Axial compression behaviour of concrete filled double skin steel tube columns anchored with orbicular rings: Experimental and numerical approach

被引:1
|
作者
Singh, Harpreet [1 ]
Tiwary, Aditya Kumar [1 ,2 ]
机构
[1] Chandigarh Univ, Univ Inst Engn, Dept Civil Engn, Mohali, India
[2] Chandigarh Univ, Univ Inst Engn, Dept Civil Engn, NH-05,Ludhiana Chandigarh State Hwy,Sahibzada Ajit, Mohali 140413, India
关键词
thin-walled concrete-filled double skin steel tube section; orbicular anchored CFDST; stiffened CFDST; ultimate load capacity; confinement effect; load-strain behavior; composite action; TUBULAR STUB COLUMNS; SHS INNER; MECHANICAL-BEHAVIOR; NONLINEAR-ANALYSIS; CHS OUTER; CFDST; PERFORMANCE; DESIGN; MODEL; STIFFENERS;
D O I
10.1177/13694332231205054
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Double-skin tube column sections have been used extensively in recent years. These sections are composed of two adjacent, coaxially spaced steel casings, and the space in the middle of them is occupied with concrete. These CFDST columns behave similarly to CFST sections but are more rigid and have a lesser self-weight. The behavior of a novel type of CFDST column, the orbicular anchored CFDST column, was assessed under axial compression in the current research. It comprises an inside and an outside steel tube with orbicular rings near the ends of the columns. The orbicular rings were positioned at various spots such as L/3, L/4, and L/5, and a wide range of tests were accomplished to evaluate the functionality of orbicular anchored CFDST columns in respect of maximum load-bearing capability, load-strain behavior, and load-deformation behavior. A FE model was developed and its accuracy was authenticated by comparing its findings with experimental results. Furthermore, a parametric investigation was carried out employing the authenticated FE model to examine the functioning of the proposed CFDST to variations in orbicular position, cross-sectional dimensions of rings, yield strength of orbicular ring, etc. The outcomes of the study indicated that orbicular anchored CFDST columns had 15% higher ultimate load capacity than unstiffened counterparts. The orbicular anchorage improved the ductile response and increased the axial stiffness of the CFDST column. Further, it was concluded that orbicular rings enhanced the constraining effect of external steel casing on sandwiched concrete and improved the composite action of CFDST specimens. The design formula to ascertain the load-bearing ability of columns was also developed and can be employed amid preliminary designs of proposed column sections.
引用
收藏
页码:2830 / 2861
页数:32
相关论文
共 50 条
  • [41] Axial behaviour of slender concrete-filled steel tube square columns strengthened with square concrete-filled steel tube jackets
    Zhu, Tao
    Liang, Hongjun
    Lu, Yiyan
    Li, Weijie
    Zhang, Hong
    ADVANCES IN STRUCTURAL ENGINEERING, 2020, 23 (06) : 1074 - 1086
  • [42] Study on restraint coefficient of the stirrups-stiffened square concrete filled double-skin steel tube axial compression stub columns
    Ding, Faxing
    Lu, Deren
    Lai, Zhichao
    Liu, Xuemei
    STRUCTURES, 2024, 60
  • [43] Experimental behaviour of circular concrete filled steel tube columns and design specifications
    Ekmekyapar, Talha
    Al-Eliwi, Baraa J. M.
    THIN-WALLED STRUCTURES, 2016, 105 : 220 - 230
  • [44] Axial Compression Behaviour of Hybrid Double-Skin Tubular Columns Filled with Rubcrete
    Youssf, Osama
    Hassanli, Reza
    Mills, Julie E.
    Yan Zhuge
    JOURNAL OF COMPOSITES SCIENCE, 2019, 3 (02):
  • [45] Experimental investigation of rubberised concrete-filled double skin square tubular columns under axial compression
    Elchalakani, Mohamed
    Hassanein, M. F.
    Karrech, Ali
    Yang, Bo
    ENGINEERING STRUCTURES, 2018, 171 : 730 - 746
  • [46] Axial behaviour of semi-lightweight aggregate concrete-filled steel tube columns - A DOE approach
    Abhilash, M.
    Jhanjhari, Sanyam
    Parthiban, P.
    Karthikeyan, J.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2019, 162
  • [47] Experimental and Theoretical Study of Concrete-Filled Steel Tube Columns Strengthened by FRP/Steel Strips Under Axial Compression
    Shichang Zhang
    Kunting Miao
    Yang Wei
    Xiaoming Xu
    Bin Luo
    Weizhou Shi
    International Journal of Concrete Structures and Materials, 17
  • [48] Axial compression performance of concrete-filled-steel tube flat columns with a large steel ratio
    Wang, Hanqin
    Xuan, Dianchun
    Jiang, Qing
    Huang, Junqi
    Chong, Xun
    STRUCTURES, 2024, 59
  • [49] Behaviour of polymer-filled-concrete-steel double-skin tubular columns under combined lateral impact and axial compression loading
    Wijesooriya, Kasun
    Mohotti, Damith
    Weerasinghe, Dakshitha
    Lee, Chi King
    STRUCTURES, 2023, 56
  • [50] Behavior of steel fiber reinforced concrete-filled steel tube columns under axial compression
    Lu, Yiyan
    Li, Na
    Li, Shan
    Liang, Hongjun
    CONSTRUCTION AND BUILDING MATERIALS, 2015, 95 : 74 - 85