Visible and near-infrared spectroscopic determination of sugarcane chlorophyll content using a modified wavelength selection method for multivariate calibration

被引:10
|
作者
Ong, Pauline [1 ,2 ]
Jian, Jinbao [1 ,3 ]
Li, Xiuhua [4 ,5 ]
Yin, Jianghua [1 ]
Ma, Guodong [1 ]
机构
[1] Guangxi Minzu Univ, Coll Math & Phys, Ctr Appl Math Guangxi, Nanning 530006, Peoples R China
[2] Univ Tun Hussein Onn Malaysia, Fac Mech & Mfg Engn, Batu Pahat 86400, Johor, Malaysia
[3] Guangxi Minzu Univ, Guangxi Key Lab Hybrid Computat & IC Design Anal, Nanning 530006, Peoples R China
[4] Guangxi Univ, Sch Elect Engn, Nanning 530005, Peoples R China
[5] Guangxi Univ, Guangxi Key Lab Sugarcane Biol, Nanning 530005, Peoples R China
关键词
Chlorophyll; Gaussian process regression; Partial least squares regression; Sugarcane; Wavelength selection; VARIABLE SELECTION; PREDICTION;
D O I
10.1016/j.saa.2023.123477
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Spectroscopy in the visible and near-infrared region (Vis-NIR) region has proven to be an effective technique for quantifying the chlorophyll contents of plants, which serves as an important indicator of their photosynthetic rate and health status. However, the Vis-NIR spectroscopy analysis confronts a significant challenge concerning the existence of spectral variations and interferences induced by diverse factors. Hence, the selection of characteristic wavelengths plays a crucial role in Vis-NIR spectroscopy analysis. In this study, a novel wavelength selection approach known as the modified regression coefficient (MRC) selection method was introduced to enhance the diagnostic accuracy of chlorophyll content in sugarcane leaves. Experimental data comprising spectral reflectance measurements (220-1400 nm) were collected from sugarcane leaf samples at different growth stages, including seedling, tillering, and jointing, and the corresponding chlorophyll contents were measured. The proposed MRC method was employed to select optimal wavelengths for analysis, and subsequent partial least squares regression (PLSR) and Gaussian process regression (GPR) models were developed to Spectrochimica Spectroscopy establish the relationship between the selected wavelengths and the measured chlorophyll contents. In comparison to full-spectrum modelling and other commonly employed wavelength selection techniques, the proposed simplified MRC-GPR model, utilizing a subset of 291 selected wavelengths, demonstrated superior performance. The MRC-GPR model achieved higher coefficient of determination of 0.9665 and 0.8659, and lower root mean squared error of 1.7624 and 3.2029, for calibration set and prediction set, respectively. Results showed that the GPR model, a nonlinear regression approach, outperformed the PLSR model.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Determination of Alcohol Content in Beers of Different Styles Based on Portable Near-Infrared Spectroscopy and Multivariate Calibration
    da Costa Fulgencio, Ana Carolina
    Passos Resende, Glaucimar Alex
    Fontoura Teixeira, Marden Claret
    Botelho, Bruno Goncalves
    Sena, Marcelo Martins
    FOOD ANALYTICAL METHODS, 2022, 15 (02) : 307 - 316
  • [32] Reflectance Near-Infrared Spectroscopic Method with a Chemometric Technique Using Partial Least Squares Multivariate Calibration for Simultaneous Determination of Chondroitin, Glucosamine, and Ascorbic Acid
    El-Gindy, Alaa
    Attia, Khalid Abdel-Salam
    Nassar, Mohammad Wafaa
    El-Abasawy, Nasr M. A.
    Shoeib, Maisra Al-Shabrawi
    JOURNAL OF AOAC INTERNATIONAL, 2012, 95 (03) : 724 - 732
  • [33] Wavelength calibration of a dispersive near-infrared spectrometer using trichloromethane as a calibration standard
    Busch, KW
    Soyemi, O
    Rabbe, D
    Humphrey, K
    Dundee, B
    Busch, MA
    APPLIED SPECTROSCOPY, 2000, 54 (09) : 1321 - 1326
  • [34] NONDESTRUCTIVE TESTING OF SOLUBLE SOLIDS CONTENT IN CERASUS HUMILIS USING VISIBLE/NEAR-INFRARED SPECTROSCOPY COUPLED WITH WAVELENGTH SELECTION ALGORITHM
    Wang, Bin
    He, Junlin
    Zhang, Shujuan
    Li, Lili
    INMATEH-AGRICULTURAL ENGINEERING, 2020, 61 (02): : 251 - 262
  • [35] Simultaneous Wavelength Selection and Outlier Detection in Multivariate Regression of Near-Infrared Spectra
    Da Chen
    Xueguang Shao
    Bin Hu
    Qingde Su
    Analytical Sciences, 2005, 21 : 161 - 166
  • [36] Simultaneous wavelength selection and outlier detection in multivariate regression of near-infrared spectra
    Chen, D
    Shao, XG
    Hu, B
    Su, QD
    ANALYTICAL SCIENCES, 2005, 21 (02) : 161 - 166
  • [37] A three-stage wavelength selection algorithm for near-infrared spectroscopy calibration
    Feng, Xi-Yao
    Chen, Zheng-Guang
    Yi, Shu-Juan
    Wang, Peng-Hui
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2025, 324
  • [38] Blend uniformity end-point determination using near-infrared spectroscopy and multivariate calibration
    Sulub, Yusuf
    Konigsberger, Michele
    Cheney, James
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 55 (03) : 429 - 434
  • [39] COMPARISON OF MULTIVARIATE METHODS BASED ON LATENT VECTORS AND METHODS BASED ON WAVELENGTH SELECTION FOR THE ANALYSIS OF NEAR-INFRARED SPECTROSCOPIC DATA
    JOUANRIMBAUD, D
    WALCZAK, B
    MASSART, DL
    LAST, IR
    PREBBLE, KA
    ANALYTICA CHIMICA ACTA, 1995, 304 (03) : 285 - 295
  • [40] CLOSED-LOOP MOVING WINDOWS WAVELENGTH SELECTION METHOD WITH APPLICATION TO NEAR-INFRARED SPECTROSCOPIC ANALYSIS
    Pang, Liwen
    Chen, Jiemei
    Pan, Tao
    2019 10TH WORKSHOP ON HYPERSPECTRAL IMAGING AND SIGNAL PROCESSING - EVOLUTION IN REMOTE SENSING (WHISPERS), 2019,