[1] Jimei Univ, Sch Sci, Xiamen, Peoples R China
关键词
Photonic crystal fibre; numerical aperture; two-photon microscopy; double-clad; OPTICAL-FIBER; DEEP;
D O I
10.1080/09500340.2024.2319747
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Miniaturized and head-mountable scanning nonlinear fibre-optic microscopy offers an exciting opportunity for the visualization of brain activity on freely walking mice. One challenge in the creation of such miniaturized microscopes is the design of optical fibres capable of delivering ultrashort pulses without distortion and collecting fluorescence simultaneously and efficiently. A double-clad photonic crystal fibre (DCPCF) with 37-cell air holes arranged in hexagonal lattice in core is proposed. The full vector finite element method (FEM) is used for numerical analysis. Nearly zero dispersion of -0.34 ps/nm/km at 920 nm wavelength is finally achieved. The single-mode core with an NA of 0.53 at 920 nm wavelength is used to deliver the femtosecond excitation beam and the inner cladding with an NA of 0.54 at 532 nm is used to collect the two-photon fluorescence signal. The nearly zero dispersion, high NA and low nonlinearity will be beneficial to promote its application in two-photon microscopy.
引用
收藏
页码:673 / 680
页数:8
相关论文
共 50 条
  • [11] Estimation of Rayleigh scattering loss in a double-clad photonic crystal fiber
    Kovacevic, Milan S.
    Kuzmanovic, Ljubica
    Djordjevich, Alexandar
    OPTICAL AND QUANTUM ELECTRONICS, 2018, 50 (05)
  • [12] Visible double-clad upconversion fibre laser
    Zellmer, H
    Plamann, K
    Huber, G
    Scheife, H
    Tunnermann, A
    ELECTRONICS LETTERS, 1998, 34 (06) : 565 - 567
  • [13] Two-photon laser scanning fluorescence microscopy using photonic crystal fiber
    McConnell, G
    Riis, E
    JOURNAL OF BIOMEDICAL OPTICS, 2004, 9 (05) : 922 - 927
  • [14] Estimation of the Maximum Output Power of Double-Clad Photonic Crystal Fiber Laser
    Chen Yue-E
    Wang Yong
    Qu Xi-Long
    CHINESE PHYSICS LETTERS, 2012, 29 (07)
  • [15] Double-clad hollow core photonic crystal fiber for coherent Raman endoscope
    Brustlein, Sophie
    Berto, Pascal
    Hostein, Richard
    Ferrand, Patrick
    Billaudeau, Cyrille
    Marguet, Didier
    Muir, Alistair
    Knight, Jonathan
    Rigneault, Herve
    OPTICS EXPRESS, 2011, 19 (13): : 12562 - 12568
  • [16] Development of a double-clad photonic-crystal-fiber based scanning microscope
    Ye, JY
    Myaing, MT
    Thomas, TP
    Majoros, I
    Koltyar, A
    Baker, JR
    Wadsworth, WJ
    Bouwmans, G
    Knight, JC
    Russell, PSJ
    Norris, TB
    Multiphoton Microscopy in the Biomedical Sciences V, 2005, 5700 : 23 - 27
  • [17] Design and study on characteristics of double-clad photonic crystal fibers with flattened dispersion
    Lei, Jingli
    Li, Xiaoxiao
    Wang, Daobin
    Wu, Gang
    Liu, Yanjun
    Hou, Shanglin
    Guangxue Xuebao/Acta Optica Sinica, 2015, 35
  • [18] Mutual injection-locking of two individual double-clad fibre lasers
    Liu, Y.
    Chen, Y.
    Xu, L.
    Zhen, R.
    Wang, X.
    Lu, Y.
    Guo, Y.
    Wan, Q.
    Wang, H.
    Sun, B.
    ELECTRONICS LETTERS, 2009, 45 (08) : 399 - U25
  • [19] Rectangular double-clad fibre laser with two-end-bundled pump
    Liu, A
    Song, J
    Kamatani, K
    Ueda, K
    ELECTRONICS LETTERS, 1996, 32 (18) : 1673 - 1674
  • [20] Photonic crystal fibre enables short-wavelength two-photon laser scanning fluorescence microscopy with fura-2
    McConnell, G
    Riis, E
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (20): : 4757 - 4763