Clinical Study of a Physician Modified Y-Type Iliac Branch Device (PMYIBD) in the Endovascular Repair of Abdominal Aortic Aneurysms to Preserve the Internal Iliac Artery

被引:0
|
作者
Zhao, Zihe [1 ,2 ]
Jin, Yi [1 ]
Fu, Dongsheng [1 ]
Liu, Chen [1 ]
Qiao, Tong [1 ]
Li, Xiaoqiang [1 ]
Gao, Xia [2 ,4 ]
Liu, Zhao [1 ,3 ]
机构
[1] Nanjing Univ, Affiliated Drum Tower Hosp, Dept Vasc Surg, Med Sch, Nanjing, Peoples R China
[2] Nanjing Univ, Affiliated Drum Tower Hosp, Dept Otolaryngol Head & Neck Surg, Jiangsu Prov Key Med Discipline Lab,Med Sch, Nanjing, Peoples R China
[3] Nanjing Univ, Affiliated Drum Tower Hosp, Dept Vasc Surg, Med Sch, 321 Zhongshan Rd, Nanjing 210008, Peoples R China
[4] Nanjing Univ, Affiliated Drum Tower Hosp, Dept Otolaryngol Head & Neck Surg, Jiangsu Prov Key Med Discipline Lab,Med Sch, 321 Zhongshan Rd, Nanjing 210008, Peoples R China
关键词
abdominal artery aneurysm; abdominal aortic dissection; internal iliac artery; branch devices; GRAFTS;
D O I
10.1177/15266028231165185
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objectives: To report the method and curative effect of using a physician modified Y-type iliac branch device (PMYIBD) to preserve the internal iliac artery during the endovascular repair of abdominal aortic aneurysms. Methods: From September 2018 to April 2022, 24 patients with abdominal aortic aneurysms or dissecting aneurysms, including 19 true aneurysms and 5 dissecting aneurysms involving the common iliac artery were treated in our department. The average age was (65.3 +/- 7.6) years. All patients underwent preoperative evaluation by enhanced computed tomography. Combined with intraoperative angiography, a Y-type stent graft was prepared during surgery to perform endovascular repair of abdominal aortic aneurysms. Results: All operations were successfully completed. The average operative duration was (224.8 +/- 44.1) minutes. A total of 24 internal iliac arteries were reconstructed. The average follow-up time was (27.1 +/- 13.5) months. During the followup, there was no expansion of aneurysm cavity, no endoleak or stent displacement, and no death occurred in all patients. Discussion: The physician-modified Y-type iliac branched device (PMYIBD) provides an effective method for full-cavity repair. It has a wide range of indications and convenience. According to follow-up results, the early and mid-term had good curative effects; however, the long-term effects require further follow-up. Conclusion: The modified Y-type IBD technique is safe and effective for aortic diseases involving internal iliac artery especially with complex anatomy.
引用
收藏
页码:1150 / 1157
页数:8
相关论文
共 50 条
  • [41] The fate of small aneurysms of the internal iliac artery following proximal ligation in abdominal aortic aneurysm repair
    Unno, N
    Kaneko, H
    Uchiyama, T
    Yamamoto, N
    Nakamura, S
    SURGERY TODAY, 2000, 30 (09) : 791 - 794
  • [42] Clinical outcomes after internal iliac artery embolization prior to endovascular aortic aneurysm repair
    Kang, Jihee
    Chung, Byeoung-Hoon
    Hyun, Dong-Ho
    Park, Yang-Jin
    Kim, Dong-Ik
    INTERNATIONAL ANGIOLOGY, 2020, 39 (04) : 323 - 329
  • [43] Endovascular repair of abdominal aortic aneurysms with concomitant common iliac artery aneurysm: Outcome analysis of the EUROSTAR experience
    Hobo, Roel
    Sybrandy, Johannes E. M.
    Harris, Peter L.
    Buth, Jacob
    JOURNAL OF ENDOVASCULAR THERAPY, 2008, 15 (01) : 12 - 22
  • [44] Clinical outcomes after internal iliac artery embolization prior to endovascular aortic aneurysm repair
    Keun-Myoung Park
    Shin-Seok Yang
    Young-Wook Kim
    Kwang Bo Park
    Hong Suk Park
    Young-Soo Do
    Dong-Ik Kim
    Surgery Today, 2014, 44 : 472 - 477
  • [46] Clinical outcomes after internal iliac artery embolization prior to endovascular aortic aneurysm repair
    Park, Keun-Myoung
    Yang, Shin-Seok
    Kim, Young-Wook
    Park, Kwang Bo
    Park, Hong Suk
    Do, Young-Soo
    Kim, Dong-Ik
    SURGERY TODAY, 2014, 44 (03) : 472 - 477
  • [47] Failure to preserve the internal iliac artery during abdominal aortic aneurysm repair is associated with mortality and ischemic complications
    Bae, Miju
    Lee, Chung Won
    Chung, Sung Woon
    Huh, Up
    Jin, Moran
    Kim, Min Su
    JOURNAL OF VASCULAR SURGERY, 2022, 76 (01) : 122 - 131
  • [48] Complete Ipsilateral Femoral Approach Using an Iliac Branch Device to Preserve a Sole Internal Iliac Artery After Aortic Stent-Graft Placement
    Riess, Henrik Christian
    Koelbel, Tilo
    Diener, Holger
    Heidemann, Franziska
    Debus, E. Sebastian
    Rohlffs, Fiona
    Tsilimparis, Nikolaos
    JOURNAL OF ENDOVASCULAR THERAPY, 2016, 23 (05) : 800 - 802
  • [49] Successful endovascular repair of iliac artery aneurysms with unsuitable anatomy by combining unibody bifurcated endograft and iliac branch systems to preserve hypogastric artery blood flow: a report of two cases
    Akagi, Daisuke
    Murase, Kai
    JOURNAL OF CARDIOTHORACIC SURGERY, 2022, 17 (01)
  • [50] Successful endovascular repair of iliac artery aneurysms with unsuitable anatomy by combining unibody bifurcated endograft and iliac branch systems to preserve hypogastric artery blood flow: a report of two cases
    Daisuke Akagi
    Kai Murase
    Journal of Cardiothoracic Surgery, 17