Axial compression behaviour of concrete filled double skin steel tube columns anchored with orbicular rings: Experimental and numerical approach

被引:1
|
作者
Singh, Harpreet [1 ]
Tiwary, Aditya Kumar [1 ,2 ]
机构
[1] Chandigarh Univ, Univ Inst Engn, Dept Civil Engn, Mohali, India
[2] Chandigarh Univ, Univ Inst Engn, Dept Civil Engn, NH-05,Ludhiana Chandigarh State Hwy,Sahibzada Ajit, Mohali 140413, India
关键词
thin-walled concrete-filled double skin steel tube section; orbicular anchored CFDST; stiffened CFDST; ultimate load capacity; confinement effect; load-strain behavior; composite action; TUBULAR STUB COLUMNS; SHS INNER; MECHANICAL-BEHAVIOR; NONLINEAR-ANALYSIS; CHS OUTER; CFDST; PERFORMANCE; DESIGN; MODEL; STIFFENERS;
D O I
10.1177/13694332231205054
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Double-skin tube column sections have been used extensively in recent years. These sections are composed of two adjacent, coaxially spaced steel casings, and the space in the middle of them is occupied with concrete. These CFDST columns behave similarly to CFST sections but are more rigid and have a lesser self-weight. The behavior of a novel type of CFDST column, the orbicular anchored CFDST column, was assessed under axial compression in the current research. It comprises an inside and an outside steel tube with orbicular rings near the ends of the columns. The orbicular rings were positioned at various spots such as L/3, L/4, and L/5, and a wide range of tests were accomplished to evaluate the functionality of orbicular anchored CFDST columns in respect of maximum load-bearing capability, load-strain behavior, and load-deformation behavior. A FE model was developed and its accuracy was authenticated by comparing its findings with experimental results. Furthermore, a parametric investigation was carried out employing the authenticated FE model to examine the functioning of the proposed CFDST to variations in orbicular position, cross-sectional dimensions of rings, yield strength of orbicular ring, etc. The outcomes of the study indicated that orbicular anchored CFDST columns had 15% higher ultimate load capacity than unstiffened counterparts. The orbicular anchorage improved the ductile response and increased the axial stiffness of the CFDST column. Further, it was concluded that orbicular rings enhanced the constraining effect of external steel casing on sandwiched concrete and improved the composite action of CFDST specimens. The design formula to ascertain the load-bearing ability of columns was also developed and can be employed amid preliminary designs of proposed column sections.
引用
收藏
页码:2830 / 2861
页数:32
相关论文
共 50 条
  • [22] Experimental and numerical studies on mechanical behavior of stiffened concrete-filled square steel tube columns subjected to axial compression
    Sun, Yanyan
    Xu, Jing
    Zuo, Gong
    STRUCTURAL CONCRETE, 2023, 24 (01) : 802 - 817
  • [23] Experimental and numerical study of L-shaped irregularly concrete-filled steel tube columns under axial compression and eccentric compression
    Liu, Wang -Hui
    Wang, Xiong
    Guo, Yan-Lin
    Tian, Zi-Hao
    Li, Jing-Yuan
    Bai, Wen-Hua
    JOURNAL OF BUILDING ENGINEERING, 2024, 84
  • [24] Behaviour and design of hollow and concrete-filled spiral welded steel tube columns subjected to axial compression
    Aslani, Farhad
    Uy, Brian
    Hur, James
    Carino, Paolo
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2017, 128 : 261 - 288
  • [25] Bearing Capacity of Concrete-Filled Double Skin Stub Columns with Square outer Stainless Steel tube Under Axial Compression
    Tang H.
    Liao J.
    Liu R.
    Hu X.
    Xinan Jiaotong Daxue Xuebao/Journal of Southwest Jiaotong University, 2023, 58 (02): : 421 - 429
  • [26] Behavior of concrete-filled steel tube reinforced concrete columns subjected to axial compression
    Yao, Guohuang
    Li, Yongjin
    Liao, Feiyu
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2013, 34 (05): : 114 - 121
  • [27] Axial compression behavior of CFRP-confined square concrete-filled double skin tube stub columns with stainless steel outer tube
    Tang, Hongyuan
    Wang, Huixiang
    Liu, Ruizhong
    Zou, Xue
    Jia, Yigang
    OCEAN ENGINEERING, 2022, 266
  • [28] Compression behavior of the concrete-filled double skin steel tube columns under hydrostatic pressure: Experimental and modeling study
    Aghamaleki, Seyed Tohid Nemati
    Naghipour, Morteza
    Amiri, Javad Vaseghi
    Nematzadeh, Mahdi
    STRUCTURES, 2023, 58
  • [29] A new creep model for concrete filled steel tube columns under axial compression
    Zhang, Dianjie
    Wang, Yuanfeng
    Lei, Yang
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2010, 43 (SUPPL. 2): : 246 - 251
  • [30] Numerical investigation on circular concrete-filled double skin steel tube columns under torsion
    Lu, Guo-Bing
    Zhou, Xu-Hong
    Wang, Yu-Hang
    Deng, Xiao-Wei
    Bai, Yong-Tao
    Zhu, Rong-Hua
    STRUCTURES, 2022, 37 : 17 - 31