Clinical Study of a Physician Modified Y-Type Iliac Branch Device (PMYIBD) in the Endovascular Repair of Abdominal Aortic Aneurysms to Preserve the Internal Iliac Artery

被引:0
|
作者
Zhao, Zihe [1 ,2 ]
Jin, Yi [1 ]
Fu, Dongsheng [1 ]
Liu, Chen [1 ]
Qiao, Tong [1 ]
Li, Xiaoqiang [1 ]
Gao, Xia [2 ,4 ]
Liu, Zhao [1 ,3 ]
机构
[1] Nanjing Univ, Affiliated Drum Tower Hosp, Dept Vasc Surg, Med Sch, Nanjing, Peoples R China
[2] Nanjing Univ, Affiliated Drum Tower Hosp, Dept Otolaryngol Head & Neck Surg, Jiangsu Prov Key Med Discipline Lab,Med Sch, Nanjing, Peoples R China
[3] Nanjing Univ, Affiliated Drum Tower Hosp, Dept Vasc Surg, Med Sch, 321 Zhongshan Rd, Nanjing 210008, Peoples R China
[4] Nanjing Univ, Affiliated Drum Tower Hosp, Dept Otolaryngol Head & Neck Surg, Jiangsu Prov Key Med Discipline Lab,Med Sch, 321 Zhongshan Rd, Nanjing 210008, Peoples R China
关键词
abdominal artery aneurysm; abdominal aortic dissection; internal iliac artery; branch devices; GRAFTS;
D O I
10.1177/15266028231165185
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objectives: To report the method and curative effect of using a physician modified Y-type iliac branch device (PMYIBD) to preserve the internal iliac artery during the endovascular repair of abdominal aortic aneurysms. Methods: From September 2018 to April 2022, 24 patients with abdominal aortic aneurysms or dissecting aneurysms, including 19 true aneurysms and 5 dissecting aneurysms involving the common iliac artery were treated in our department. The average age was (65.3 +/- 7.6) years. All patients underwent preoperative evaluation by enhanced computed tomography. Combined with intraoperative angiography, a Y-type stent graft was prepared during surgery to perform endovascular repair of abdominal aortic aneurysms. Results: All operations were successfully completed. The average operative duration was (224.8 +/- 44.1) minutes. A total of 24 internal iliac arteries were reconstructed. The average follow-up time was (27.1 +/- 13.5) months. During the followup, there was no expansion of aneurysm cavity, no endoleak or stent displacement, and no death occurred in all patients. Discussion: The physician-modified Y-type iliac branched device (PMYIBD) provides an effective method for full-cavity repair. It has a wide range of indications and convenience. According to follow-up results, the early and mid-term had good curative effects; however, the long-term effects require further follow-up. Conclusion: The modified Y-type IBD technique is safe and effective for aortic diseases involving internal iliac artery especially with complex anatomy.
引用
收藏
页码:1150 / 1157
页数:8
相关论文
共 50 条
  • [31] Type IV Ehlers Danlos: Abdominal Aortic Rupture After Endovascular Repair of Common Iliac Artery Aneurysms
    Tronconi, Sofia
    Galvao, Natalia
    Husemann, Fabio Menezes
    Guillaumon, Ana Terezinha
    JOURNAL OF VASCULAR SURGERY, 2024, 79 (04) : 19S - 19S
  • [32] Endovascular repair of residual iliac artery aneurysms following surgery for ruptured abdominal aortic aneurysm
    Panayiotopoulos, YP
    Sandison, AJP
    Reidy, JF
    Adam, A
    Taylor, PR
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1996, 12 (04) : 482 - 486
  • [33] Outcomes for concomitant common iliac artery aneurysms after endovascular abdominal aortic aneurysm repair
    Bannazadeh, Mohsen
    Jenkins, Christina
    Forsyth, Andrew
    Kramer, Jason
    Aggarwal, Ankur
    Somerset, Amy E.
    Bove, Paul G.
    Long, Graham W.
    JOURNAL OF VASCULAR SURGERY, 2017, 66 (05) : 1390 - 1397
  • [34] Treating patients with abdominal aortic aneurysm with endovascular repair and the crossover chimney technique in the internal iliac artery to protect the unilateral internal iliac artery
    Guo, Xi
    Li, Peng
    Liu, Guang-Rui
    Huang, Xiao-Yong
    Huang, Lian-Jun
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2015, 8 (11): : 21737 - 21745
  • [35] The Use of an Iliac Branch Device: Single-Center Study of Endovascular Preservation of Internal Iliac Artery Flow
    Lee, Hyeseung
    Lee, Jeong-min
    Cho, Soongu
    Hong, JungUi
    JOURNAL OF THE KOREAN SOCIETY OF RADIOLOGY, 2023, 84 (06): : 1339 - 1349
  • [36] Outcome after Interruption or Preservation of Internal Iliac Artery Flow During Endovascular Repair of Abdominal Aorto-iliac Aneurysms
    Kouvelos, G. N.
    Katsargyris, A.
    Antoniou, G. A.
    Oikonomou, K.
    Verhoeven, E. L. G.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2016, 52 (05) : 621 - 634
  • [37] Physician-Modified Reversed Iliac Branch Device to Prevent Spinal Cord Ischemia in an Urgent Branched Endovascular Aortic Repair
    Malik, Karolina
    Koelbel, Tilo
    Grandi, Alessandro
    Torrealba, Jose
    Rohlffs, Fiona
    Panuccio, Giuseppe
    JOURNAL OF ENDOVASCULAR THERAPY, 2024,
  • [38] The combination of iliac branch device with parallel stent graft to preserve bilateral internal iliac arteries in a patient with infrarenal abdominal aortic and bilateral common iliac artery aneurysm with short common iliac lengths: A case report
    Yu, Sz-Han
    Wu, I-Hui
    SAGE OPEN MEDICAL CASE REPORTS, 2024, 12
  • [39] Preservation of pelvic circulation with hypogastric artery bypass in endovascular repair of abdominal aortic aneurysm with bilateral iliac artery aneurysms
    Unno, Naoki
    Inuzuka, Kazunori
    Yamamoto, Naoto
    Sagara, Daisuke
    Suzuki, Minoru
    Konno, Hiroyuki
    JOURNAL OF VASCULAR SURGERY, 2006, 44 (06) : 1170 - 1175
  • [40] The Fate of Small Aneurysms of the Internal Iliac Artery Following Proximal Ligation in Abdominal Aortic Aneurysm Repair
    Naoki Unno
    Hiroshi Kaneko
    Takashi Uchiyama
    Naoto Yamamoto
    Satoshi Nakamura
    Surgery Today, 2000, 30 : 791 - 794