XEN®-63 Compared to XEN®-45 Gel Stents to Reduce Intraocular Pressure in Glaucoma

被引:6
|
作者
Evers, Charlotte [1 ]
Boehringer, Daniel [1 ]
Kallee, Sara [1 ]
Keye, Philip [1 ]
Philippin, Heiko [1 ,2 ]
Piotrowski, Timothy [1 ]
Reinhard, Thomas [1 ]
Luebke, Jan [1 ]
机构
[1] Univ Freiburg, Fac Med, Eye Ctr, Med Ctr, D-79106 Freiburg, Germany
[2] London Sch Hyg & Trop Med, Fac Infect & Trop Dis, Int Ctr Eye Hlth, London WC1E 7HT, England
关键词
XEN (R)-63 gel stent; glaucoma; bleb revision; OUTCOMES; IMPLANT; PHACOEMULSIFICATION; EFFICACY; SURGERY; SAFETY;
D O I
10.3390/jcm12155043
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The XEN (R) gel stent reduces intraocular pressure (IOP) in glaucoma. XEN (R)-45 is widely used; the newer XEN (R)-63 has a larger lumen targeting potentially lower IOP outcomes. We retrospectively compared the first 15 XEN (R)-63 cases to 15 matched XEN (R)-45 controls. With a preoperative IOP of 18.1 +/- 3.9 mmHg (mean +/- SD) and a final IOP of 9.1 +/- 2.0 mmHg, XEN (R)-63 implantation resulted in an IOP reduction of 44.6 +/- 16.5%. Similarly, with a preoperative IOP of 18.3 +/- 4.5 mmHg and a final IOP of 10.3 +/- 2.1 mmHg, XEN (R)-45 implantation resulted in an IOP reduction of 40.1 +/- 17.2%. The median follow-up period was 204 days (range 78-338 days) for the XEN (R)-63 group and 386 days (range 99-1688 days) for the XEN (R)-45 group. In total, 5/15 eyes of each group underwent open conjunctival bleb revision within the period of observation. Three eyes of the XEN (R)-63 group had secondary glaucoma surgery. One eye in the XEN (R)-63 group and three eyes in the XEN (R)-45 group required a restart of antiglaucomatous medication. In conclusion, both stents effectively lower IOP and medication. XEN (R)-63 achieved a slightly lower IOP over a short follow-up. Complication and revision rates were similar.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] One year efficacy and safety of inferior implantation of Xen 45® Gel Stent in refractory glaucoma
    Bastelica, P.
    Amatu, J. -B.
    Buffault, J.
    Majoulet, A.
    Labbe, A.
    Baudouin, C.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2024, 47 (08):
  • [22] Safety and Efficacy of Ab Interno XEN 45 Gel Stent in Patients with Glaucoma and High Myopia
    Sacchi, Matteo
    Fea, Antonio M.
    Monsellato, Gianluca
    Tagliabue, Elena
    Villani, Edoardo
    Ranno, Stefano
    Nucci, Paolo
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (07)
  • [23] Glaucoma medical treatment as a predictor of XEN45 subconjunctival gel implant hypotensive efficacy
    Carmen Méndez-Hernández
    Carlos Palomino-Bautista
    Ramón Torres-Imaz
    Pilar Peña-Urbina
    Lucía Perucho-González
    Julián García-Feijoo
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2023, 261 : 521 - 533
  • [24] Standalone XEN45 Gel Stent implantation versus combined XEN45-phacoemulsification in the treatment of open angle glaucoma—a systematic review and meta-analysis
    Sheng Yang Lim
    Bjorn Kaijun Betzler
    Leonard Wei Leon Yip
    Syril Dorairaj
    Bryan Chin Hou Ang
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2021, 259 : 3209 - 3219
  • [25] Intraocular Pressure and Medication Changes Associated with Xen Gel Stent: A Systematic Review of the Literature
    Panarelli, Joseph F.
    Vera, Vanessa
    Sheybani, Arsham
    Radcliffe, Nathan
    Fiscella, Richard
    Francis, Brian A.
    Smith, Oluwatosin U.
    Noecker, Robert J.
    CLINICAL OPHTHALMOLOGY, 2023, 17 : 25 - 46
  • [26] A Case of Refractory Neovascular Glaucoma Treated With a XEN 45 Implant
    Tailor, Rajen
    Lalias, Theodoros
    JOURNAL OF GLAUCOMA, 2018, 27 (10) : 929 - 930
  • [27] XEN-45 collagen implant for the treatment of uveitic glaucoma
    Sng, Chelvin C. A.
    Wang, Jing
    Hau, Scott
    Htoon, Hla Myint
    Barton, Keith
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2018, 46 (04): : 339 - 345
  • [28] Trends in adverse events reported with the use of Xen gel stents
    Shaikh, Anam K.
    Choudhry, Hassaam
    Guttikonda, Sri
    Sanchez, Alexandra
    Kumarapuram, Siddhant
    Mahajan, Jasmine
    Sangani, Roshun
    Khouri, Albert S.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [29] Relationship between the location of the XEN® stent glaucoma implant (with respect to the Tenon capsule) and the intraocular pressure
    Figueroa-Vercellino, J. P.
    Peraza-Nieves, J. E.
    Milla, E.
    Pazos, M.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2019, 42 (04): : 421 - 422
  • [30] A case of mitomycin C toxicity after XEN gel stent implantation with the XEN air technique in a glaucoma patient
    Joon Young Baeg
    Han Sol Choi
    Si Hyung Lee
    BMC Ophthalmology, 23