Effect of perfluoropropane (C3F8 ) versus sulfurhexafluoride (SF6) tamponades on the retinal microvasculature after macular hole surgery

被引:0
|
作者
Kaya, Seda Cevik [1 ]
Tekin, Kemal [2 ]
Celik, Selda [2 ]
Teke, Mehmet Yasin [2 ]
机构
[1] Ulucanlar Eye Training & Res Hosp, Dept Ophthalmol, Kale St :59, TR-06240 Ankara, Turkiye
[2] Ulucanlar Eye Training & Res Hosp, Dept Retinal Dis, Ankara, Turkiye
关键词
Macular hole; Optical coherence tomography angiography; Pars plana vitrectomy; Retinal microvasculature; Vitreoretinal surgery; COHERENCE TOMOGRAPHY ANGIOGRAPHY; FOVEAL AVASCULAR ZONE; SURGICAL-MANAGEMENT; VITREOUS SURGERY; VITRECTOMY; FEATURES; OUTCOMES; OCT;
D O I
10.1016/j.pdpdt.2023.103847
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To determine the effects of C3F8 and SF6 gasses by using optical coherence tomography angiography (OCTA) in patients with surgically closed idiopathic full-thickness macular holes (FTMH).Methods: A prospective, comparative study, in which 38 eyes of 38 patients with an idiopathic FTMH were studied. Twenty patients were randomized to the C3F8 group and 18 patients to the SF6 group. All patients underwent pars plana vitrectomy, internal limiting membrane peeling with 14 % C3F8 or 20 % SF6 gasses. The superficial capillary plexus (SCP) and deep capillary plexus (DCP) vessel densities (VD), foveal avascular zone (FAZ) area in SCP, the choriocapillaris flow area; and subfoveal choroidal thickness (SFCT) were examined at preoperative and postoperative first- and third-month controls using OCTA.Results: When the changes in the FAZ, SFCT, SCP and DCP VDs were compared, no significant differences were found between the groups (p>0.05 for all). It was determined that the 1-mm radius flow area increases in the C3F8 group at the first and third months after the surgery were significantly higher than in the SF6 group (p<0.05). A significant gain was observed in the BCVA values compared to their preoperative values for both groups; however any differences between the C3F8 and SF6 groups in terms of BCVA were not detected in this study.Conclusion: This is the first report to compare the effects of C3F8 and SF6 gasses on idiopathic FTMH surgery by using OCTA. C3F8 and SF6 gasses may have similar effect on the remodeling process of vascular tissues.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Arc Erosion Behavior of Cu/Ti3SiC2 Cathodes in c-C4F8 Gas as a Substitute for SF6 Gas
    Liu, Zhuhan
    Feng, Yi
    Jiang, Ningyuan
    Zhou, Zijue
    Wang, Fei
    Li, Xinchao
    Yu, Miao
    JOURNAL OF ELECTRONIC MATERIALS, 2023, 52 (11) : 7818 - 7832
  • [42] Insulation Characteristics of c-C4F8-N2 and CF3I-N2 Mixtures as Possible Substitutes for SF6
    Zhao, Hu
    Li, Xingwen
    Lin, Hui
    IEEE TRANSACTIONS ON POWER DELIVERY, 2017, 32 (01) : 254 - 262
  • [43] Arc Erosion Behavior of Cu/Ti3SiC2 Cathodes in c-C4F8 Gas as a Substitute for SF6 Gas
    Zhuhan Liu
    Yi Feng
    Ningyuan Jiang
    Zijue Zhou
    Fei Wang
    Xinchao Li
    Miao Yu
    Journal of Electronic Materials, 2023, 52 : 7818 - 7832
  • [44] EFFECT OF SF6 AND C4F8 FLOW RATE ON ETCHED SURFACE PROFILE AND GRASS FORMATION IN DEEP REACTIVE ION ETCHING PROCESS
    Sharma, Pallavi
    Pleil, Matthias
    Jackson, Nathan
    PROCEEDINGS OF ASME 2022 INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, IMECE2022, VOL 9, 2022,
  • [45] To study the efficacy of air descemetopexy in the management of various types of Descemet membrane detachment based on anterior segment optical coherence tomography and to know the role of 14% C3F8, 20% SF6 in failed cases of air descemetopexy
    Singh, S. P.
    Singh, B. K.
    Singh, Vinod
    Singh, Kamaljeet
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2019, 47 : 37 - 37
  • [46] Inductively coupled plasma etching of ultra-shallow Si3N4 nanostructures using SF6/C4F8 chemistry
    Sang, Bruno Lee
    Gour, Marie-Josee
    Jaouad, Abdelatif
    Ecoffey, Serge
    Darnon, Maxime
    Sadani, Benattou
    Souifi, Abdelkader
    Drouin, Dominique
    MICROELECTRONIC ENGINEERING, 2015, 141 : 68 - 71
  • [47] DETERMINATION OF ABSOLUTE RATE CONSTANTS FOR CAPTURE OF THERMAL ELECTRONS BY CCL4, SF6, C4F8, C7F14, N2F4 AND NF3
    MOTHES, KG
    SCHINDLE.RN
    BERICHTE DER BUNSEN-GESELLSCHAFT FUR PHYSIKALISCHE CHEMIE, 1971, 75 (09): : 938 - &
  • [48] MEASUREMENTS OF NEGATIVE-ION DENSITIES IN 13.56-MHZ RF PLASMAS OF CF4, C2F6, CHF3, AND C3F8 USING MICROWAVE RESONANCE AND THE PHOTODETACHMENT EFFECT
    HAVERLAG, M
    KONO, A
    PASSCHIER, D
    KROESEN, GMW
    GOEDHEER, WJ
    DEHOOG, FJ
    JOURNAL OF APPLIED PHYSICS, 1991, 70 (07) : 3472 - 3480
  • [49] Kinematic viscosity and speed of sound in gaseous CO, CO2, SiF4, SF6, C4F8, and NH3 from 220 K to 375 K and pressures up to 3.4 MPa
    Estrada-Alexanders, Andres F.
    Hurly, John J.
    JOURNAL OF CHEMICAL THERMODYNAMICS, 2008, 40 (02): : 193 - 202
  • [50] Behaviors of electron and negative-ion densities in low-pressure high-density inductively coupled plasmas of SF6, NF3, CF4, and C4F8 gases diluted with Ar
    Kono, A
    Konishi, M
    Kato, K
    THIN SOLID FILMS, 2002, 407 (1-2) : 198 - 203